background image

29

695_20161212

Technology Description:

Floating, solar powered, circulation equipment for potable water tanks and reservoirs. 

Day/night operation on solar only by utilizing a battery to store excess daytime power 

for nighttime operation.

Minimum Access Opening/ 

Machine Size/Weight:

Machine can be installed through a 3 feet by 3 feet (92cm by 92 cm) opening.

Assembled machine is 16 feet (5 m)  in diameter and weighs 800 pounds (360 kg).

Shipping Size/Weight:

Machine can be crated and shipped in a 87 inch (2.2 m) wide X 87 inch (2.2 m) long 

X 65 inch (1.7 m) high crate, estimated shipping weight is 1500 pounds (680 kg).  

Hose lengths greater than 40 ft (6 m) and pole mount solar panel stands may require 

additional crating. 

Materials of Construction

NSF/ANSI Standard 61:

316 stainless steel construction. Foam-filled high-density polyethylene (HDPE) floats. 

Thermoplastic rubber intake hose. HDPE strainer. 

The SB10000PW is NSF/ANSI 

Standard 61 Certified.

Drive System:

High torque, direct drive (no gearbox), low voltage brushless D.C. motor.

Power Supply/Control System:

PV Solar Panels, Battery and Electronic Controller are mounted on rack outside.

PV Solar Panels 

3 X 80-watt photovoltaic solar panels. Battery storage for day/night operation.

Electronic Controller

Digital solid-state controller, mounted in weather-tight (NEMA 4X) enclosure with 

internally fused disconnect. SCADA output through RS-232 serial communication 

(Modbus RTU), DB9 male connection point inside enclosure.  Wireless options 

available, not included.

Wiring

Corrosion-resistant industrial cord with molded watertight connectors that are indexed 

to prevent improper wiring. Low voltage in reservoir, less than 36 VDC.

Rotating Assembly:

Removable assembly with easy access to impeller and impeller shaft.

Flotation System:

Three floats in triangular pattern with total buoyancy of 1,450 pounds (660 kg).

Fluid Intake Assembly:

Intake hose bolted to bottom of machine structural assembly.

Hose System

10 to 40 feet (3 to 30 m)available in 36-inch diameter (92cm) X 10, 15, or 20 feet (3m, 

4.5m, or 6m) sections.

Intake Type

Horizontal plate with 12-inch (32cm) openings.

Intake Depth Adjustment

15 feet (4.5m) of field adjustment with three SS chains connected to hose coupling.

Intake Assembly at Bottom of

Hose

48-inch (1.2m) diameter plate rests just above floor of reservoir.  Horizontal flow into 

the intake hose is through 12-inch (32cm) openings above the plate. 

        Intake Depth Adjustment

Self-adjusting for all depths up to 40 feet (12.2m).

Chlorine Boosting

Chlorine boost hose, accessible at top of reservoir spans down and connects to intake 

for fast chlorine dispersion during in-reservoir boosting.

Minimum Water Depth:

At depths below 5 feet (1.5m), the impeller will be out of the water and the machine will 

stop circulating water. No damage to machine if ran dry in shallow water.

Accessories Available:

1) Portable Chlorine Boost System, (2) LED RPM Indicator (3) Supplemental Power Kit, 

and (4) Wireless SCADA Kit

Life/Maintenance/Warranty:

Expect 25-year life, minimal maintenance. Limited 2-year parts and labor warranty.  

Limited 25 year photovoltaic module manufacturer performance warranty and 10 year 

motor warranty.

NSF/ANSI Std 61

Potable Water Core Units

SB10000PW FEATURES

Patent Pending 

Subject to change without notice.

Medora Corporation • 3225 Hwy 22 • Dickinson, ND 58601

+1 866 437 8076 • Ph +1 701 225 4495 • Fax +1 701 225 0002 • www.medoraco.com

© 2017 Medora Corp.

Содержание SolarBee SB10000PW

Страница 1: ...eneral Electrical Schematic Troubleshooting Specifications Model Drawing Overall Machine Dimensions Parts Identification Warranty Statement 1 4 5 14 23 26 29 30 31 32 33 507_20161212 Medora Corp 3225...

Страница 2: ...1 Carefully read safety information when you see any safety symbols...

Страница 3: ...Y FLOAT ASSEMBLY PINS OR BOLTS WHILE THE SOLARBEE IS FLOATING IN THE WATER THE SOLARBEE MUST BE RESTING ON THE GROUND OR SAFELY SUPPORTED TO RELIEVE THE FORCES ON THE FLOAT ASSEMBLY STRUCTURES PRIOR T...

Страница 4: ...OSHA Protect Yourself SolarBee Inc insists that you comply with all relative OSHA and local regulations while installing and performing any maintenance to the SolarBee circulation equipment Key OSHA...

Страница 5: ...best technology available for your application Extensive design efforts have been made to make the SolarBee easy to maintain with high quality long life parts If at any time you feel that your SolarB...

Страница 6: ...ification and surface renewal The SolarBee obtains all the energy it needs from the sun Its solar panels provide power to the battery which energizes the drive system s controls and motor The new Tech...

Страница 7: ...ules which individually connect to an external enclosure that contains a digital controller and the battery The PV modules generally are placed on a low profile stand The PV modules are positioned so...

Страница 8: ...Card similar to that of a digital camera s memory stick SCADA outputs offering machine operation parameters reside within the digital controller Please contact SolarBee if you are interested in receiv...

Страница 9: ...uipment should only be used for the inputs or outputs that they are labeled and designed for If any of the leads going into the electronic controller are disconnected be sure when re connecting to pla...

Страница 10: ...e any routine maintenance A drive shaft extends through the bottom center of the housing Shaft Coupling The shaft coupling connects the brushless motor drive shaft to the impeller shaft The shaft coup...

Страница 11: ...lag indicator is fixed to the shaft and used as a visual indicator of the impeller shaft s rotational speed The impeller blades are welded around a hub that is securely fastened to the impeller shaft...

Страница 12: ...e distributor dish is set approximately 2 inch to 2 5 inch 5 0 cm to 6 5 cm below the surface of the water to achieve best flow results The distributor dish depth is set by rotating the turnbuckles lo...

Страница 13: ...se will cause the lip of the distributor dish to lower The turnbuckle and float arm structure components are constructed with robust stainless steel materials allowing the SolarBee to operate in sever...

Страница 14: ...d before fixing the ends the turnbuckle will have limited adjustment Floats The SolarBee has 3 floats made from high density Polyethylene The floats are filled with a Polystyrene closed cell foam for...

Страница 15: ...her necessary means to perform routine checkups and field adjustment procedures on the SolarBee It is extremely important that safety comes first every time the SolarBee is inspected or having mainten...

Страница 16: ...d on the roof of the tank or reservoir If your tank is ground storage standpipe hydropillar pedesphere or other style elevated tank please follow the necessary OSHA regulations in regards to Fall Prot...

Страница 17: ...tor starting with ZERO ONE TWO etc for a time of less than or equal to 1 minute and at least 20 seconds This step is easier with two people one counting revolutions and the other keeping track of the...

Страница 18: ...he impeller STEP 4 Observe and clean any debris located down in the dish where the impeller rests Place the debris into a garbage bag and remove from pond to prevent it from going through SolarBee aga...

Страница 19: ...the dish level is too deep or not deep enough at the three locations where each float arm extends out from the machine This can be done using a tape measure by approximating the height of a nickel or...

Страница 20: ...ssible This will reduce some drag when towing the SolarBee to its position in the reservoir STEP 4 Towing the SolarBee can be done one of two ways The first way is to hook a chain or towing line aroun...

Страница 21: ...EP 3 With the SolarBee off unscrew the battery lead from the battery terminal STEP 4 Slide the battery out of the front of the Low Profile Stand IMPORTANT NOTE The battery weighs approximately 140lbs...

Страница 22: ...e than a few days The On Off switch is located in the SolarBee electronic controller mounted to the pv module stand STEP 2 Cover the entire SolarBee including the hose and intake assembly using a heav...

Страница 23: ...e should not be coiled or draped over the SolarBee Reposition the electrical cord and injection hose so they do not get tangled on any objects STEP 7 The SolarBee is now ready for the tank to be fille...

Страница 24: ...and Service Center Medora Corp 3225 Hwy 22 Dickinson ND 58601 1 866 437 8076 1 701 225 4495 Fax 1 701 225 0002 OUTSIDE OF RESERVOIR OUTSIDE OF RESERVOIR Inside Low Profile INSIDE OF RESERVOIR PV MODU...

Страница 25: ...24 Maintenance and Field Adjustment...

Страница 26: ...gital controller and from the motor if needed Complete Power Up Procedure NO TOOLS REQUIRED STEP 1 2 Connect the motor controller to the motor and to the digital controller Be certain steps 1 2 have b...

Страница 27: ...nd record the blinking LEDs color and of blinks in succession and solid green LED off or on 3 Using the LED label match your blink observations to the corresponding indication Use the information on t...

Страница 28: ...inking Red Anti Jam Routine machine is operating on a jam removal sequence triggered by high current Check for plugging only after disconnecting power If power is not removed first machine may begin t...

Страница 29: ...28 SolarBee Troubleshooting...

Страница 30: ...o prevent improper wiring Low voltage in reservoir less than 36 VDC Rotating Assembly Removable assembly with easy access to impeller and impeller shaft Flotation System Three floats in triangular pat...

Страница 31: ...30 MODEL SB10000PW 203_20160513 2016 Medora Corp Main Office and Service Center 1 866 437 8076 medoraco com 3225 Highway 22 Dickinson ND 58601...

Страница 32: ...E INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF MEDORA CORPORATION ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF MEDORA CORPORATION IS PROHIBITED Dimension D...

Страница 33: ...aco com 3225 Highway 22 Dickinson ND 58601 NO PART DESCRIPTION 01 22281100 ROTATING ASSEMBLY 02 22010027 LOWER COUPLING SLEEVE 03 14283095 SOLAR PANEL WIRED 04 18260225 FLOAT ARM ASSEMBLY 05 18265000...

Страница 34: ...labor Parts that are determined by Medora Corporation to be defective in material or workmanship under normal use during the one year warranty period will be repaired or replaced Shipping charges are...

Страница 35: ...years to come SERIAL NO Medora Corporation 3225 Hwy 22 Dickinson ND 58601 1 866 437 8076 1 701 225 4495 Fax 1 701 225 0002 www medoraco com MODEL NO V Medora Corporation 3225 Hwy 22 Dickinson ND 58601...

Страница 36: ...rvoirs SolarBee s specialized Service and Installation Technicians are trained in Confined Space Fall Protection and other related subjects as required by OSHA to perform the necessary work to install...

Отзывы: