MEDLITE HOMECARE BED PARTS LIST 

 

 

 

   Medline Home Care Bed  

 

 

 

Part 

Number Description 

Bed 

Style* 

Item 

Number Quantity

1 Foot 

Spring 

Assembly 

All 

MDR630054 

1/EA 

2 Head 

Spring 

Assembly 

All 

MDR630114 

1/EA 

3 Foot 

Board 

Assembly 

S/M 

MDR630014 

1/EA 

  

Foot Board Assembly 

MDR630314 

1/EA 

4 Headboard 

Assembly 

All 

MDR630024 

1/EA 

Casters- 2 locking, 2 non-locking 

All 

MDR620034 

4/Bx 

Drive Shaft (Two Pieces) 

All 

MDR620124 

1/EA 

7 Emergency 

Crank 

Handle 

All 

MDR620104 

1/EA 

8 Motor 

Guard 

Tube 

All 

MDR620044 

1/EA 

Pendant With Cord (Two Motor) 

MDR630094 

1/EA 

  

Pendant With Cord (Three Motor) 

MDR630154 

1/EA 

10 

 

Junction Box  (2 motor) 
Junction Box  (3 motor) 

MDR630084 
MDR630144 

1/EA 
1/EA 

11 

Motor/ Actuator for Foot Spring 

S/F 

MDR630074 

1/EA 

  

Handle/ Shaft Assembly for Foot Spring 

MDR620224 

1/EA 

12 

Motor/ Actuator for Head Spring 

S/F 

MDR630064 

1/EA 

  

Handle/ Shaft Assembly for Head Spring 

MDR620214 

1/EA 

13 

Hi-Low Motor Assembly 

MDR630164 

1/EA 

14 

Gear Box for Head Board 

All 

MDR620025 

1/EA 

15 

Gear Box For Footboard With Handle 

S/M 

MDR620015 

1/EA 

  

Gear Box For Footboard No Handle 

MDR630035 

1/EA 

16 

Handle Assembly For Hi-Low 

S/M 

MDR620085 

1/EA 

17 

Quick Release Lock for Motor 

All 

MDR620175 

4/Set 

18 

Fasteners Set for Head Spring Motor 

All 

MDR620005 

1 Set 

19 

Extension Tube of Head Motor Assembly 

S/F 

MDR630065 

1/EA 

  

Extension Tube, Handle/ Shaft Assembly 

MDR620075 

1/EA 

20 Screw, 

J-Box 

S/F 

MDR620095 

2/Set 

21 

Fasteners Set for Head Spring Motor 

All 

MDR620055 

1 Set 

22 

Screw with Lock Nut for Motor Guard Tube

All 

MDR620045 

4/Set 

23 

Springs for head section 

All 

MDR620105 

62/CS 

24 

Springs for foot section 

All 

MDR620115 

12/CS 

25 

Mesh Grid for head section 

All 

MDR620125 

204/EA 

26 

Mesh Grid for foot section 

All 

MDR620135 

259/EA 

27 Engaging 

Clip 

All 

MDR620145 

6/BX 

28 Hi-Low 

Motor 

Screw F 

MDR630165 

2/Set 

29 Gear 

Box 

Screw 

All 

MDR620155 

4/Set 

30 Panel 

for 

Headboard 

All 

MDR630244 

2/Set 

31 

Panel for Footboard 

All 

MDR620254 

2/Set 

32 

Composite Inserts for Casters 

All 

MDR620185 

4/Set 

Bed Style 

 F= Full-Electric Bed: MDR107003L 

 

 

 

 

S= Semi- Electric Bed: DR107002L 

 

 

 

             

M= Manual Bed: MDR107000P 

 

 

 

 

 

 

 

 

Содержание MDR107000P

Страница 1: ...MDR107003L Semi Electric Bed Model MDR107002L Manual Bed Model MDR107000P DEALER This manual must be given to the user of the Medline Home Care Bed USER Please read this manual completely for warning...

Страница 2: ...ic 2 Motor 1 Crank Manual 3 Crank Model Number MDR107003L MDR107002L MDR107000P Head Ends Min 28 5 Max 35 75 Min 28 5 Max 35 75 Min 28 5 Max 35 75 Foot Ends Min 26 Max 33 Min 26 Max 33 Min 26 Max 33 F...

Страница 3: ...E AT 1 800 MEDLINE BEFORE USE OTHERWISE SERIOUS BODILY INJURY OR PRODUCT DAMAGE MAY OCCUR A QUALIFIED TECHNICIAN MUST PERFORM ANY REPAIR OR CHANGE TO THIS BED OR SERIOUS INJURY MAY OCCUR TECHNICIANS D...

Страница 4: ...mes 13 Connecting the Spring Fabric 14 Installing the Casters 15 Installing the Headboard and Footboard 16 Patient Hand Control 17 Adjusting Connecting the Head Spring Pull Tube 18 Installing the Cent...

Страница 5: ...5 MEDLITE HOMECARE BED PARTS DIAGRAM Full Electric Bed See Page 7 for List of Terms Head Spring Assembly Foot Spring Assembly...

Страница 6: ...ear Box for Head Board All MDR620025 1 EA 15 Gear Box For Footboard With Handle S M MDR620015 1 EA Gear Box For Footboard No Handle F MDR630035 1 EA 16 Handle Assembly For Hi Low S M MDR620085 1 EA 17...

Страница 7: ...r further instructions Do not use near explosive gases Possible fire hazard when used with oxygen administering equipment other than nasal or masked type Use ONLY mask or nasal type oxygen administeri...

Страница 8: ...head and foot boards BEFORE use Ensure that the pendant and power cords are routed and secured properly so the cords do not become entangled pinched and or severed during operation of the electric bed...

Страница 9: ...nd thickness size or density of the mattress could cause entrapment Use ONLY authorized Medline replacement parts For semi electric and full electric beds always remove the manual crank before perform...

Страница 10: ...rom the junction box DO NOT operate the bed unless the ground wire is attached to frame Weight Limitations The TOTAL weight limit of the Medline Home Care Bed including accessories mattress occupant a...

Страница 11: ...nd Semi Electric Models include motors a junction box and Electrical cord already attached Manual Model includes handle cranks on the frame 1 Hand Pendant Control and Cord Full and Semi Electric Model...

Страница 12: ...sadjustment of motors which may cause frame damage DO NOT attempt to operate the bed controls until assembly of the entire bed is complete as damage to bed components or personal injury may occur Bed...

Страница 13: ...ngle to one another 5 Hook the bottom head spring center mounting latches to the bottom foot spring center mounting rivets see Figure 2a 6 Hook the top head spring center mounting latches to the top f...

Страница 14: ...g up lift the head spring section upward to give slack to the fabric Connect the spring fabric together with the links provided 2 Hook together all the links to the spring fabric 3 Lower the head spri...

Страница 15: ...shaft of the caster into the caster socket of each bed leg Ensure the stem is fully inserted into the socket See Figure 4 4 To prevent excess movement of the bed during assembly lock each of the two l...

Страница 16: ...as close to the head frame as possible 2 Raise the head frame until the rivets on the corner plates of the head frame fit into the corner locks on the headboard The headboard may need to be tilted bac...

Страница 17: ...e hand pendant cable is routed in a way such that it will not become entangled or pinched when the bed is adjusted Do not place the pendant hand control under or between objects This may unintentional...

Страница 18: ...th a telescoping tube Type 1 Please locate which head spring extension tube your bed contains and use the instructions regarding that type of extension tube Cotter Pin Grommet Washer Clevis Pin Headsp...

Страница 19: ...serting the clevis pin into the lift arm slot Reconnect the grommet and washer and secure the cotter pin Figure 9B Type 2 Extension tube attachment 1 To provide up and down movement of the head sectio...

Страница 20: ...ype of bed being used and engage the spring button into the proper positioning hole as follows a For semi electric and manual beds engage the spring button into the first hole position in the outer sh...

Страница 21: ...ents are securely installed BED ASSEMBLY Junction Box Connections 1 To insert cords into the junction box line the cords up with the appropriate receptacle on the junction box and push in until fully...

Страница 22: ...ase the button permit a slight pause and then activate the next operation NEVER operate the bed if the pendant hand control or the power cord is damaged Before placing the bed into use test it by oper...

Страница 23: ...ed Hi Lo Turning the crank clockwise will cause each bed function to raise Turning the crank counterclockwise will cause each bed function to lower Caution After using any hand crank be sure to push t...

Страница 24: ...ot be washed down with a pressure washers or steam cleaner Doing so can result in problems with the electrical system 3 Inspect bed components for any exposed metal To prevent rusting Medline recommen...

Страница 25: ...to ensure there is no damage or excessive wear 8 Inspect all bed motions headspring raises lowers properly foot spring raises lowers properly bed height raises lowers properly 9 Ensure all electrical...

Страница 26: ...headboard or foot board raises when Hi Lo adjustment is made The pin in the middle of the center drive shaft has fallen out allowing the shaft to collapse and disengage Replace the pin and reconnect t...

Страница 27: ...semblies of this Split Spring Home Care Bed These two motors are controlled by a Hand Pendant that is used by the patient or care giver to adjust the bed to either a comfortable or functional position...

Отзывы: