background image

4   

SPECIFICATIONS      

Items

HCS70004P, HCS70004G, HCS70004BL, 

HCS70004C, HCS70004DP, HCS70004

Current

120V/60HZ

Power consumptiont

180 VA Max

Nebulize Cup

#30503

Operation air pressure

9 - 16 Psi (62 - 110 kPa)

Max air pressure

35 - 50 Psi (241 - 345 kPa)

Operation Air Flow

5.0 - 8.0 Lpm

Nebulizer rate

≥ 0.18mL/min (2% saline)

Noise level

≤ 55 dB

Operation R.H.

30 - 85% RH

Operation temperature

10 - 40 °C (50 - 104 °F)

Storage R.H.

30 - 85% RH

Storage temperature

-20 - 70 °C (-4 - 158 °F)

Dimensions(L x W x H)

150 x 140 x 90 mm

Weight

1.2 kg

(1).  Conditions may vary based on altitude above sea level, barometric  

       pressure air temperature. Specifications subject to change without

       notice. 

(2).  Nebulizer specifications may vary with the kind of medication being 

       used and its viscosity.

(3).  For electromagnetic compatibility the standards are based as follow:    

       IEC/EN 60601-1-2. 

(4).

 

 Protection against electric shock is classified as Type II.

(5).  Degree of protection against electric shock is classified as Type BF. 

(6).  Equipment not suitable for use in the presence of a flammable anesthetic  

 

mixture with air, oxygen, or nitrous oxide.

Содержание HCS70004

Страница 1: ...HCS70004P HCS70004G HCS70004C HCS70004BL HCS70004DP HCS70004 AEROMIST Instruction Manual COLORS NEBULIZER COMPRESSOR KIT...

Страница 2: ...1 TABLE OF CONTENTS IEC Symbols 2 Important Safeguards 2 Introduction 3 Speci cations 4 Description 5 Operation Instructions 6 Cleaning 7 Maintenance 7 Trouble Shooting Guide 8 Warranty 9...

Страница 3: ...Any other use is not recommended 5 Do not untwist the jet nebulizer during operation 6 Do not pour more than 10 mL of solution into the jet nebulizer Danger To Reduce the risk of electrocution 7 Alwa...

Страница 4: ...e such as a bed or couch where the air opening may be blocked 9 Avoid operating in wet or damp locations 10 Unplug the unit before lling the nebulizer Warning To reduce the risk of infection Cleaning...

Страница 5: ...4 158 F Dimensions L x W x H 150 x 140 x 90 mm Weight 1 2 kg 1 Conditions may vary based on altitude above sea level barometric pressure air temperature Specifications subject to change without notice...

Страница 6: ...5 DESCRIPTION Power Switch Air Outlet Connector Filter Cap Power Cord Compressor Mouthpiece reservoir tubing Jet Nebulizer Cap Baffle Jet Nebulizer Chamber Air Inlet Connector Tubing Foam Filters...

Страница 7: ...the jet nebulizer cap If an aerosol mask is used connect the bottom of mask to the top of jet nebulizer cap 7 Connect tubing to jet nebulizer air inlet connector 8 Turn the compressor on by pressing p...

Страница 8: ...bulizer cap chamber and baffle for 30 minutes in the solution Remove from solution and let air dry 5 There is no need to clean the tubing If necessary wipe the surface regularly CAUTION The jet nebuli...

Страница 9: ...t is properly connected The mist does not come out from the jet nebulizer aerosol output reduced low 1 Incorrect amount of medication in the jet nebulizer 2 Tubing disconnected 3 The jet nebulizer is...

Страница 10: ...is warranty Shipping charges if any shall be paid by the purchaser Note There is no other express warranty Implied warranties including those of merchantability and fitness for a particular purpose ar...

Отзывы: