background image

8     FCEALTMAXX   (PIC-xxxxx) 

Revision: 01/09/17

PACkAGING/hANDLING

RECEIVING

It is imperative that all shipments are inspected within 5 days in order to make a freight claim 
for any concealed damage.
1.  Count cartons before signing shipping papers.
2.  Compare the number of cartons shipped with the number actually received.
3.  Visually inspect all cartons for any damage.
4.  If number of packages shipped and received do not match up or if there is any damage to 

carton, note on freight bill and have driver sign acknowledging the claim and notify your 
Medline sales rep or Medline Customer Service (1-800-MEDLINE).

UNPACkING

CAUTION:

 The bed is extremely heavy; unpack with two or more people.

1.  Remove bands and top
2.  With at least 

TWO

 people, remove the bed from the carton by lifting underlying and 

rotating frame of bed so the casters are facing down. Place it on level ground next to the 
carton.

 ** If at this point, you discover concealed damage, immediately contact Medline Customer
 Service and take photographs to document the damage for the freight claim.
3.  Inspect plug and cord for any cuts or damage. If there isn’t any damage, plug in the bed and 

elevate the bed deck to a comfortable working height. 

4.  Cut the cable ties only holding bed deck sections to the bed frame, being careful not to 

damage cords or cables. 

DO NOT

 cut all cable ties from the bed. Cable ties are needed to 

hold bed wiring in place.

5.  Insert the wall guard into the head section H-frame using a rubber mallet if necessary. The 

wall guard includes C clips that allow you to extend the wall guard out and hold it in place.  
This allows for additional distance from the wall.

            Wall Guard Fully Inserted                              Wall Guard Extended for added distance

Содержание Alterra MAXX

Страница 1: ...OPERATION AND MAINTENANCE MANUAL Alterra MAXX Long Term Care Bed FCEALTMAXX This product is not made with natural rubber latex Packaging Handling Instructions see Page 8...

Страница 2: ...Page 7 LOCATING THE SERIAL NUMBER Page 7 PACKAGING AND HANDLING Page 8 INSTALLING OPTIONAL HEAD AND FOOTBOARDS Page 9 INSTALLING OPTIONAL ASSIST RAILS Page 10 BED OPERATION Page 12 ELECTRONICS Page 1...

Страница 3: ...reduce entrapment risk is ultimately the responsibility of the bed user and the healthcare facility It is strongly recommended that all personnel involved with hospital bed system maintenance service...

Страница 4: ...ns Key zones of the bed Dimensions Gaps within the rail Zone 1 120 mm 4 3 4 Under the rail between rail supports or next to a single rail support Zone 2 120 mm 4 3 4 Between rail and mattress Zone 3 1...

Страница 5: ...e gases Possible fire hazard when used with oxygen administering equipment other than nasal or masked types When administering oxygen with nasal or mask equipment oxygen or air tubing MUST be routed a...

Страница 6: ...or caregiver When using side rails excessive side pressure can cause the rails to deform or break DO NOT USE side rails as handles to move the bed NEVER permit more than 1 person in or on bed at any...

Страница 7: ...ght 7 3 4 Maximum Bed Deck Height 30 1 4 Maximum Safe Working Load 600 LBS Maximum Back Angle 70 Degrees 3 Maximum Knee Angle 28 Degrees 3 Trendelenburg Reverse Trendelenburg Angle 10 Degrees 2 Bed El...

Страница 8: ...m the carton by lifting underlying and rotating frame of bed so the casters are facing down Place it on level ground next to the carton If at this point you discover concealed damage immediately conta...

Страница 9: ...through all four holes 5 Slide the L brackets into the mounting tubes on the head end of the bed The bracket should rest in place with the snap buttons 6 Fully tighten each mounting screw on the L br...

Страница 10: ...ions carefully and check that all hardware fasteners are properly installed and tight Failure to do so may result in unexpected movement of the rails and could result in patient or caregiver injury FC...

Страница 11: ...tified with universal icons The hand pendant comes with a soft hook on the back side for suspending the control on assist rails or headboards The hand pendant can be plugged into either side of the be...

Страница 12: ...be adjusted by rotating them clockwise or counter clockwise to ensure proper contact with floor Secure the individual locking casters CAUTION If all four casters are not locked swivel and wheel rotat...

Страница 13: ...connect AC power 2 Remove the control box cover by using a flat head screw driver Insert the screwdriver into the control box cover slot marked INSERT TO OPEN The control box cover should now slide aw...

Страница 14: ...n to the desired width CAUTION Prior to putting the bed in use ensure that each bed deck extension piece is locked in place and set to the same width in order to ensure for proper mattress support CAU...

Страница 15: ...extension piece is locked in place Caster Guides The Alterra MAXX is equipped with two swing down caster positioning guides located at the head end of the bed The caster positioning guides will keep...

Страница 16: ...uipped with a kickstand for holding up the head section of the bed for easy access to the power cord and bed control box NEVER use the kickstand while anyone is in the bed The kickstand is used for Ma...

Страница 17: ...h on check fuse box or try another wall outlet Verify bed power source outlet is adequate for bed electrical rating Has the power cord become loose from the control box Insert power cord fully into co...

Страница 18: ...x Insert actuator cord into another working port on the control box If actuator works on a dif ferent port of the control box Verify it is not a hand pen dant issue Replace the control box Bed is not...

Страница 19: ...injury The bed must be turned on its side before replacing actuators A minimum of two people are required to turn bed on its side Fully elevate the bed deck and head section before turning the bed on...

Страница 20: ...the hand pendant an additional 5 seconds after the bed has reached its lowest elevation 10 Test the bed by raising and lowering elevation NOTE When replacing head and foot actuators special care need...

Страница 21: ...1 4 FCEMAXX04 Brake Pads 4 5 FCEMAXX05 Wall Guard 1 6 FCEMAXX06 Frame Assem bly Foot 1 includes the break mecha nism pedal 9 FCEMAXX09 Deck Head 1 10 FCEMAXX10 Deck Thigh 1 11 FCEMAXX11 Deck Foot 1 1...

Страница 22: ...des includes the width and length exten sion pieces Not Shown FCEMAXX16 Mounting Rods Side Rail 8 Not Shown FCEMAXX17 C Clip Mounting Rod 24 Not Shown FCEMAXX18 Width extension release spring 16 Not S...

Страница 23: ...r Head 1 Not Shown FCEMAXX26 Actuator Foot 1 Not Shown FCEMAXX27 Actuator Hi Low 2 Not Shown FCEMAXX28 Battery Backup 1 Not Shown FCEMAXX29 Lights LED Under bed 2 Not Shown FCEMAXX30 Hand Pendant 5 fu...

Страница 24: ...isinfecting the Bed 1 WARNING Unplug the power cord before cleaning or performing maintenance on the bed 2 Wipe the bed down with disinfectant and allow the bed to dry completely before use Mechanical...

Страница 25: ...or excessive wear 3 Ensure all plugs are fully plugged in and free of damage 4 Ensure all cords are properly routed with cable ties and free of moving parts 5 Check all bed functions a Head raises an...

Страница 26: ...MAINTENANCE SCHEDULE FCEALTMAXX Serial Date Inspection Maintenance Cleaning Initials Notes...

Страница 27: ......

Страница 28: ...d or repair Installation and freight costs for replaced or repaired items remain the responsibility of the Customer This warranty does not cover failure due to negligence accident deliberate abuse nor...

Отзывы: