6 FCEALTMAXX (PIC-xxxxx)
|
Revision: 01/09/17
SAFETy SUMMARy
AND OPERATING INFORMATION
• After installation and before use, ensure all attached hardware is securely tightened
• Hand pendant cord must be routed and secured properly to ensure cord does not become
entangled, pinched, or severed during normal bed operation.
• Keep all moving parts free from obstruction (i.e. blankets/sheets, heating blankets/pads,
tubing, wiring, etc.) or with any other products that use electric cords which could get
tangled around the bed, side rails or legs during operation of bed.
• The Alterra MAXX bed is equipped with
TWO
brakes locks; one on the head end of the
bed and one on the foot end. To operate the brake locks, press down on the red pedal
from either side of the bed. To unlock, press the green foot pedal from either side of the
bed.
ALWAYS
use the brake locks
EXCEPT
when moving the bed. Pads can be adjusted by
rotating them clockwise or counter-clockwise to ensure proper contact with floor.
• The side rails are
NOT
intended to be used as a patient restraint. If necessary, a physician
or healthcare professional should be consulted for other means of safe restraint.
• Be sure to fully lock side rails / assist bars in the fully up or down position. Failure to lock
the accessories may result in unintentional movement and injury to patient or caregiver.
• When using side rails, excessive side pressure can cause the rails to deform or break.
DO
NOT USE
side rails as handles to move the bed.
•
NEVER
permit more than 1 person in or on bed at any time. The safe working load for this
bed is rated at 600-lbs.
• Body weight should be evenly distributed over the surface of the bed.
• A person
SHOULD NOT
lay, sit or lean in such a way that his or her entire body weight is
placed only on the
RAISED
head or foot sections of the bed. This includes
ASSISITING
the
user in repositioning or transferring in or out of bed.
•
DO NOT ALTER THE PLUG ON THE ELECTRICAL CORD
. If the plug does not fit the existing
outlet, a correct outlet should be installed by a licensed electrician. NEVER operate the unit
if it has a damaged cord or plug.
•
UNPLUG
the power cord when performing any maintenance (including cleaning) on the
bed.
•
DO NOT
open or disassemble any factory sealed electronics. If these units are opened, the
warranty is void.
•
DO NOT
permit excessive prolong activation of the bed’s electrical function (duty cycle).
Exceeding the rated duty cycle of the electronics may cause damage or failure of bed
function.
(Duty Cycle = 10%: 2min on; 18min off)
• If all four bed casters are not locked, bed movement may occur with little or no resistance.
Always activate caster locks during patient transfer (patient movement in or out of the
bed) or use of the bed brake locks on the head and foot ends.
• The bed is intended for indoor use only.
•
DO NOT
cover the bed’s power cord with rugs, carpet, etc.