Place your palms above the device. The base of your 
palms should fit perfectly to a concave soft pad on top of 
the device. 

 

Start compressing- with each effective chest 
compression, BEATY will produce a sound. If no sound is 
heard follow instructions in section 6. Principles for 
effective chest compressions: 

o

 

Perpendicular alignment to the victim 

o

 

Locked elbows 

o

 

Chest compressions rate should be 120/min. 

o

 

Full chest recoil- after BEATY produces a sound, it is 
crucial to allow full chest recoil before next 
compression 

*If AED (Automatic External Defibrillator) is within reach use it 
according to instructions.

 

 

 

 

 

 

 

3. After use care/maintenance  

The device is categorized as ingress/international IP22 
according to IEC 60529  

3.1 Cleaning 

Use alcohol pad or wet wipe to clean the device. 
When cleaning, focus on the lower soft pad that 
comes in contact with 

Victim’s

 chest. Do not 

immerse in water or disinfectant solution as 
liquids of any type can damage the internal 
mechanism of the device

.

 

Содержание BEATY

Страница 1: ...Manual Manufactured by Medical Feedback Technologies Ltd Baruch Benaceraff 2 Rishon Lezion 7580537 Israel European representative Medes Limited 5 Beaumont Gate Shenley Hill Radlett Hertfordshire WD7...

Страница 2: ...with the device In case of any questions please contact our team It is strongly recommended that BEATY will be used by a person familiar with basic CPR principles visit our website www imbeaty com Use...

Страница 3: ...BEATY description 6 1 6 Symbols on the device 9 1 7 Delivered items 10 2 Using BEATY 10 2 1 Approaching the Victim 10 2 2 CPR using BEATY 10 3 After use care 11 3 1 Cleaning 11 3 2 Changing Battery 1...

Страница 4: ...nute and a depth of 5 6cm are suggested The main goal of effective chest compressions is restoration of blood flow to the brain thus prevention of permanent damage For untrained bystanders Hands only...

Страница 5: ...ing the user to perform effective chest compressions as suggested in the current AHA guidelines BEATY is placed between rescuer s palm and victim s chest while performing chest compressions BEATY give...

Страница 6: ...e to cardiac arrest NOTE BEATY is not the resuscitator It is only there to give an audio feedback during real time CPR that is performed according to guidelines 1 5 BEATY description Restoring effecti...

Страница 7: ...e made for easy attachment of the device allowing it to be within reach in case of medical crises Internal View 1 PCB containing BEATY S electrical components 2 3V lithium battery 3 Buzzer 4 Sensor Si...

Страница 8: ...ly pressure on the middle of the silicon adapter using both thumbs The device should easily come out from the other side See fig 2 next page 3 Use the device according to instructions Page 10 Section...

Страница 9: ...terials and components Waste Electrical and Electronic Equipment Directive Compliant Refer to User Instruction Guide Handle with care Manufacturer Manufacturing date Type BF applied part IP22 Ingress...

Страница 10: ...to give you an audible feedback regarding the effectiveness of routinely performed chest compressions 2 1 Approaching the Victim Secure your area move the victim and yourself away from hazardous facto...

Страница 11: ...rate should be 120 min o Full chest recoil after BEATY produces a sound it is crucial to allow full chest recoil before next compression If AED Automatic External Defibrillator is within reach use it...

Страница 12: ...nic CR2032 Sony CR2032 The list provided above is NOT a full list of UL approved batteries The list contains only several options For UL verification for your battery visit http database ul com cgibin...

Страница 13: ...t immerse Beaty in liquids as direct liquids can damage the device 4 2 Operation warnings and precautions CAUTION ROUTINE CHECKS AND AFTER USE CARE It is important to follow instructions regarding rou...

Страница 14: ...oting section continue CPR without the device WARNING EXTERNAL DAMAGE If external damage is seen do not use Beaty as it can result in user and victim injury as well as malfunction of the device WARNIN...

Страница 15: ...loud enough Not enough pressure applied Battery ran out Audio inlet Is covered by user s palm Broken device 1 Make sure audio inlet is not covered by hand 2 Make sure compressing perpendicularly to v...

Страница 16: ...ore pressure 4 Change battery as instructed in page 12 section 3 2 5 Contact our customer service 6 If no solution found remove BEATY and start compressing without the device 1 Check routinely for pro...

Страница 17: ...1 Check routinely for propriety see page 12 section 3 3 2 Follow storage and after use care instructions page 11 section 3 Discomfort in user s palm Improper location of palm over the device 1 Change...

Страница 18: ...ed electromagnetic fields IES 61000 4 3 10 0 V m 80 MHz 2 5 GHz 80 AM 1kHz Complies Item Specification Technical Data Power Requirements Rated input voltage 3V lithium coin battery Dimensions Width le...

Страница 19: ...g permanent damage CPR can triple chances of survival Q When should I use Beaty A Beaty should be used in every case where CPR is indicated As gauging the exact compression depth is almost impossible...

Страница 20: ...te is 100 120 min This can be estimated by following the rhythm of the song Stayin alive Bee Gees It is important to pay attention that pushing fast does not result in shallower depth Q How about othe...

Страница 21: ...designed to be used on victims 8 years old and above Q What if during CPR ribs are fractured A It is important to understand that deeper compressions increase survival rate During effective CPR skele...

Страница 22: ...time CPR on a real person As some manikins differ from human skeletal structure as well as chest recoil Beaty may not work properly on these manikins A Demonstration Only sample calibrated to a desire...

Отзывы: