![Medialon Showmaster Go Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/medialon/showmaster-go/showmaster-go_hardware-manual_1760587061.webp)
Showmaster Maintenance
Medialon Control System
p 59 of 80
User Reference Manual
M515-2 | 2020-May
scan [delay]
Scan for available Showmasters on the network with a delay expressed in milliseconds. Delay is
the total time scanning should take place.
connect
Open communication with the Showmaster connected to the COM port.
connect
Opens a connection to Showmaster named on the network. The default password is ‘
medialon
’.
Example:
A scan command is needed before using the connect command if using the network to connect
to the Showmaster.
disconnect
Closes the connection with Showmaster.
Example:
reboot
Sends a reboot command to Showmaster.
shutdown
Sends a shutdown command to Showmaster.
get conf
Gets Showmaster’s system configuration.
[msmrt] > connect
Showmaster
-
B038AE
medialon
[msmrt]
Connecting Showmaster
‘Showmaster-B038AE’
...
[msmrt]
Showmaster
‘Showmaster-B038AE’
connected
[msmrt]
> disconnect
[msmrt]
Disconnecting...
[msmrt]
Disconnected