16
105735
VENT-FREE NATURAL GAS HEATERS
BLUE-FLAME MBN20LB
™
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact Cans Unlimited, Incorporated’s
Technical Service Department at 1-800-
922-7407.
SPECIFICATIONS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
When Gas Quality Is Bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.
SERVICE HINTS
Btu (Variable)
10,000/20,000
Type Gas
Natural Only
Ignition
Piezo
Pressure Regulator Setting
3" W.C.
Inlet Gas Pressure (inches of water)
Maximum
10.5"
Minimum
5"
Dimensions, Inches (H x W x D)
Heater
23.5 x 18.5 x 8.0
Carton
26 x 20.5 x 9.63
Weight (pounds)
Heater
22
Shipping
27