Medallion MBN10LA Скачать руководство пользователя страница 5

5

105717

OWNER’S MANUAL

 WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space

or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
the methods described in the 

National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.

AIR FOR
COMBUSTION AND
VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space:

 Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between

the rooms.

1.

Determine the volume of the space (length x width x height).

Length x Width x Height = _______________ cu. ft. (volume of space)

Example:

 Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.

2.

Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

________________ (volume of space) 

÷

 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example:

 2560 cu. ft. (volume of space) 

÷

 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.

Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater

_____________ Btu/Hr

Gas water heater*

_____________ Btu/Hr

Gas furnace

_____________ Btu/Hr

Vented gas heater

_____________ Btu/Hr

Gas fireplace logs

_____________ Btu/Hr

Other gas appliances*  +

_____________ Btu/Hr

Total                             =

_____________ Btu/Hr

* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.

Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________________ Btu/Hr (maximum the space can support)

_________________ Btu/Hr (actual amount of Btu/Hr used)

Example:

51,200 Btu/Hr (maximum the space can support)

54,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.

You must provide additional fresh air. Your options are as follows:

A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-

ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.

C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.

Example:

Gas water heater

44,000

Btu/Hr

Vent-free heater  +

10,000

Btu/Hr

Total                   =

54,000

Btu/Hr

Continued

Содержание MBN10LA

Страница 1: ...service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damage Re fer to this manual for correct installation and ope...

Страница 2: ...o run properly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Fresh Air for Combus tion and Ventilation...

Страница 3: ...or Button 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bou...

Страница 4: ...rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to...

Страница 5: ...l fuel burning appliances in the space Vent free heater _____________ Btu Hr Gas water heater _____________ Btu Hr Gas furnace _____________ Btu Hr Vented gas heater _____________ Btu Hr Gas fireplace...

Страница 6: ...ls or ducts Figure 2 Ventilation Air from Inside Building WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appl...

Страница 7: ...rents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oi...

Страница 8: ...lls 1 4 to 1 2 thick Figure 7 Popping Open Anchor Wings For Thin Walls Figure 6 Folding Anchor Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place...

Страница 9: ...ible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance Installsedimenttrapinsupplylineasshown in Figure 12 Locate sediment trap where it is within reach...

Страница 10: ...heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct...

Страница 11: ...tton until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 13 through 15 Also contact a qualified service personorgassupplierforrepairs Un til repairs are made light pilot...

Страница 12: ...circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleaning due to excessiv...

Страница 13: ...ully open 4 Thermocouple connection loose at con trol valve 5 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one...

Страница 14: ...e 1 When heated vapors from furniture pol ish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance page 12 or replace burner orifice 2 Repl...

Страница 15: ...Gas Connections page 10 1 Refer to Fresh Air for Combustion and Ventilation requirements page 4 OBSERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater pr...

Страница 16: ...16 105717 VENT FREE NATURAL GAS HEATER MBN10LA AND MBN6LA 12 2 12 1 ILLUSTRATED PARTS LIST MBN10LA MBN6LA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 17 18 21 22 25 20 24 23 19 26 27 16...

Страница 17: ...01 098249 01 Nut M5 2 12 099440 03 100701 03 ODS Pilot Assembly 1 12 1 098514 01 098514 01 Thermocouple 1 12 2 098594 01 098594 01 Ignitor Electrode 1 13 104263 01 104263 01 Burner 1 14 099387 05 099...

Страница 18: ...e part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they cannot supply original replacement part s contact Cans Unlimited Incorpo rated Parts Department at 1 8...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents la...

Отзывы: