Medallion MBN10LA Скачать руководство пользователя страница 11

11

105717

OWNER’S MANUAL

TO TURN OFF GAS

TO APPLIANCE

1.

Remove front panel (see Figure 10,
page 8).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

4.

Keep control knob pressed in for 30
seconds after pilot is lit. After 30 sec-
onds, release control knob. Follow
step 8 under Lighting Instructions
.

5.

Replace front panel.

OPERATING
HEATER

Continued

Thermocouple

Pilot Burner

Ignitor Electrode

Figure 16 - Pilot

 CAUTION: Do not try to ad-

just heating levels by using the
equipment shutoff valve.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
on page 10, column 3.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise 
to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Fol-
low “B” in the safety information on
page 10, column 3. If you don’t smell
gas, go to the next step.

5.

Press in control knob and turn coun-
terclockwise 

 to the PILOT

position. Keep control knob pressed
in for five (5) seconds (see Figure 15).

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The pilot can
be seen through the glass panel. If
needed, keep pressing ignitor button
until pilot lights.

Note:

 If pilot does not stay lit, refer

to Troubleshooting, pages 13 through
15. Also contact a qualified service
person or gas supplier for repairs. Un-
til repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure
.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7.

OFF

HIGH

PILOT

LOW

IGNITOR

Ignitor Button

Control Knob

Figure 15 - Control Knob In The OFF
Position

Shutting Off Heater

1.

Turn control knob clockwise 
to the PILOT position.

2.

Press in control knob and turn clock-
wise 

 to the OFF position.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise 

 to

the PILOT position.

MANUAL LIGHTING

PROCEDURE

8.

Turn control knob counterclockwise

 to the HIGH position. The

main burner should light. Set control
knob to any heat level between HIGH
and LOW. To turn control knob from
HIGH to a lower setting, press in the
control knob and turn counterclock-
wise 

 .

Note:

 Both HIGH and LOW are

locked positions. You must press in
control knob before turning it from
these positions.

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 17 shows a correct pilot flame pat-
tern. Figure 18 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.

If pilot flame pattern is incorrect, as shown
in Figure 18

• turn heater off (see To Turn Off Gas to

Appliance, page 11)

• see Troubleshooting, pages 13 through 15

INSPECTING
BURNER

Figure 17 - Correct Pilot Flame Pattern

Figure 18 - Incorrect Pilot Flame Pattern

GRH/OV 009

GOOD PILOT

Thermocouple

Pilot Burner

GRH/OV 010

BAD PILOT

Pilot Burner

Thermocouple

Continued

Содержание MBN10LA

Страница 1: ...service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damage Re fer to this manual for correct installation and ope...

Страница 2: ...o run properly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Fresh Air for Combus tion and Ventilation...

Страница 3: ...or Button 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bou...

Страница 4: ...rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to...

Страница 5: ...l fuel burning appliances in the space Vent free heater _____________ Btu Hr Gas water heater _____________ Btu Hr Gas furnace _____________ Btu Hr Vented gas heater _____________ Btu Hr Gas fireplace...

Страница 6: ...ls or ducts Figure 2 Ventilation Air from Inside Building WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appl...

Страница 7: ...rents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oi...

Страница 8: ...lls 1 4 to 1 2 thick Figure 7 Popping Open Anchor Wings For Thin Walls Figure 6 Folding Anchor Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place...

Страница 9: ...ible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance Installsedimenttrapinsupplylineasshown in Figure 12 Locate sediment trap where it is within reach...

Страница 10: ...heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct...

Страница 11: ...tton until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 13 through 15 Also contact a qualified service personorgassupplierforrepairs Un til repairs are made light pilot...

Страница 12: ...circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleaning due to excessiv...

Страница 13: ...ully open 4 Thermocouple connection loose at con trol valve 5 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one...

Страница 14: ...e 1 When heated vapors from furniture pol ish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance page 12 or replace burner orifice 2 Repl...

Страница 15: ...Gas Connections page 10 1 Refer to Fresh Air for Combustion and Ventilation requirements page 4 OBSERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater pr...

Страница 16: ...16 105717 VENT FREE NATURAL GAS HEATER MBN10LA AND MBN6LA 12 2 12 1 ILLUSTRATED PARTS LIST MBN10LA MBN6LA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 17 18 21 22 25 20 24 23 19 26 27 16...

Страница 17: ...01 098249 01 Nut M5 2 12 099440 03 100701 03 ODS Pilot Assembly 1 12 1 098514 01 098514 01 Thermocouple 1 12 2 098594 01 098594 01 Ignitor Electrode 1 13 104263 01 104263 01 Burner 1 14 099387 05 099...

Страница 18: ...e part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they cannot supply original replacement part s contact Cans Unlimited Incorpo rated Parts Department at 1 8...

Страница 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 20: ...furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents la...

Отзывы: