background image

      

ActiveCare - Standard 

              User Manual 

 

MAN-ActiveCare REV03 

ActiveCare Standard USER MANUAL 

Page 1 of 33 

 

 

 

 

 
 
 
 
 

 

 
 
 

 

ActiveCare-Standard 

 

USER MANUAL 

For Parts or Technical Assistance - (877) 867-7365 

Содержание ActiveCare-Standard

Страница 1: ...ActiveCare Standard User Manual MAN ActiveCare REV03 ActiveCare Standard USER MANUAL Page 1 of 33 ActiveCare Standard USER MANUAL For Parts or Technical Assistance 877 867 7365 ...

Страница 2: ...pecifications 6 Intended Users 7 Bed Placement Dimension 7 Options and Accessories 8 Preparation for Use Unpacking 9 Assembly 13 Pivot Alignment 18 Mattress Installation 20 Pivot Turn Opposite Direction 22 Switching Hand Pendant to Opposite Side 24 Operation Control Options 29 Bed Transport 30 Maintenance Cleaning 30 Maintenance and Service 30 Service Part List 31 Warranty 33 ...

Страница 3: ...ant mattress bedding and any other items on the bed deck The bed is intended for operation by adult users who have read and understand this User Manual The bed is intended for indoor use in environments where it will not get wet where floors are stable and level and in ambient temperatures between 41 F and 104 F The bed is intended for operation on 120 VAC 60 Hz mains power The bed is not intended...

Страница 4: ...t is not working properly Contact Qualified Service Personnel for inspection and or repair Failure to do so could result in personal injury WARNING DO NOT sit or lie on hand control It can cause unintended movement of the application WARNING Ensure the main power cord is routed where it is not pinched either under or beside the bed Failure to do so could result in personal injury or equipment dama...

Страница 5: ...drive bed mechanisms can cause serious injury if operated improperly Operate the bed only when persons are clear of the mechanisms CAUTION When lowering the bed or knee in chair position always ensure limbs or extremities are not under any portion of the bed or mattress CAUTION Always confirm limbs or extremities are within the perimeter of the mattress and not in a position where they can be trap...

Страница 6: ... CAUTION Clean the hand control regularly to ensure good hygiene standards Maintenance and Service Safety WARNING Before performing bed maintenance or service unplug the power cord to avoid an electric shock hazard WARNING If a fault or problem is found during preventative maintenance inspections remove the bed from service until the appropriate repair or adjustment is made Specifications Low Deck...

Страница 7: ...ActiveCare Standard User Manual MAN ActiveCare REV03 ActiveCare Standard USER MANUAL Page 7 of 33 Intended Users Bed Placement Dimensions ...

Страница 8: ...ge 8 of 33 Options and Accessories UD Rails 1 4 rails for head Pivoting Assist Bars not available on same side of bed as Mobility Bar Mobility Bar Trapeze Battery Backup Trend Reverse Trend Handset End Boards Headboard and Footboard Finish Options Custom Headboard and Footboards Available ...

Страница 9: ...packing If Shipped LTL Commercial Tools Required Utility knife side cutting shears Socket with rachet impact driver 9 16 Wrench 1 Carefully remove outside box and shrink wrap with utility knife Do not puncture boxes or mattress 2 Cut the three straps holding the boxes and Bed unwrapped Cut the straps ...

Страница 10: ... Standard User Manual MAN ActiveCare REV03 ActiveCare Standard USER MANUAL Page 10 of 33 3 Remove boxes and mattress and put them off to the side 4 Unbolt the four anchor bolts on each end of the bed Anchor bolts ...

Страница 11: ...rd User Manual MAN ActiveCare REV03 ActiveCare Standard USER MANUAL Page 11 of 33 5 Lift bed off pallet and put on installation blocks installation blocks included with bed in small box Frame resting on assembly blocks ...

Страница 12: ...ual MAN ActiveCare REV03 ActiveCare Standard USER MANUAL Page 12 of 33 6 Remove cable ties from frame 7 Remove white shipping bracket from frame use 9 16 wrench 8 Remove Pendant from box Cable tie locations White shipping bracket ...

Страница 13: ...eCare Standard USER MANUAL Page 13 of 33 Assembly Tools Required 5 8 Wrench 5 8 Socket 6 Socket Extension Ratchet Impact Driver Side Cutters 1 Begin with bed frame resting on installation block as seen in unpacking instructions Frame resting on assembly blocks ...

Страница 14: ...ermined which high low assembly goes to the head and foot of the bed The foot weldment has the Med Mizer logo welded on the bottom and the head weldment has wall bumpers at the bottom of the weldment Foot Weldment with Med Mizer strap Head Weldment with rubber wall bumpers Head End of Bed Foot End of Bed ...

Страница 15: ... weldments to the frame using the bolts and nuts provided The high low assembly bosses must go on top of the frame bosses 4 Hand tighten nuts to each bolt and fasten firmly using the 5 8 ratchet impact and 5 8 wrench High Low weldment mounted on top of frame boss Hand tighten nut Firmly fasten nuts and bolts together ...

Страница 16: ...e Standard USER MANUAL Page 16 of 33 5 Install motor extension cable into actuator Ensure cable is full inserted then install c clip 6 Zip tie cable to the two attachment points and cut excess Two zip ties C Clip Cable should look like this once clip is installed ...

Страница 17: ...3 ActiveCare Standard USER MANUAL Page 17 of 33 7 Install head foot board to the weldment Slide board mount brackets down into channel brackets Board mounting brackets Channel Brackets Installed Board To secure in place push down on board until it stops ...

Страница 18: ...MANUAL Page 18 of 33 8 Repeat steps 3 through 7 to install opposite end high low weldment Pivot Alignment If Needed Tools Required 2 wrenches 1 Go behind the headboard of the bed and find the adjustment bracket and the two bolts Adjustment bracket Bolts holding adjustment bracket ...

Страница 19: ...Using the two wrench loosen each bolt turn do not fully disassemble Once loose straighten the bed out View images below to see incorrect alignment and correct alignment The pivoting and fixed sections of the bed should be parallel Once straight retighten the bolts Incorrect Alignment Correct Alignment ...

Страница 20: ...ActiveCare REV03 ActiveCare Standard USER MANUAL Page 20 of 33 Mattress Installation 1 Using the auto contour button raise the head and leg section of the bed 2 Locate the straps on the back of the mattress Straps Strap attachment points ...

Страница 21: ...re REV03 ActiveCare Standard USER MANUAL Page 21 of 33 3 Place mattress on bed and Velcro the straps to the sleep surface 4 Install foot portion of the mattress with the slope going towards the foot board Straps Slope going towards the footboard ...

Страница 22: ...pact 1 In the bed position raise the height of the bed and head of the bed to its highest point 2 Locate and remove the two bolts pictured below that hold the actuator into place Once removed install the actuator to the corresponding holes on the opposite side of the bed Bed and head section raised all the way up Remove bolts using 17mm wrench and socket Corresponding locations to install actuator...

Страница 23: ...n actuator mounts Tighten the fastener so that the bolt comes through the nylon nut but do not overtighten or the actuator will bind causing damage Actuator should pivot freely Image from underneath the bed Actuator Corresponding locations to install actuator Actuator mounted in Left turn Position Reinstall spacers as seen in the picture ...

Страница 24: ...33 Swapping Hand Pendant factory installed to the Left side of bed Beds without Trendelenburg handset Tools Required 5 16 Socket Impact driver ratchet 1 Raise head of the bed all the way up and locate pendant 2 Locate the two attachment points for on the back of the head section Attachment points ...

Страница 25: ...e Standard USER MANUAL Page 25 of 33 3 Unscrew the pendant clip and move to the opposite side of the head section Note Ensure pendant cord is not wrapped around the head actuator Pendant moved to opposite side Make sure pendant cord is not wrapped around actuator ...

Страница 26: ... 33 Bed with Trend Handset 1 Remove wire clamp from bottom of head sleep surface using a 5 16 socket And unplug pendant 2 Using two 1 2 inch wrenches remove the nut from pivot bolt for the head sleep surface Remove the pendant cable mounting plate from the bolt and replace the nut and re tighten ...

Страница 27: ... to release excess cord 4 On the left side of the bed remove the pivot nut using two 1 2 inch wrenches as done on the right side Route the pendant cord to the left side of the bed in the same fashion as pictured and hang the mounting bracket on the bolt Re tighten the nut while keeping the mounting bracket hanging straight down ...

Страница 28: ...stening it in the same location as the excess cable was tied originally Be sure the cable slack is removed where it is routed across the bed to prevent the cable from being pinched during normal bed operation 6 Plug pendant back into the cord Using a 5 16 socket remove the self tapping screw located under the head sleep surface rail on the left side of the bed ...

Страница 29: ...ight Down Auto Contour Up Auto Contour Down Knee Up Knee Down Rotate Bed into Chair Position Return Bed to Normal Bed Position Under Bed Lights Switch Transport Mode NOTE Hold button to rotate entirely once rotated entirely release button Then press and hold button again to lower the legs to a complete chair position Only available on the Deluxe Bed Only available on the Deluxe Bed ...

Страница 30: ...NANCE EVERY 12 MONTHS FOR BEST PERFORMANCE 1 Inspect the frame for weld cracks or tears 2 Check that all bolts pins and fasteners are still in working order 3 Perform functional test on the frame 4 Inspect the casters for wear and tear Preventative Maintenance Inspections Problem Resolution Inspect bed frame for cracks tears or bending particularly at welds and joints Remove bed from service Conta...

Страница 31: ... control switches operate correctly Contact Med Mizer customer service Service Parts List Contact Med Mizer customer service at 877 867 7365 to order parts PART DESCRIPTION 6201 LINAK POWER CHORD 11 FOOT W GROUND CABLE 912143 6947 HI LO BARIATRIC ACTUATOR 400504000A0M0G26 12DB16134200 6948 HI LOW HEAD 400402500A0M0G26 31DB142322000 6949 KNEE ACTUATOR 400400550A0M0B26 11DB129342000 6950 PIVOT ACTUA...

Страница 32: ...ol is defective Replace hand control Defective Control Box Replace control box Bed makes beeping sound with no function Motors need to be re initialized See Motor Re Initialization in manual Control Box Reinitialization If needed To reinitialize the bed hold down the Head up and down control buttons for 10 seconds until the beeping stops first row of buttons on pendant This will reset the control ...

Страница 33: ...ressly limited to supplying replacement parts for or replacing at its option any product which is in the sole discretion of Med Mizer found to be defective This warranty does not cover failure due to negligence accident abuse or installation not in accordance with the company s instructions or failure to follow maintenance instructions If requested by Med Mizer products or parts for which a warran...

Отзывы: