electromechanical operator for sliding gates
Nyota 115 evo
15
Anchor bracket
Nameplate
Screws xing the motor to
the anchor bracket
Coded key for the
release handle
Nyota 115 evo
GENERAL DESCRIPTION OF THE PRODUCT
Nyota 115 evo is an electromechanical operator to open and close sliding gates of any design and size up to a maximum weight of
1.850 kg. Two distinct voltage versions are available, single- and three-phase, both include 0,5 HP and 1,0 HP motors.
The Nyota 115 evo operators have steel-bronze mechanical coupling ie. worm and crown gear in an oil bath ; all supported by radial
bearings and thrust ball bearings to ensure the utmost in product reliability. The entire body and the cover are made of painted
pressure cast aluminium. The operator comes either in the version with incorporated control board (Elpro 12 evo) or stand alone
control box (Elpro 37/37 DS). Some accessories are required to ensure full safety and control of the system and make this operator
suitable to any application, in both public and private installations.
COMPONENTS AND PARTS INCLUDED IN THE EQUIPMENT
Pic. 1
This symbol means that particular attention is to be paid to installation operations and rst running test.
Failing to respect such indications may affect the functioning of the Nyota 115 evo gate operator.
!
Position Description
Type of electric cable
Flasher
Photocell receiver
Nyota 115 evo whit programmer and radio plugin card
Photocell projector
Keyswitch
Post for photocell receiver
Ground stop in closed and open gate positions
Electric cable junction box
Post for photocell projector
Transmitter
2 x 0,5 (FROR CEI 20-20-EN 50267-2-1), RG58 for aerial
4 x 0,5 (FROR CEI 20-20-EN 50267-2-1)
supply voltage 3 x 1,5 (FROR CEI 20-20-EN 50267-2-1)
2 x 0,5 (FROR CEI 20-20-EN 50267-2-1)
4 x 0,5 (FROR CEI 20-20-EN 50267-2-1)
4 x 0,5 (FROR CEI 20-20-EN 50267-2-1)
2 x 0,5 (FROR CEI 20-20-EN 50267-2-1)
Indicative general layout: Nyota 115 evo with Elpro 12 evo. It is the installer’s care laying the piping for the electrical connections in the correct and proper way.
ELECTRICAL WIRING PREPARATIONS AND ACCESSORIES
Pic. 2
1
2
3
4
5
6
7
8
9
10
!
The system is to be 230 V - 50 Hz power supplied and the
mains has to go through a magneto-thermal, differential,
0,03 A circuit breaker (2,5 mm² cable beyond 100 m).
The entire installation must be properly grounded.
The entire installation must be properly grounded.
Magnetic limit switch brackets,
right- and left-handed
!
made in It aly
www.fadini.net
installatore:
Data:
Modello:
N° serie:
CANCELLO
AUTOMATICO
l’apricancello
!
!
!
6
1
2
3
5
4
7
7
8
9
10