"3072RT / 3772RT / 3772RT HD" Service & Parts Manual - ANSI Specifications
Page 3-16
Outrigger Tilt Sensor Calibration
The integral tilt sensor of the GP106 Outrigger Control Module must be calibrated to compensate
for variations due to installation and vehicle construction. This procedure must be done if the
control module is ever repositioned or replaced.
a. Drive machine to level ground.
b. Plug EZ-Cal into connector P1 on the control module.
Display reads HELP: PRESS ENTER.
c. Press right arrow to ACCESS LEVEL 3, Press Enter.
Display reads CODE 0000.
d. Press up and right arrows to enter code 1775, Press Enter.
Display reads ACCESS LEVEL 2.
e. Right arrow to MACHINE SETUP, Press Enter.
Display reads CHANGE DEFAULTS.
f. Right arrow to CALIBRATE LEVEL, Press Enter.
Display reads CALIBRATE LEVEL: YES:ENTER,NO:ESC.
g. Press Enter. Display reads TILT 0.0’,0.0’
h. Press ESC, ESC
i. Disconnect EZ-Cal from the outrigger control module.
Outrigger calibration is now complete.