5.7 Fan-lock Protection
Figure 5
-
3
◎
There is a built-in fan-lock protection circuit. The output of all modules will shut off when the DC fan stops operating (fan-lock, loose
connector, or broken wires). Please turn off the AC power and remove the conditions causing fan-lock. If there are no observable
causes for fan-lock, please remove the unit from your system and send back to our local distributor or MEAN WELL for repair.
5.8
Remote Control
◎
There are built-in remote ON/OFF controls for Front-End and individual output modules.
◎
Connection diagram and control logics are shown below.
◎
Figure 5-4 shows RC1 (CN32 PIN6) and GND-P (CN32 PIN3) connection diagram.
5.6 Over Temperature Protection (OTP) and T-Alarm
◎
The Front-End has built-in thermal detection circuit. Once the internal temperature exceeds a preset value, there will be a “HIGH”
◎
When the internal temperature is within a normal value, the T-Alarm signal will be a “LOW” signal (-0.1~0.5V).
◎
.
T-Alarm's maximum sourcing current is 10mA
◎
Figure 5-3 shows T-Alarm (CN32 PIN5) and GND-PC (CN32 PIN3 or 4) connection diagram.
signal (4.5~5.5V) sent out through T-ALARM for end system to respond. If the internal temperature continues to increase and exceeds
the “safe limit” value, then the output will shut down automatically. Please switch off the AC input, remove all possible causes, and
then leave the unit to cool down to a normal working temperature (approximately 10 minutes ~ 1 hour) before re-power on.
T-Alarm Signal Voltage
Internal Temperature (U702)
4.5~5.5V
4.5~5.5V
0~0.5V
Exceeds the limit of T-Alarm
Exceeds the "safe limit"
The internal temperature is normal
Output Status
OFF
ON
ON
NMP1K2
1
T-Alarm
( PIN5)
GND-P
( PIN3 or 4)
5
2
6
CN32
CN32
6
6
5
5
2
2
1
1
TB1
TB1
N
N
L
L
+5V
-AUX-P
+5V
-AUX-P
RC1
GND-P
T-Alarm
GND-P
CN32
NMP650
NMP1K2
NMP650
1
GND-P
(PIN3)
CN32
RC1
(PIN6)
5
2
6
5.8.1
ON / OFF
Global
Connection Status
Output Status
Open
(SW OFF)
Short
(SW ON)
OFF
ON
CN32
CN32
6
6
5
5
2
2
1
1
TB1
TB1
N
N
L
L
+5V
-AUX-P
GND-P
+5V
-AUX-P
GND-P
RC1
T-Alarm
SW
Figure 5
-
4
Figure 5
-
5
Connection Status
Output Module Status
Short (SW ON)
Open (SW OFF)
OFF
ON
5.8.2
Local ON/OFF
◎
The NMS-240 modules can be turned ON/OFF individually by using the “local ON/OFF” function.
◎
Figure 5-5 shows RC2 (CN81 PIN3) and GND (CN81 PIN1 or 2) connection diagram.
※
The CN32 connection accessory (included in packaging) must be connected when using the local ON/OFF function.
NMS-240
GND
( PIN1 or 2)
RC2
( PIN3)
GND
1
GND
2
RC2
VCC2
CS
DC_OK
PC
CN81
PV
+S
-S
9
10
SW
+V
-V
-
+
LOAD
CN81
4 6 810
9
7
5
3
2
1
VR60
LED