background image

 

5

 

 

GENERAL ADVICE

 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

 

Before putting your dehumidifier into operation for the first time, the instruction manual should 
be studied carefully. 

 

 

After receiving the unit, you should check your dehumidifier for any transport damage. In case 
of damage, you should inform the sender immediately. 

 

 

Store  the  dehumidifier  box  and  packaging  in  a  safe  place 

–  this  will  be  required  if  the 

dehumidifier requires a service in the future. In order to save space, you can simply cut through 
the adhesive tape using a knife and fold up the cardboard box. 

 

 

DEHUMIDIFIER PRINCIPLES

 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

This  dehumidifier  is  designed  to reduce  humidity  from  the  air  in  a  building  or  part  of  a  building.  The 
purpose  is  to  prevent  humidity  damage  and  to  dry  out  wet  materials  such  as  carpet,  floors,  walls, 
furniture, contents, timber and structural materials.  

This dehumidifier can prevent the formation of condensation, reduce air humidity and keep constant a 
desired relative humidity level.  The time necessary for the dehumidifier to dry a room and reach the 
desired  humidity  level  depends  on  the  environmental  conditions  prevailing  within  the  room.  For 
example, the number of air changes with outside air, any sources of moisture and the room temperature 
can all either speed up or slow down the dehumidification process.  

The dehumidifier functions according to the condensation principles with heat recovery. The fan takes 
the  humid  air  from  the  room,  in  and  across  a  filter,  and  then  through  an  evaporator.  Here  the  air  is 
cooled below dew point, so that the water vapour of the air forms a condensate on the coils, which flows 
into  the  internal  container  ready  to  be  poured  away.  The  cooled  and  dried  air  is  heated  again  by  a 
condenser.  By  recycling  the  room  air  through  the  dehumidifier  repeatedly,  the  moisture  content  and 
relative humidity of the air is reduced.  

 

SET UP AND TRANSPORTATION 

---------------------------------------------------------------------------------------------------------------------------------------

 

The following instructions must be considered: 

 

Before using the dehumidifier, leave it to stand upright for 24 hours. 

 

 

Plug the unit directly into a wall socket and it will automatically enter continuous mode. 

 

 

Ensure there is at least 30cm of space around the unit to enable adequate air flow. The air inlet 
and the air outlet must not be covered whilst the dehumidifier is in operation. 

 

 

Make sure the water tank is securely in place. The unit will not switch on unless the water tank 
is secure. 

 

 

If you need to move the dehumidifier, it must be switched off by the power button on the unit. 
The mains plug must be removed from the socket and the water tank should be emptied. 

 

 

For  transportation,  the  dehumidifier  should  be  secured  on  a  level  base  only  and  must  be 
prevented from rolling around. 

 

 

The  dehumidifier  must  always  be  transported  vertically 

–  if  the  dehumidifier  has  been  in  a 

horizontal position for any time over a few minutes, you must let it stand in the upright position 
for at least 8 hours before operating. This allows the oil to drain back into the compressor.

 

Содержание 50Lm-v2

Страница 1: ...50Lm v2 Instruction Manual Meaco 50Lm Dehumidifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for choosing Meaco we really apprecia...

Страница 2: ...azardous condition Run on Stable Surface Always operate the unit on a stable level surface for example the floor or a strong counter so that the dehumidifier cannot fall and cause injury Keep Out of W...

Страница 3: ...om must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by an operating electric heaters operating gas a...

Страница 4: ...minal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the...

Страница 5: ...ry The fan takes the humid air from the room in and across a filter and then through an evaporator Here the air is cooled below dew point so that the water vapour of the air forms a condensate on the...

Страница 6: ...RODUCT IDENTIFICATION Front of the dehumidifier Back of the dehumidifier Pushing handle Control panel Air inlet Lift handle Water tank cover Big wheel Air outlet Power cord hook Power cord Radiator gr...

Страница 7: ...INSTALLATION Before use 1 Remove the dehumidifier from the packaging and take down the hand screw 2 Rotate the pushing handle aim it at the hole site then tighten the hand screws 3 Installation comple...

Страница 8: ...s drainage 1 Open the front panel remove the water tank and empty its contents 2 Remove the plug and attach the drainage pipe to the connector Direct the pipe to its desired drainage outlet before tur...

Страница 9: ...buttons to set the number of hours in which you want the dehumidifier to turn off Once the count down has finished the fan and compressor will turn off Press the timer button for three seconds to see...

Страница 10: ...multaneously opens the solenoid value Hot gas is guided into the evaporator until the latter is completely free of ice Subsequently the dehumidifier will operate again in its normal mode when the temp...

Страница 11: ...um of every two weeks not doing so could invalidate the units warranty Please use the following steps Pull the louvre on the front panel to gain access to the filter Remove the filter from the dehumid...

Страница 12: ...h a relative humidity from 20 rh to 90 rh It is suitable for applications residential buildings offices museums archives garages and storage rooms Temperature Range 5 C 38 C Relative Humidity Range 20...

Страница 13: ...dehumidifier only works between 5 C and 38 C LO The room humidity is below 20 rh There humidity level is too low there is no moisture to collect HI The room humidity is very high and above 95 rh Set...

Страница 14: ...damage caused by actions that deviate from those as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not...

Страница 15: ...harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return...

Отзывы: