The  Meaco  50Lm-v2  Dehumidifier  uses  the  new  R290  refrigerant  gas  to 
comply  with  European  Environmental  Directives.  R290  is  kinder  to  the 
environment and is part of attempts to reduce global warming as it has a low 
greenhouse effect (GWP).

 

 

 

When using the Meaco 50Lm-v2 Dehumidifier you must take into account the following: 

 

This dehumidifier uses about 230 grams of R290 refrigerant which is flammable, therefore it is 
part of a sealed system and must only be serviced by a trained Meaco engineer.

 

 

Do not use or store this dehumidifier in a room smaller than 12m² to prevent a fire or explosion 
hazard if there is a leak of refrigerant and the gas comes into contact with an ignition source.

 

 

Do not use in a room with any continuous sources of ignition, for example open flames, gas 
fires or hobs, cigarettes or any other sources of ignition.

 

 

Do  not  sure  means  to  accelerate  the  defrosting  process  or  to  clean,  other  than  those 
recommended by a trained Meaco engineer. 

 

 

If the dehumidifier is installed, operated or stored in a non-ventilated area, then the room must 
be  designed  to  prevent  the  accumulation  of  refrigerant  leaks  resulting  in  a  risk  of  fire  or 
explosion due to ignition of the refrigerant caused by an operating electric heaters, operating 
gas appliances or other sources of ignition.

 

 

R290 refrigerant gas is odourless.

 

 

Do not puncture or burn either during the units working life or after.  At the end of life dispose 
of following local recycling regulations.

 

 

If there is any damage to the unit then do not use it and contact Meaco or your retailer.  

 

 

As with all dehumidifiers, always keep upright and leave the dehumidifier standing upright for 
24 hours before using it upon receipt.

 

 

Failure to comply with these instructions could result in fire, damage to property, serious 
injury or potentially death. 

 

Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued 
by  a  national  accredited  organisation  that  ensures  competence  in  handling  flammable  refrigerants 
according  to  a  specific  evaluation  recognised  by  national  associations  in  the  industry  and  compliant 
with the latest R290 guidance. 

Servicing  should  only  be  carried  out  by  a  Meaco  approved  engineer  using  original  Meaco  parts  to 
prevent damage to the unit and potential injury to the engineer. 

 

 

 

 

 

 

 

Содержание 50Lm-v2

Страница 1: ...50Lm v2 Instruction Manual Meaco 50Lm Dehumidifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for choosing Meaco we really apprecia...

Страница 2: ...azardous condition Run on Stable Surface Always operate the unit on a stable level surface for example the floor or a strong counter so that the dehumidifier cannot fall and cause injury Keep Out of W...

Страница 3: ...om must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by an operating electric heaters operating gas a...

Страница 4: ...minal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the...

Страница 5: ...ry The fan takes the humid air from the room in and across a filter and then through an evaporator Here the air is cooled below dew point so that the water vapour of the air forms a condensate on the...

Страница 6: ...RODUCT IDENTIFICATION Front of the dehumidifier Back of the dehumidifier Pushing handle Control panel Air inlet Lift handle Water tank cover Big wheel Air outlet Power cord hook Power cord Radiator gr...

Страница 7: ...INSTALLATION Before use 1 Remove the dehumidifier from the packaging and take down the hand screw 2 Rotate the pushing handle aim it at the hole site then tighten the hand screws 3 Installation comple...

Страница 8: ...s drainage 1 Open the front panel remove the water tank and empty its contents 2 Remove the plug and attach the drainage pipe to the connector Direct the pipe to its desired drainage outlet before tur...

Страница 9: ...buttons to set the number of hours in which you want the dehumidifier to turn off Once the count down has finished the fan and compressor will turn off Press the timer button for three seconds to see...

Страница 10: ...multaneously opens the solenoid value Hot gas is guided into the evaporator until the latter is completely free of ice Subsequently the dehumidifier will operate again in its normal mode when the temp...

Страница 11: ...um of every two weeks not doing so could invalidate the units warranty Please use the following steps Pull the louvre on the front panel to gain access to the filter Remove the filter from the dehumid...

Страница 12: ...h a relative humidity from 20 rh to 90 rh It is suitable for applications residential buildings offices museums archives garages and storage rooms Temperature Range 5 C 38 C Relative Humidity Range 20...

Страница 13: ...dehumidifier only works between 5 C and 38 C LO The room humidity is below 20 rh There humidity level is too low there is no moisture to collect HI The room humidity is very high and above 95 rh Set...

Страница 14: ...damage caused by actions that deviate from those as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not...

Страница 15: ...harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return...

Отзывы: