![MDV M0BA30-11CFN1-MQ0W Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/mdv/m0ba30-11cfn1-mq0w/m0ba30-11cfn1-mq0w_technical-manual_1757523053.webp)
Pr
oduct Featur
es
Page 53
priority.
• The operating time for sleep mode is 7 hours, after
which, the unit exits this mode and switches off.
• The timer setting is available in this mode.
1.12 Auto-Restart function
• The indoor unit has an auto-restart module that
allows the unit to restart automatically. The module
automatically stores the current settings (do not
include the swing setting) , when meets power failure,
air conditioner will restore those setting automatically
within 3 minutes after power returns.
• If the unit was in forced cooling mode, it will run in
this mode for 30 minutes and turn to auto mode with
temperature set to 24°C.
• If there is a power failure while the unit is running, the
compressor starts 3 minutes after the unit restarts. If
the unit was already off before the power failure, the
compressor starts 1 minute after the unit restarts.
1.13 Refrigerant Leakage Detection
With this new technology, the display area will show “EC”
when the outdoor unit detects refrigerant leakage. This
function is only available in cooling mode.
1.14 Louver Position Memory Function
When starting the unit again after shutting down, its
louver will restore to the angle originally set by the user,
but the precondition is that the angle must be within
the allowable range, if it exceeds, it will memorize the
maximum angle of the louver. During operation, if the
power fails or the end user shuts down the unit in the
turbo mode, the louver will restore to the default angle.
1.15 Self clean(Optional)
• If you press “Self Clean” when the unit is in cooling or
drying mode:
• For cooling models, the indoor unit will run in low
fan mode for a certain time, then ceases operation.
• For heat pump models, the indoor unit will run in
fan-only mode, then low heat, and finally in fan-
only mode.
• Self Clean keeps the indoor unit dry and prevents
mold growth.
1.16 Follow me(Optional)
• If you press “Follow Me” on the remote, the indoor
unit will beep. This indicates the follow me function is
active.
• Once active, the remote control will send a signal
every 3 minutes, with no beeps. The unit automatically
sets the temperature according to the measurements
from the remote control.
• The unit will only change modes if the information
from the remote control makes it necessary, not from
the unit’s temperature setting.
• If the unit does not receive a signal for 7 minutes or
you press “Follow Me,” the function turns off. The
unit regulates temperature based on its own sensor
and settings.
1.17 Silence (Optional)
Press “Silence” on the remote control to enable the
SILENCE function. While this function is active, the
compressor frequency is maintained at a lower level than
F3. The indoor unit will run at faint breeze, which reduces
noise to the lowest possible level.
Содержание M0BA30-11CFN1-MQ0W
Страница 1: ...TM_AB_R410A_INV_US_NA_2009 R410A INVERTER CONTROL TECHNICAL MANUAL...
Страница 14: ...Specifications Page 14 MSABB 11CRFN1 BT0W MSABB 11CRFN1 MT0W MSABD 17CRFN1 MQ0W...
Страница 15: ...Specifications Page 15 MSABE 22CRDN1 MS0W...
Страница 17: ...Specifications Page 17 MOBA30 12CFN1 BP0W MOX130 11CFN1 MT0W...
Страница 18: ...Specifications Page 18 MOX130 11CFN1 BT0W MOBA30 09CFN1 MQ0W M0BA30 11CFN1 MQ0W...
Страница 19: ...Specifications Page 19 MOBA30 17CFN1 MR0W MOCA30 22CFN1 MR0W...
Страница 43: ...Specifications Page 43 MSABB 12CRDN1 BP0W MSABB 11CRFN1 BT MSABA 09CRDN1 MP0W MSABB 12CRDN1 MP0W...
Страница 44: ...Specifications Page 44 MSABB 11CRFN1 MT0W MSABD 17CRFN1 MQ0W MSABE 22CRDN1 MS0W 7 2 Outdoor Unit...
Страница 46: ...Specifications Page 46 MOBA30 12CFN1 BP0W MOX130 11CFN1 BT0W MOBA30 09CFN1 MQ0W M0BA30 11CFN1 MQ0W...
Страница 47: ...Specifications Page 47 MOX130 11CFN1 MT0W MOBA30 17CFN1 MR0W MOCA30 22CFN1 MR0W...