background image

 

 

Technical Manual IP-Router SCN-IP100.01 

 

 

 

MDT technologies GmbH  •  

51766 Engelskirchen  •  Papiermühle 1

 

 

Tel.: +49-2263-

880  •  Fax: +49-2263-4588  • [email protected]  •  www.mdt.de 

14

 

 

5 Index

 

 

5.1 Register of illustrations 

 

Figure 1: Structure of the hardware device  

 

 

 

 

 

Page 3 

Figure 2: KNX IP Router as Line Coupler   

 

 

 

 

 

Page 4 

Figure 3: KNX IP Router as a backbone coupler   

 

 

 

 

Page 5 

Figure 4: KNX IP Router as a backbone and line coupler   

 

 

 

Page 5 

Figure 5: General settings 

 

 

 

 

 

 

 

Page 7 

Figure 6: IP configuration 1 

 

 

 

 

 

 

 

Page 8 

Figure 7: IP configuration 2 

 

 

 

 

 

 

 

Page 8 

Figure 8: Routing (KNX --> IP)   

 

 

 

 

 

 

Page 10 

Figure 9: Routing (IP --> KNX)    

 

 

 

 

 

 

Page 11 

Figure 10: Communication Manager 

 

 

 

 

 

 

Page 13 

 

5.2 List of tables 

 
Chart 1: Structure 

 

 

 

 

 

 

 

 

Page 3 

 

Содержание SCN-IP100.01

Страница 1: ...MDT technologies GmbH 51766 Engelskirchen Papierm hle 1 Tel 49 2263 880 Fax 49 2263 4588 knx mdt de www mdt de 1 2012 Technical Manual MDT IP Router SCN IP100 01...

Страница 2: ...3 1 1 Installation and connection 3 2 1 Coupler function 4 2 2 Bus access function KNXnet IP Tunneling 6 3 ETS Parameter 7 3 1 General 7 3 2 IP Configuration 8 3 3 Routing KNX IP 10 3 4 Routing IP KNX...

Страница 3: ...Power over Ethernet IEEE 802 3af 1 1 Installation and connection The KNX IP Router is designed for installation in a rack with a depth of 2 units It contains the following display and control elements...

Страница 4: ...mbH 51766 Engelskirchen Papierm hle 1 Tel 49 2263 880 Fax 49 2263 4588 knx mdt de www mdt de 4 2 1 Coupler function The IP Router can operate as a line and or backbone coupler In both cases the LAN IP...

Страница 5: ...SCN IP100 01 MDT technologies GmbH 51766 Engelskirchen Papierm hle 1 Tel 49 2263 880 Fax 49 2263 4588 knx mdt de www mdt de 5 Figure 3 KNX IP Router as a backbone coupler Figure 4 KNX IP Router as a...

Страница 6: ...coupler x y 0 there must be no KNX IP Router in the topology above it For example if a KNX IP Router has the physical address of 1 1 0 there must be no KNX IP Router with the ad dress 1 0 0 The KNX I...

Страница 7: ...ive e g Line TF It is used to search for and recognize a device Monitoring bus voltage failure If a KNX EIB failure is detected it is reported on the IP Return of the bus voltage is also reported Para...

Страница 8: ...ion 1 Figure 6 IP configuration 1 IP Routing Multicast Address This address is used for routing telegrams on IP The multicast IP address 224 0 23 12 was reserved KNXnet IP at the IANA Internet Assigne...

Страница 9: ...ess of the gateway here Note If the KNX IP Router will only be used in the local LAN the entry of 0 0 0 0 can remain unchanged Example of assigning IP addresses A PC is to be used to access the KNX IP...

Страница 10: ...are routed to IP Route All group telegrams of main groups 14 and 15 are routed to IP Group telegrams main groups 16 to 31 Block No group telegrams of these main groups are routed to IP Route An addit...

Страница 11: ...is generated for every received physically addressed telegram from KNX EIB Only if routed An acknowledge is only generated for received physically addressed group telegrams from KNX EIB if they are ro...

Страница 12: ...disabled or enabled in pairs Physically addressed telegrams Block No physically addressed telegrams are routed to KNX EIB Route All physically addressed telegrams are routed to KNX EIB Filter The phy...

Страница 13: ...llowing configuration is necessary Select the button Settings and the tab Communication in the main window of ETS4 All available connections are listed by Configured connections Select the desired con...

Страница 14: ...e device Page 3 Figure 2 KNX IP Router as Line Coupler Page 4 Figure 3 KNX IP Router as a backbone coupler Page 5 Figure 4 KNX IP Router as a backbone and line coupler Page 5 Figure 5 General settings...

Страница 15: ...can occur danger for humans animals or material assets Do not let the packaging lying around careless plastic foil bags etc can be a dangerous toy for kids 6 2 Routine disposal Do not throw the waste...

Страница 16: ...lectrical isolation between the lines and reduction of the busload by using the filter function The MDT KNX Interfaces are modular installation devices for fixed installation in dry rooms They fit on...

Страница 17: ...ore 0 8mm solid core 0 8mm solid core Power Supply via KNX bus 12 to 24VAC DC 12 to 24VAC DC via KNX bus Power consumption 0 3W 0 8W 0 8W 0 3W each line Operation temperature range 0 to 45 C 0 to 45 C...

Отзывы: