The tree menu architecture is explained below. Items highlighted in blue are state menu ( - ), and 
those highlighted in yellow are control menu ( 

 ). 

 

 

STATUS 

 

Status menu   

 

     

STATE 

---- 

Status 

State

 

 

 

 

 

UNIT OFF  

- the generator is 

off

  

 

 

 

 

xx% HEAT  

- the generator is 

heating

, but not ready 

 

 

 

 

PURGE 

- the generator is 

purging

 the heating module 

 

 

 

 

READY 

- the generator is generator is 

ready

 to produce fog 

 

 

 

 

FOG ON 

- the generator is producing

 Fog

 

 

 

 

 

FAIL 

- the generator is off, due to a 

failure

 (see diagnostic) 

       ERROR 

---- 

Error

 message when 

State = FAIL

 (see diagnostic)

 

 

 

TEMP. 

---- 

Temperature

 status (heating module) 

 

 

 

 

TOO LOW 

- temperature 

too low

  

 

 

 

 

OK 

- temperature within specifications (

ready

 

 

 

 

TOO HIGH 

- temperature 

too high

 

     

PRESSURE 

xx.x 

Current reservoir 

pressure

 

 

 

PCB TEMP 

---- 

Temperature

 of the board (see Units) 

     

RUN TIME 

xx.x 

Total Run Time in decimal hours

 

     

FOG TIME 

xx.x 

Total Fog Time in decimal hours 

     

LAST ERR 

yyyyy 

Code for the Last five (5) errors 

 

 

 

 

 

See 

Fail State

 paragraph

 

 

 

 

CONTROL

 

 

Control menu

   

     

UNIT 

---- 

Unit

 toggle 

 

 

 

 

OFF  

- the generator is 

off

  

 

 

 

 

ON  

- the generator is 

on

  

     

FOG 

----  

Fog

 toggle

 

 

 

 

 

OFF  

- the fog is 

off

  

 

 

 

 

ON  

- the fog is 

on

  

      

SET PRES. 

xx.x 

Fog

 operating 

pressure

 (see Units)

 

 

 

Содержание ME2

Страница 1: ...A D E IN CAN A D A F A B R IQU AU CA N A D A 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com Operating Guide...

Страница 2: ...Me2 Fog Generator Operating Guide Rev A a 2 30 Intentionally left blank...

Страница 3: ...ight Notice 5 Basic description 6 Installing the Me2 8 Working with the Me2 9 The Keyboard 10 LCD Saver 10 Menu Tree 11 Operating instructions 14 DMX Control 17 Bootloader 18 RDM Control 18 Fog fluid...

Страница 4: ...nufacturer its service agent or similarly qualified persons in order to avoid a hazard HOW TO READ THIS OPERATING GUIDE WARNING and CAUTION are used throughout this manual to forewarn of possible dang...

Страница 5: ...installation We re looking forward to go that extra mile for you Contact us By Phone 1 800 663 3020 1 514 272 6040 By Fax 1 514 722 3229 By e mail info mdgfog com On the Web www mdgfog com The QR code...

Страница 6: ...g until the temperature of the heating module is back within parameters A fourth safety system consists of a pressure relief valve which limits the working pressure and protects against over pressure...

Страница 7: ...erator Operating Guide Rev A a 7 30 MAIN POWER Switch VAC Input 100 250 VAC 50 60 Hz Handle Fog output nozzles XLR 5 DMX RDM Connector LCD Keyboard Fog fluid reservoir CO2 or N2 Gas input 50 60 psi US...

Страница 8: ...quires 2 m 6 56 ft of clearance to the front Fill the reservoir with MDG Neutral Fog Fluid see Filling the Fluid Reservoir paragraph Connect the gas inlet to a gas bottle equipped with a single or dou...

Страница 9: ...Load These four seconds allow you to connect the generator to your PC via a USB cable to update the firmware of the control board see BootLoader for further details Then the MDG Me2 will display durin...

Страница 10: ...e reaches its maximum value the program continues with the minimum value Mode moves the last selection to the upper level This key has no effect in the first level In a data input menu pressing this k...

Страница 11: ...to define or verify the communication via DMX RDM Settings Menu summarizes general configuration of the generator The menu is refreshed every second Items preceded by the character are state messages...

Страница 12: ...is off due to a failure see diagnostic ERROR Error message when State FAIL see diagnostic TEMP Temperature status heating module TOO LOW temperature too low OK temperature within specifications ready...

Страница 13: ...R yyy DMX Address 1 to 510 Network DMX RDM 1 UNIT yyy Channel 1 value OFF 50 128 ON 2 OUTPUT yyy Channel 2 value 0 0 to 100 255 3 FOG yyy Channel 3 value OFF 50 128 ON SETTINGS Settings menu UNITS Uni...

Страница 14: ...omatic Purging System APS will be initiated STATUS STATE PURGING After the first purging cycle is completed approx time 30 sec the generator is ready to produce fog Fog Production When the generator i...

Страница 15: ...mperature of the heating module is not increasing with the proper thermal ramp This is generally due to a heater cartridge s problem Shut down the generator and restart it Check the heating process wi...

Страница 16: ...or a sensor problem Shut down the generator and restart it ERROR PCB HIGH LAST ERR CODE D This error will occur when the internal temperature of the generator is too high This may happen if the extern...

Страница 17: ...signal is lost the generator keeps the last DMX values WARNING In AUTO Mode DMX commands always take precedence over Local commands The MDG Me2 provides a simple way to check if there is DMX signal T...

Страница 18: ...B Male Male type Contact the MDG Service to have the last package firmware upgrade for the MDG Me2 RDM CONTROL The MDG Me2 can be controlled via a RDM ANSI E1 20 protocol an intelligent bi directional...

Страница 19: ...FO 0x0060 PRODUCT_DETAIL_ID_LIST 0x0070 DEVICE_MODEL_DESCRIPTION 0x0080 White Mineral oil hazer MANUFACTURER_LABEL 0x0081 MDG Fog Generators Ltd DEVICE_LABEL 0x0082 SOFTWARE_VERSION_LABEL 0x00C0 DMX_P...

Страница 20: ...G distributors or dealers Available in 4 L 1 US gallon 5 L Europe Only 20 L 5 3 US gallon 205 L 55 US gallon and 1000 L 264 US gallon FILLING THE FLUID RESERVOIR WARNING Use only MDG Neutral Fog Fluid...

Страница 21: ...1415 W Verify the AC voltage on the power cord 100 250 VAC The generator does not produce fog Verify that the Unit is ON CONTROL UNIT ON Verify that the UNIT is READY STATUS STATE READY The generator...

Страница 22: ...alfunction Restart the generator Please contact MDG Service if this problem persists ERROR HEATER This is a heating timeout due to a cartridge heater problem Restart the generator and check the heatin...

Страница 23: ...SET Restart the generator Please contact MDG Service if this problem persists LCD displays strange letters or does not seem to work normally In some conditions Radio transmission or static discharges...

Страница 24: ...easier on your generator with special compartments for accessories like cable extensions and remote control timers PORTABILITY OPTION The portability option stores the gas canister securely underneath...

Страница 25: ...kg 5 9 lb per hour at 2 76 bar 40 psi Automatic Purging System Standard feature Warm up time 8 minutes Operating voltage 100 250 VAC 50 60Hz 1 phase Ground Earth connection REQUIRED Power consumption...

Страница 26: ...Me2 Fog Generator Operating Guide Rev A a 26 30 Dimensions...

Страница 27: ...Me2 Fog Generator Operating Guide Rev A a 27 30...

Страница 28: ...his warranty MDG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines respo...

Страница 29: ...Me2 Fog Generator Operating Guide Rev A a 29 30 Declaration of conformity...

Страница 30: ...Me2 Fog Generator Operating Guide Rev A a 30 30 Notes...

Отзывы: