background image

 

 

Me2, Fog Generator

 

 

Operating Guide, Rev: A/a 

10 / 30

 

T

HE 

K

EYBOARD

 

The user can scroll in the menu by using the buttons of the keyboard: 
 

Down

’ moves the selection to the next menu, or decrease a data value. 

 

When at the end of a list, the program moves back to the first item of this list. 

 

If the selected menu is a 

data input menu

, keeping this key pressed will decrease 

the value more rapidly. 

 

In  a 

data input menu

,  when the value  reaches its minimum value, the program 

continues with the maximum value. 

 

Up

’ moves the selection to the previous menu, or increase a data value. 

 

If the item is the first of a menu, the program moves the selection to the last item 
of that menu. 

 

If the selected menu is a 

data input menu

, keeping this key pressed will increase 

the value more rapidly. 

 

In a 

data input menu

, when the value reaches its maximum value, the program 

continues with the minimum value. 

 

 ‘

Mode

’ moves the last selection to the upper level   

 

This key has no effect in the first level. 

 

In a 

data input menu

, pressing this key allows to exit the menu without changing 

any value (escape). 

 

 ‘

Enter

’ confirms a selection or data value. 

 

This key has the same effect that the key ‘

’, when scrolling through the menus. 

 

In  a 

toggle menu

,  this key confirms the selection and moves the cursor back to 

the upper level menu. 

 

In  a 

data  input  menu

,  this  key  confirms  the  value  of  the  data  and  moves  the 

cursor back to the upper level menu.  

 

LCD

 

S

AVER

 

The program can automatically switch off the LCD screen (menu display and backlight) if there is 
no  keyboard  activity.  The  user  can  choose  between  a  30  second  and  a  2  minute  delay  in  the 

Settings Menu

 (« SETTINGS

LCD SAVER »).  

When the LCD Saver is activated, just press any key of the keyboard to re-activate the LCD screen 
functions.   
The user can also deactivate the LCD saver by selecting the OFF option.   

Содержание ME2

Страница 1: ...A D E IN CAN A D A F A B R IQU AU CA N A D A 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com Operating Guide...

Страница 2: ...Me2 Fog Generator Operating Guide Rev A a 2 30 Intentionally left blank...

Страница 3: ...ight Notice 5 Basic description 6 Installing the Me2 8 Working with the Me2 9 The Keyboard 10 LCD Saver 10 Menu Tree 11 Operating instructions 14 DMX Control 17 Bootloader 18 RDM Control 18 Fog fluid...

Страница 4: ...nufacturer its service agent or similarly qualified persons in order to avoid a hazard HOW TO READ THIS OPERATING GUIDE WARNING and CAUTION are used throughout this manual to forewarn of possible dang...

Страница 5: ...installation We re looking forward to go that extra mile for you Contact us By Phone 1 800 663 3020 1 514 272 6040 By Fax 1 514 722 3229 By e mail info mdgfog com On the Web www mdgfog com The QR code...

Страница 6: ...g until the temperature of the heating module is back within parameters A fourth safety system consists of a pressure relief valve which limits the working pressure and protects against over pressure...

Страница 7: ...erator Operating Guide Rev A a 7 30 MAIN POWER Switch VAC Input 100 250 VAC 50 60 Hz Handle Fog output nozzles XLR 5 DMX RDM Connector LCD Keyboard Fog fluid reservoir CO2 or N2 Gas input 50 60 psi US...

Страница 8: ...quires 2 m 6 56 ft of clearance to the front Fill the reservoir with MDG Neutral Fog Fluid see Filling the Fluid Reservoir paragraph Connect the gas inlet to a gas bottle equipped with a single or dou...

Страница 9: ...Load These four seconds allow you to connect the generator to your PC via a USB cable to update the firmware of the control board see BootLoader for further details Then the MDG Me2 will display durin...

Страница 10: ...e reaches its maximum value the program continues with the minimum value Mode moves the last selection to the upper level This key has no effect in the first level In a data input menu pressing this k...

Страница 11: ...to define or verify the communication via DMX RDM Settings Menu summarizes general configuration of the generator The menu is refreshed every second Items preceded by the character are state messages...

Страница 12: ...is off due to a failure see diagnostic ERROR Error message when State FAIL see diagnostic TEMP Temperature status heating module TOO LOW temperature too low OK temperature within specifications ready...

Страница 13: ...R yyy DMX Address 1 to 510 Network DMX RDM 1 UNIT yyy Channel 1 value OFF 50 128 ON 2 OUTPUT yyy Channel 2 value 0 0 to 100 255 3 FOG yyy Channel 3 value OFF 50 128 ON SETTINGS Settings menu UNITS Uni...

Страница 14: ...omatic Purging System APS will be initiated STATUS STATE PURGING After the first purging cycle is completed approx time 30 sec the generator is ready to produce fog Fog Production When the generator i...

Страница 15: ...mperature of the heating module is not increasing with the proper thermal ramp This is generally due to a heater cartridge s problem Shut down the generator and restart it Check the heating process wi...

Страница 16: ...or a sensor problem Shut down the generator and restart it ERROR PCB HIGH LAST ERR CODE D This error will occur when the internal temperature of the generator is too high This may happen if the extern...

Страница 17: ...signal is lost the generator keeps the last DMX values WARNING In AUTO Mode DMX commands always take precedence over Local commands The MDG Me2 provides a simple way to check if there is DMX signal T...

Страница 18: ...B Male Male type Contact the MDG Service to have the last package firmware upgrade for the MDG Me2 RDM CONTROL The MDG Me2 can be controlled via a RDM ANSI E1 20 protocol an intelligent bi directional...

Страница 19: ...FO 0x0060 PRODUCT_DETAIL_ID_LIST 0x0070 DEVICE_MODEL_DESCRIPTION 0x0080 White Mineral oil hazer MANUFACTURER_LABEL 0x0081 MDG Fog Generators Ltd DEVICE_LABEL 0x0082 SOFTWARE_VERSION_LABEL 0x00C0 DMX_P...

Страница 20: ...G distributors or dealers Available in 4 L 1 US gallon 5 L Europe Only 20 L 5 3 US gallon 205 L 55 US gallon and 1000 L 264 US gallon FILLING THE FLUID RESERVOIR WARNING Use only MDG Neutral Fog Fluid...

Страница 21: ...1415 W Verify the AC voltage on the power cord 100 250 VAC The generator does not produce fog Verify that the Unit is ON CONTROL UNIT ON Verify that the UNIT is READY STATUS STATE READY The generator...

Страница 22: ...alfunction Restart the generator Please contact MDG Service if this problem persists ERROR HEATER This is a heating timeout due to a cartridge heater problem Restart the generator and check the heatin...

Страница 23: ...SET Restart the generator Please contact MDG Service if this problem persists LCD displays strange letters or does not seem to work normally In some conditions Radio transmission or static discharges...

Страница 24: ...easier on your generator with special compartments for accessories like cable extensions and remote control timers PORTABILITY OPTION The portability option stores the gas canister securely underneath...

Страница 25: ...kg 5 9 lb per hour at 2 76 bar 40 psi Automatic Purging System Standard feature Warm up time 8 minutes Operating voltage 100 250 VAC 50 60Hz 1 phase Ground Earth connection REQUIRED Power consumption...

Страница 26: ...Me2 Fog Generator Operating Guide Rev A a 26 30 Dimensions...

Страница 27: ...Me2 Fog Generator Operating Guide Rev A a 27 30...

Страница 28: ...his warranty MDG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines respo...

Страница 29: ...Me2 Fog Generator Operating Guide Rev A a 29 30 Declaration of conformity...

Страница 30: ...Me2 Fog Generator Operating Guide Rev A a 30 30 Notes...

Отзывы: