Me2, Fog Generator
Operating Guide, Rev: A/a
16 / 30
ERROR = T. HIGH
LAST ERR CODE = 4
This error will occur if the temperature of the heating module is too high.
This is generally due to an electronic problem. Shut down the generator and restart it.
ERROR = T. SAF
LAST ERR CODE = 5
This error will occur if abnormal temperature difference between the two sensors of the
heating module is detected.
This is generally due to an electronic or a sensor problem. Shut down the generator and
restart it.
ERROR = PCB HIGH
LAST ERR CODE = D
This error will occur when the internal temperature of the generator is too high.
This may happen if the external temperature is high. Move the generator in the shade or to a
cooler location. Shut down, wait few minutes, and then restart the generator.
ERROR = WD RST
LAST ERR CODE = E
This error will occur if the watchdog (software safety) resets the generator.
This is generally due to software error, an interference or chip problem. Shut down the
generator and restart it.
Please contact an Authorized Service Center if any problem persists.