background image

 

 

D-Verter

 

 

User Guide, Rev: A/b 

6 / 23

 

B

ASIC 

D

ESCRIPTION

 

The  MDG 

D-Verter™

  is  a  DMX  pneumatic  device  which  mechanically  either,  splits  a  single 

source of fog into two distinct outputs, merges two separate sources of fog into a single output, 
or acts as a fog output gate.  
Low  power  consumption  (only  50  W),  controllable  via  DMX  or  RDM,  this  mechanical  Fog 
Input/Output Splitter can be used anywhere due to its universal switching power supply (100-250 
VAC, 50/60 Hz). 
Its simple and efficient multi-level User Interface,  accessible  from  the backlit  LCD panel, allows 
for a gradual switch between local mode and most common protocols: DMX-512-A USITT and 
RDM ANSI E1.20.  
 

 

WARNING

  

 

When  not  in  use 

ALWAYS

  switch  off  the  power  switch  located  on  the  front 

panel, or 

unplug

 the appliance. 

 

Never install above people. 

 

 

 

 

 

Содержание D-Verter

Страница 1: ...td M A D E IN CAN A D A F A B R IQU AU CA N A D A 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com User Guide...

Страница 2: ...D Verter User Guide Rev A b 2 23 Intentionally left blank...

Страница 3: ...6 Working with the D VERTER TM 7 Examples of installation 8 Starting the D Verter 9 The Keyboard 10 LCD Saver 10 The Menu 11 Operating instructions 13 DMX Control 14 RDM Control 15 Troubleshooting 17...

Страница 4: ...it refers so that the users will be aware of any potential danger before performing the task WARNING and CAUTION labels are key equipment parts Do not remove change or cover these labels If the label...

Страница 5: ...tion for our products Despite it all sometimes a little more is required due to the specifics of your project and installation We re looking forward to go that extra mile for you Contact us By Phone 1...

Страница 6: ...controllable via DMX or RDM this mechanical Fog Input Output Splitter can be used anywhere due to its universal switching power supply 100 250 VAC 50 60 Hz Its simple and efficient multi level User I...

Страница 7: ...e used indoor The D Verter can be used in two modes Dual output Control panel must be set facing towards the fog generator Dual input Control panel must be set facing away from the fog generator Fog D...

Страница 8: ...e output before activating the gate or stops rapidly the dispersion One ICE FOG Q Dual output This configuration allows setting two different output locations with the same ICE FOG Q Two Fog Generator...

Страница 9: ...a to 100 psi 689 kPa max Switch On the power The MDG D Verter TM will display during two 2 seconds the following message D Verter by MDG V x xx F y yyy where x xx is the version of your D Verter and y...

Страница 10: ...r level This key has no effect in the first level except when the length of value is too long If the displayed value starts with a this key will scroll the value to the left In a data input menu press...

Страница 11: ...ated by the program The user cannot modify them Items preceded by the character are control parameters The user within specific ranges or choices can MODIFY them In user input mode the value or the ch...

Страница 12: ...T side REVERSE DMX 128 for LEFT side DMX 128 for RIGHT side Comm Communication toggle The MDG D Verter is AUTO controlled by DMX RDM if a signal is present or locally if there is no signal LOCAL contr...

Страница 13: ...tput and loads the configuration parameters saved in the EEPROM memory At this point the MDG D Verter TM switches to stand by mode and most of the electronic controls are off Scroll to the Output menu...

Страница 14: ...a simple way to check if there is DMX signal The user can change the DMX Start Address in the Interface Menu DMX Add and choose any value between 1 and 512 512 last DMX channel The D Verter DMX interf...

Страница 15: ...ing device to discover and then configure monitor and manage intermediate and end devices connected through a DMX512 network RDM provides for intelligent control of devices on a DMX512 network which h...

Страница 16: ...ETAIL_ID_LIST 0x0070 Other 0x7FFF DEVICE_MODEL_DESCRIPTION 0x0080 Other 0x7FFF MANUFACTURER_LABEL 0x0081 MDG Fog Generators Ltd DEVICE_LABEL 0x0082 SOFTWARE_VERSION_LABEL 0x00C0 DMX_PERSONALITY 0x00E0...

Страница 17: ...ot move from one side to the other side Verify the gas bottle is opened Verify you have enough pressure at least 50 psi Verify the communication mode Comm You cannot control the MDG D Verter locally i...

Страница 18: ...Da 9 5 0 374 15 0 0 59 Cable Assembly 1 Put bushing and chuck onto the cable 2 Prepare cable as shown above 3 Insert the wire into the terminals and fasten the clamping device by a flat screw driver...

Страница 19: ...NVIRONMENTAL REQUIREMENTS Indoor use Dry room conditions 90 relative humidity 50 C 122 F non condensing 0 C to 50 C 32 F to 122 F operating temperature Dust free space Storage conditions 40 C to 60 C...

Страница 20: ...D Verter User Guide Rev A b 20 23 DIMENSIONS...

Страница 21: ...repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for any losses costs or damages...

Страница 22: ...D Verter User Guide Rev A b 22 23 DECLARATION OF CONFORMITY...

Страница 23: ...D Verter User Guide Rev A b 23 23 NOTES...