![MDG D-Verter Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/mdg/d-verter/d-verter_user-manual_1757283014.webp)
D-Verter
User Guide, Rev: A/b
14 / 23
DMX
C
ONTROL
The MDG
D-Verter
TM
can be controlled via a DMX512-A USITT standard protocol.
WARNING
Activating the
«DMX» mode («Comm.
DMX»)
, controls the MDG
D-Verter
TM
only by DMX signal. If the DMX wire is
unplugged
or DMX
signal is lost
, the MDG
D-Verter
TM
will stop
.
Activating the
«AUTO» mode («Comm.
AUTO»)
, controls MDG
D-Verter
TM
by
DMX, only if there is a signal. If the DMX wire is
unplugged
or DMX
signal is lost
,
the
MDG
D-Verter
TM
keeps the last DMX values
.
WARNING
In
«
AUTO Mode
»
, DMX commands always take precedence over Local commands.
The MDG
D-Verter
TM
provides a simple way to check if there is DMX signal:
The user can change the DMX Start Address in the Interface Menu («
DMX Add
»), and choose any
value between 1 and 512 (512, last DMX channel).
The
D-Verter
DMX interface uses one (1) channel, but has two personalities:
Personality NORMAL
DMX < 128
0 - 50%
the fog input (or output) is aligned to a fog output (or
input) on
RIGHT
side
DMX value
≥
128
50 - 100% the fog input (or output) switches to the
LEFT
side fog
output (or input).
Personality REVERSE
DMX < 128
0 - 50%
the fog input (or output) is aligned to a fog output (or
input) on
LEFT
side
DMX value
≥
128
50 - 100% the fog input (or output) switches to the
RIGHT
side
fog output (or input).
These channels have the same behaviour that the menus of the local interface (see
Operating
instructions
paragraph).
No DMX Signal
DMX Signal