D-Verter
User Guide, Rev: A/b
16 / 23
The RDM supported parameters implemented in the MDG
D-Verter
TM
are summarized in the
following table.
RDM Parameter ID’s
Value
GET
Allowed
SET
Allowed
Comments
DISC_UNIQUE_BRANCH
0x0001
DISC_MUTE
0x0002
DISC_UN_MUTE
0x0003
QUEUED_MESSAGE
0x0020
STATUS_MESSAGES
0x0030
SUPPORTED_PARAMETERS
0x0050
PARAMETER_DESCRIPTION
0x0051
DEVICE_INFO
0x0060
PRODUCT_DETAIL_ID_LIST
0x0070
Other (0x7FFF)
DEVICE_MODEL_DESCRIPTION
0x0080
Other (0x7FFF)
MANUFACTURER_LABEL
0x0081
MDG Fog Generators Ltd
DEVICE_LABEL
0x0082
SOFTWARE_VERSION_LABEL
0x00C0
DMX_PERSONALITY
0x00E0
2
DMX_PERSONALITY_DESCRIPTION 0x00E1
D-Verter (x1)
D-Verter Reverse (x1)
DMX_START_ADDRESS
0x00F0
1 to 512
SLOT_INFO
0x0120
SLOT_DESCRIPTION
0x0121
DEFAULT_SLOT_VALUE
0x0122
IDENTIFY_DEVICE
0x1000
LCD flashes
RESET_DEVICE
0x1001
0x01/0xFF Reset (Warm)
MDG_LCD_SAVER
0x8004
Unsigned Byte
(0=30 s,1=2 min, 2=Off)
MDG_COMM
0x8005
Unsigned Byte
(0=AUTO,1=LOCAL,
2=DMX)
Table 1: RDM Supported Parameters.