16
SWD-ED
CV-Table
S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable
CV
Description
S
L/S
Range
Note
1
Loco address
3
L
1
–
127
if CV 29 Bit 5 = 0 (automatically reset)
7
Software version
–
–
read only (10 = 1.0)
7
Decoder reset functions
3 ranges available
11
16
33
basic settings (CV 1,11-13,17-19,29-118)
programming lock (CV 15/16)
function- & Switch outputs (CV 119-129)
8
Manufacturer ID
160
–
read only
7+8
Register programming mode
Reg8 = CV-Address
Reg7 = CV-Value
CV 7/8 don’t changes his real va
lue
CV 8 write first with cv-number, then CV 7
write with value or read
(e.g.: CV 49 should have 3)
➔
CV 8 = 49, CV 7 = 3 writing
11
Analog timeout
30
30
–
255
1ms each value
15
Programming lock (key)
225
LS
0
–
255
to lock only change this value
16
Programming lock (lock)
225
LS
0
–
255
changes in CV 16 will change CV 15
17
Long loco address (high)
128
L
128
–
10239
activ only if CV 29 Bit 5 = 1
(automatically set if change CV 17/18)
18
Long loco address (low)
29
NMRA configuration
132
LS
bitwise programming (add value)
Bit
Value
OFF (Value 0)
ON
1
2
14 speed steps
28/128 speed steps
2
4
only digital operation
d analog operation
5
32
short loco address (CV 1)
long loco address (CV 17/18)
7
128
control with loco address
control with switch address
48
Switch address calculation
0
S
0/1
0 = Switch adress like norm
1 = Switch adress like Roco, Fleischmann
49
MD configuration
0*
LS
bitwise programming (add value)
Bit
Value
OFF (Value 0)
ON
0
1
Servo no defined position
Servo defined position
1
2
Servo
def. position „straight“
Servo def. position
„turned“
2
4
Servo normal output
Servo inverted output
3
8
Servo don
’
t hold endposition
Servo hold endposition
4
16
A1 normal output
A1 inverted output
5
32
A1 normal function
A1 heart polarisation
6
64
A1 normal function
A1 flashes while switching
7
128
A1 normal function
A1 autom. on if moving