20
PSD
CV-Table
S = Standard,
√
= Analog usable
CV
Description
S
√
Range
Note
7
Software version
–
–
read only (10 = 1.0)
7
Decoder reset functions
3 ranges available
11
16
33
basic settings (CV 1,11-13,17-19,29-119)
programming lock (CV 15/16)
switch outputs (CV 120-154)
8
Manufacturer ID
160
–
read only
7+8
Register programming mode
Reg8 = CV-Address
Reg7 = CV-Value
CV 7/8 don’t changes his real va
lue
CV 8 write first with cv-number, then CV 7
write with value or read
(e.g.: CV 49 should have 3)
➔
CV 8 = 49, CV 7 = 3 writing
15
Programming lock (key)
155
0
–
255
to lock only change this value
16
Programming lock (lock)
155
0
–
255
changes in CV 16 will change CV 15
29
NMRA configuration
132
√
0 = analog deactive, 132 = analog ok
48
Switch address calculation
0
0/1
0 = Switch adress like norm
1 = Switch adress like Roco, Fleischmann
49
MD configuration
0
√
bitwise programming
Bit
Value
OFF (Value 0)
ON
0
1
Engine normal output
Engine inverted output
1
2
Turn direction normal
Turn direction invers
2
4
A1 normal output
A1 inverted output
3
8
A2 normal output
A2 inverted output
4
16
A1 normal
A1 flashing while turning
114
Reverse loop module switch
current
25
√
1 - 100
current / 10 (25 = 2,5A)
115
Lock time reverse loop module
12
√
0
–
255
lock time for switching reverse loop module
time base 100 ms/value
Содержание mXion PSD