background image

 

PELLET STOVES 

Chapter 1

 

INSTALLATION AND USE MANUAL 

page

 7  

 

Warnings and guarantee conciliations 

   Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

 

 

 

Do  not  touch  the  stove  with  wet  hands,  in  view  of  the 

fact that it is an electrical appliance. Always disconnect 

the supply cable before doing anything to the unit. 

 

Before  carrying  out  any  cleaning  or  maintenance 

operation,  make  sure  in  advance  that  the  stove  is 

disconnected  from  the  mains  electricity  supply,  by 

turning  off  the  main  switch  located  on  the  back  of  the 

stove, or by unplugging the supply cable. 

 

The  stove  must  be  electrically  connected  to  a  system 

equipped with an effective earth conductor. 

 

The system must be of adequate rated capacity for the 

stated electrical power of the stove. 

 

Incorrect  installation  or  faulty  maintenance  (not 

conforming  to the requirements set out in this booklet) 

can cause harm to people, animals or property. In such 
cases  MCZ  is  absolved  from  any  civil  or  criminal 

responsibility.

 

 

1.2.  

OPERATING WARNINGS 

 

 

When using the device, comply with all local and 

national  laws  as  well  as  the  European  Standards 

in force locally, regionally and in the country. 

 

Shut  the  stove  down  in  the  event  of  a  breakdown  or 

bad running. 

 

Pellets must not be fed manually into the burner. 

 

Accumulated  unburnt  pellets  in  the  burner  after 

repeated  failed  ignitions  must  be  removed  before 

lighting. 

 

Do not wash the inside of the stove with water. 

 

Do not wash the stove with water. The water could get 

inside the unit and damage the electrical insulation and 

cause electric shocks. 

 

Do  not  expose  your  own  body  to  hot  air  for  extended 

periods.  Do  not  overheat  the  room  you  are  in  and 

where  the  stove  is  installed.  This  could  cause  injuries 

and health problems. 

 

Do not expose plants or animals directly to a current of 

hot air.  There could be harmful effects on them 

 

The device may not be used as an incinerator. 

 

Do not put any fuels in the hopper but wood pellets. 

 

Install  the  stove  in  a location with adequate means of  

fire-prevention  and  equipped  with  all  services  such  as 

power supply (air and electricity) and fume discharge. 

 

If there is a fire in the flue pipe, extinguish the stove, 

disconnect it from the power supply and never open the 

door. Then contact the competent authorities. 

 

If the stove and the ceramic cladding are in storage, it 

should  be  in  a  place  that  is  free  of  damp,  and  they 

should not be exposed to extremes of temperature. 

 

It is inadvisable to base the stove directly on the floor, 

and if the floor is made of flammable material, it must 

be suitably insulated. 

Содержание Kaika Oyster

Страница 1: ...Contents Technical service Rights reserved MCZ GROUP S p A Reproduction prohibited 8901148500 USE AND MAINTENANCE MANUAL...

Страница 2: ...SSEMBLY 16 3 1 DRAWINGS AND TECHNICAL CHARACTERISTICS 16 3 1 1 KAIKA Oyster 16 3 1 2 Technical characteristics 17 3 2 PREPARATION AND UNPACK ING 18 3 3 CLADDING ASSEMBLY 20 3 3 1 KAIKA STOVE 20 3 4 MA...

Страница 3: ...ernal thermostat and Eco Stop 41 5 4 7 Remote control accessory 42 5 4 7 1 General characteristics of the LCD remote control 43 5 4 7 2 Type of batteries and replacement 43 5 4 8 Hopper load ON OFF on...

Страница 4: ...t you read this booklet carefully before lighting the s tove for the first time While thanking you again may we remind you that the stove MUST NOT be used by children and that they must always be kept...

Страница 5: ...Indicates a sequence of buttons to be pushed to access menus or to make adjustments MANUAL Indicates that you should carefully read this manual or the related instructions IMPORTANT INFORMATION FOR CO...

Страница 6: ...amming must be carried out by adults Errors or incorrect settings may cause hazardous conditions and or poor operation Before beginning any operation the user or whoever is preparing to operate on the...

Страница 7: ...wn in the event of a breakdown or bad running Pellets must not be fed manually into the burner Accumulated unburnt pellets in the burner after repeated failed ignitions must be removed before lighting...

Страница 8: ...the date of purchase as proved by a supporting document which gives the name of the vendor and the date on which the sale took place The guarantee is conditional on the guarantee certificate being fi...

Страница 9: ...own in the instruction booklet especially those concerning warnings on the subject of installation use and maintenance of the appliance If the product does not perform correctly contact your local ret...

Страница 10: ...ion than is possible with fossil fuels pellets also have technical advantages While good quality timber has a calorific power of 4 4 kW kg with 15 moisture therefore after about 18 months seasoning th...

Страница 11: ...st be installed in a suitable position to allow the normal operations of opening and ordinary maintenance The site must be capable of providing the environmental conditions for operation equipped with...

Страница 12: ...her furniture their distance from the stove should be considerably increased 2 4 CONNECTION TO THE COMBURENT AIR INLET PIPE 1 Pipes and unions with suitable gaskets must always be used to guarantee a...

Страница 13: ...be used on the outside to avoid condensation The combustion chamber works in low pressure The smoke duct for the discharge of fumes will also be under low pressure when connected to an efficient flue...

Страница 14: ...ouble walled stainless steel smooth on the inside fixed to the wall Flexible stainless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking a...

Страница 15: ...luences the operation of the chimney indirectly by creating high pressure and low pressure zones not only outside the building but inside as well In rooms directly exposed to the wind 2 an indoor high...

Страница 16: ...UAL page 16 Installation and assembly Technical service Rights reserved MCZ GROUP S p A Reproduction prohibited 3 INSTALLATION AND ASSEMBLY 3 1 DRAWINGS AND TECHNICAL CHARACTERISTICS 3 1 1 KAIKA Oyste...

Страница 17: ...nd maximum 5 9 10 6 Mass of smoke 3 8 g sec Suggested draught at max power 0 10 mbar 10 Pa Suggested draught at min power 0 05 mbar 5 Pa Hopper capacity 20 litres Fuel pellet type Pellet diameter 6 8...

Страница 18: ...he stove body or unit must always be kept in a vertical position when moved and moved only using carts Special care must be used to protect the door and the glass from impacts that would damage them M...

Страница 19: ...he connecting pipe H Once the operations for connection are complete assemble the cladding ceramics or steel sides If the stove needs to be connected to a discharge pipe which goes through the rear wa...

Страница 20: ...and E two on the right and two on the left from bottom upwards Remove the back profile C already secured to the stove with three screws F G and H Take side B and insert it corresponding to the holes i...

Страница 21: ...AL CONNECTIONS Connect the supply cable first at the rear of the stove and then to an electrical outlet on the wall The main switch located on the rear of the stove should be switched on only when you...

Страница 22: ...hour of operation There are no health risks involved The stove will be subject to expansion and contraction during the stages of lighting and cooling down and may therefore make slight creaking noise...

Страница 23: ...in the hopper when empty it will hold about 10 kg This is easier if performed in two steps Pour half of the contents into the hopper and wait for the fuel to settle on the bottom Then pour in the res...

Страница 24: ...activated TIMER SLEEP AUTO ECO By pressing any of the 4 keys around the display C D E F you access the stove s operation settings screen level of the flame fan set temperature manual or automatic mode...

Страница 25: ...e as well as the identification code for any operating anomaly B ON OFF key or ESC exit the menu C Choice of air fan speed and menu scrolling D Access to the main menu and submenu E Choice of operatin...

Страница 26: ...urchased To switch the stove on and off press the key B for 2 seconds on the control panel or the A button on the remote control if purchased During the start up phase lasting about 15 minutes Pellet...

Страница 27: ...on the other hand lets you set the desired temperature in the room of installation The stove will control its power autonomously in order to reach and maintain the established temperature in the room...

Страница 28: ...until room temperature returns as desired once again and so on 4 8 2 1 AUTOMATIC MODE SETTING From the first screen with the word ON press any key and the screen with the word MENU will appear With t...

Страница 29: ...ected to the flame power with a maximum of V3 When such operation is selected the stove shall independently select fan speed according to flame power up to a maximum of V3 P1 V1 P2 V2 P3 V3 P4 V3 P5 V...

Страница 30: ...N OFF Hopper load ON OFF only displayed with stove off Technical menu accessible by a specialised MCZ technician password required o Stove type o Hours of Service o T Eco off o Parameters o Components...

Страница 31: ...cations made must be confirmed by pressing OK otherwise they will not be saved Key ESC takes you back to the previous screen If for 60 seconds the keypad of the control panel is inactive it returns to...

Страница 32: ...one or more programmes are active the panel alternatively displays the state of stove TIMER n where n is the number relating to the activated timer programmes separated by a dash Example TIMER 1 only...

Страница 33: ...sible to manually shutdown the stove by pressing the OFF key the stove shuts down and shall relight automatically at the next time foreseen by the timer 6 Equally in the stove off and timer active sta...

Страница 34: ...tdown time To confirm the choice press OK top right otherwise quit without saving any setting with ESC top left If the SLEEP function is active with TIMER active the former has priority so that the st...

Страница 35: ...e technical menu by an authorised MCZ technician During this phase on the small panel display remains ON ECO ACTIVE but the flame drops automatically by one power per minute until it reaches P1 and st...

Страница 36: ...en temperature higher than room temperature the apparatus shall continue to work at full power until the requested temperature is reached 5 4 3 Tones Panel display ON OFF This setting deactivates soun...

Страница 37: ...t all powers 3 15 increase in pellets at all powers 5 4 5 Changing the smoke exhaust fan speed Var smoke rpm In the installation proves difficult for smoke discharge lack of draught or even pressure i...

Страница 38: ...stove and it must be installed by a specialised technician WARNING The electrical wires must not be in contact with the hot parts of the stove The procedure to follow for the connection of the extern...

Страница 39: ...ith external thermostat In the SETTINGS THERMOSTAT MENU select ON and exit the menu at this point by selecting the AUTO operating mode para 4 8 2 in the place of the room temperature the word OFF will...

Страница 40: ...cture Technical service Rights reserved MCZ GROUP S p A Reproduction prohibited Esc Set Settings Mode Auto Menu Temp 22 C Fan A Esc Set Settings 21 0 C 21 04 OFF Esc OFF Set Thermostat Esc It Set Lang...

Страница 41: ...perature is achieved thermostat contact open the decrease in ECO shutdown T starts default 10 minutes changeable from inside the TECHNICAL MENU During this phase on the small panel display remains ON...

Страница 42: ...eases the flame s power level 5 Key that adjusts the speed of the hot air fan If the AUTO function key 7 activates this means that the ventilation is connected to the power 6 Key that adjusts the spee...

Страница 43: ...ecessary to extract the battery holder as shown on the figure on the back of the remote control and remove or insert the batteries following the symbols printed on the remote control and the battery i...

Страница 44: ...Man Menu Fire 5 Fan 5 Esc Set Time and date 21 0 C 21 04 OFF Esc Set Screw loading Esc It Set Language Esc Ok Screw loading Esc Enabled Screw loading 5 4 9 Technical menu A password used by an authori...

Страница 45: ...nalled TEMPORARY POWER CUT If there is a power outage during operation when the power comes back on the stove will go into cooling mode and then it will come back on automatically FAILURE TO LIGHT If...

Страница 46: ...he alarm persists contact technical support A09 Smoke temperature too high or smoke probe faulty Wait for the end of the cooling phase cancel the alarm and relight the stove placing the fuel load to m...

Страница 47: ...next point 2 It restores the stove to the operating condition before the blackout During phase 1 the panel displays RELIGHTING AFTER BLACKOUT During phase 2 the panel displays Lighting If during phase...

Страница 48: ...n the bottom If you use good quality pellets you will normally only need to use a paintbrush to restore the perfect condition of the component 7 1 2 Check every 2 3 days Clean and empty the ash drawer...

Страница 49: ...drawer M remove the grate N with the pellet deflector slightly raise the back H be careful because it can break easily and remove it Then remove the upper plate O leveraging on the guides X in the low...

Страница 50: ...STOVES Chapter 7 INSTALLATION AND USE MANUAL page 50 Maintenance and cleaning Technical service Rights reserved MCZ GROUP S p A Reproduction prohibited H N L M O y x Cleaning the exchanger KAIKA OYSTE...

Страница 51: ...tove we recommend completely removing pellets from the hopper with the use of a vacuum cleaner with an extension During periods of disuse the stove must be unplugged and placed in a dry place protecte...

Страница 52: ...nical service Rights reserved MCZ GROUP S p A Reproduction prohibited PARTS INTERVAL 1 DAY 2 3 DAYS 30 DAYS 90 DAYS 1 YEAR Grate Ash collection compartment Ash drawer Glass Lower heat exchanger Comple...

Страница 53: ...m Let the stove cool down completely reset the thermostat till lockout ceases relight stove if problem persists contact technical assistance Check if the timer setting is active Close the door or repl...

Страница 54: ...temperature Wait Remote control does not work if purchased optional Remote control batteries flat Remote control broken Replace batteries Replace remote control In the automatic position the stove alw...

Страница 55: ...manufacturer refuses to accept any responsibility for damage to persons and property that may arise The manufacturer furthermore refuses to accept responsibility for damage to persons and property ar...

Страница 56: ...RING KEY 1 Control panel 2 Room probe 3 Smoke probe red blue 4 Fuse 5 Switch 6 Sparkplug 7 Smoke exhaust fan 8 Gear motor 9 Contact thermostat 10 Air fan 11 Smoke exhaust fan revolution control white...

Страница 57: ...MCZ GROUP S p A Via La Croce n 8 33074 Vigonovo di Fontanafredda PN ITALY Telephone 0434 599599 r a Fax 0434 599598 Internet www mcz it e mail mcz mcz it 8901148500 Rev 1 05 2013...

Отзывы: