PELLET STOVES
Chapter 5
INSTALLATION AND USE MANUAL
page
38
Menu structure
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
CAVO TERMOSTATO
AMBIENTE
POS.14
5.4.6.
Connection to an additional room thermostat
The stove has a probe that detects the room temperature, see
chap.4.10, but it is also possible to install an additional external room
thermostat in the area where the stove is used.
The external room thermostat is not included with the
stove and it must be installed by a specialised
technician.
WARNING!
The electrical wires must not be in contact with the
hot parts of the stove.
The procedure to follow for the connection of the external thermostat is
the following:
Connect the two wires of the cable which come from the room
temperature to the two free terminals of the connector
(
position
13
wiring diagram chap.9). To do this it is necessary
to:
o
Access the card (see par. 5.4.6.1)
o
Pass the two external room thermostat wires through
the hole
T
o
Pull the two wires to carry out connection to the board
corresponding to terminal 13 (see chap.9)
o
Fix the card to the stove again.
THERMOSTAT CABLE
POS.13