background image

 

INSTALLATION AND USE MANUAL 

Chapter 2

 

page

 8  

 

Theoretical notions for installation 

Technical service – MCZ GROUP S.p.A. all rights reserved - Reproduction prohibited 

 

2. 

INSTALLATION IN ACCORDANCE WITH UNI 

10683 

2.1.  

OPERATING AREA 

For  good  operations  and  good  heat  distribution,  the  fireplace  stove 

should  be positioned  in a place where the air required for combustion 

can flow (at least 60 m

3

/h must be available) according to installation 

standards and current regulations in the country of installation. 
 

The room volume must not be less than 60 m

3

.  

 
Air  must  enter  through  permanent  apertures  on  the  walls  (near  the 
fireplace stove) that open outdoors with a minimum section of 360 cm

2

These apertures (air vents) must be made so as not to be obstructed in 

any way. 
Air  can  also  be  taken  from  adjacent  rooms  as  long  as  these  are 

equipped  with  outdoor  air  vents  and  not  bedrooms  or  bathrooms  or 

rooms  where  fire  hazards  do  not  exist  such  as  garages,  wood  sheds, 

flammable  material  warehouses,  strictly  observing  the  provisions  of 

current regulations. 
 

 

 

Fireplace  stoves  may  not  be  installed  in 

bedrooms,  bathrooms  and  where  another 

heating  device  is  installed  without  autonomous 

air flow (fireplace, stove, etc.). 

 

Placing  the  fireplace  stove  in  explosive 

environments is prohibited. 

 

The  floor  of  the  room  where  the  fireplace  stove 

is  to  be  installed  must  be  strong  enough  to 

support its weight. 

 

In  the  event  of  wood  floors,  install  a  protective 

covering  in  accordance  with  current  regulations 

in the country of installation. 

 

If  walls  are  not  flammable,  install  the  fireplace 

stove at least 5 cm from the walls. 

 

2.2.  

PRECAUTIONS 

The fireplace stove must be installed in a suitable surface that permits 
routine opening and maintenance operations.  
The room must be: 

 

suitable for room operating conditions 

 

equipped with power supply  230V  50 Hz  

 

equipped with an adequate smoke exhaust system 

 

equipped with outdoor ventilation 

 

provided with an earth connection complying with CEI 64-8 

 

Содержание Forma Series

Страница 1: ...INSTALLATION AND USE MANUAL EN...

Страница 2: ...ATION AND ASSEMBLY 16 4 1 PREPARATION AND UNPACKING 16 4 2 POSITIONING 16 4 3 HEIGHT ADJUSTMENT 17 4 4 RELEASE OF COUNTERWEIGHTS 17 4 5 PLUMBING CONNECTION 18 4 5 1 Water characteristics 18 4 5 2 Hydr...

Страница 3: ...TO BE PERFORMED BY THE USER 30 6 1 1 Cleaning the glass 30 6 1 2 Cleaning the exchanger 30 6 1 3 Cleaning out the ashes 30 6 1 4 Cleaning flue pipe 31 6 1 5 Lubrication and routine maintenance of the...

Страница 4: ...out prior notice Reproduction even partial of this manual without the Manufacturer s authorisation is prohibited Manual preservation Please take care of this manual and keep it in a place that can be...

Страница 5: ...ervision Only use the fuel recommended by MCZ The appliance must not be used as an incinerator The use of liquid fuel is strictly forbidden The instructions provided in this manual must always be comp...

Страница 6: ...to the fireplace stove If the chimney flue draught is poor due to bad weather or improper installation start the fire decisively while keeping the door slightly ajar When you close the door keep the...

Страница 7: ...aused directly or indirectly by persons animals or things as a result of the failure to observe all the provisions set forth in the instruction booklet especially those concerning warnings on the subj...

Страница 8: ...ooms or rooms where fire hazards do not exist such as garages wood sheds flammable material warehouses strictly observing the provisions of current regulations Fireplace stoves may not be installed in...

Страница 9: ...ding to UNI 10683 For this purpose drill a hole with minimum 360 cm free section near the fireplace stove 22 cm diameter or a 20x18cm rectangle protected by an indoor and outdoor grille The air intake...

Страница 10: ...are used they must be insulated with suitable material such as ceramic fibre matting to avoid deterioration of the masonry and of the decorative hood liner IMPORTANT Any increase in the section of the...

Страница 11: ...uitably sized in accordance with EN13384 1 The smoke duct should be equipped with a solid material collection chamber at the mouth of the smoke duct to be easily opened with an airtight door IMPORTANT...

Страница 12: ...lt to prevent rain snow and any foreign objects from getting into the flue pipe They must be installed to guarantee adequate smoke dispersion and out of the reflux area where negative pressure forms F...

Страница 13: ...072 kcal h Efficiency 77 1 Heatable volume m3 563 40 644 35 751 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 333 C Smoke outlet 25 cm Net weight 232 kg Hydrotherm 80 235 Kg Hydrotherm 80E...

Страница 14: ...me m3 456 40 521 35 608 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 310 C Smoke outlet 20 cm Net weight 195 kg Hydrotherm 70 212 Kg Hydrotherm 70V External combustion air inlet cm 150 CO...

Страница 15: ...ut power H2O 13 0 kW 11 180 kcal h Efficiency 75 2 Heatable volume m3 456 40 521 35 608 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 310 C Smoke outlet 20 cm Net weight 204 kg External com...

Страница 16: ...taking care that its position complies with the above instructions The fireplace stove must always be kept VERTICAL while moving and only using hand trucks Do not drag the unit as this may damage the...

Страница 17: ...y pedestal to set the product on Do not eliminate the feet They are indispensable for levelling If the fireplace stove is not placed level there is the risk that door will not close perfectly and that...

Страница 18: ...of hard water being used it is advisable to install a softener filter 4 5 1 Water characteristics The characteristics of the water used to fill the system are very important to prevent the build up of...

Страница 19: ...tank must feature no shut off valve or unneeded curves Both the open expansion tank and the vent tube must be protected against the cold 4 5 3 Hydraulic connection with Closed Tank In order to achieve...

Страница 20: ...accessory This is a device that limits the water temperature In case of boiler overheating it activates an emergency exchanger that causes the immediate cooling of the water Its use is regulated by th...

Страница 21: ...sons any cut off valves placed upstream of the valve must be open You should install a pressure reducer at the inlet of water from the water mains The reducer must be calibrated at 2 bars at least and...

Страница 22: ...is located that lets you perform the purging operations and check the function It is necessary for a technician check the function of the valve at least once a year 4 7 5 Safety MCZ SHALL NOT BE HELD...

Страница 23: ...raulic connections pay attention not to mechanically over stress the thread of the valve body In time it is possible that breakages may occur with hydraulic leaks damaging people and or objects A wate...

Страница 24: ...damaged or catch fire walls made of wood plasterboard etc 4 8 2 INSULATING A WOODEN BEAM The wood beam must be protected with adequate insulation from heated parts to prevent the risk of fire or damag...

Страница 25: ...not stay near the fireplace stove and as previously mentioned ventilate the room The smoke and the smell of paint will vanish after about one hour of operation There are no health risks involved The...

Страница 26: ...r after a lighting at full power has occurred a few times Make sure you have read and completely understood the contents of this instruction booklet Remove any components which might burn from the fir...

Страница 27: ...or polluting substances Do not burn rubbish The gases produced by combustion due the use of unsuitable fuels cause damage to the fireplace stove and the chimney they cause pollution and can compromise...

Страница 28: ...al that can dirty glass faster Also the low performance of the flue pipe can jeopardise glass cleanliness since smoke remains in the combustion chamber longer than normal 5 6 FIRST LIGHTING It is advi...

Страница 29: ...be cleaned During use the metal parts and the glass reach high temperatures For all jobs of loading the stove adjustment or cleaning the ash drawer use the insulating glove provided Never leave childr...

Страница 30: ...1 2 Cleaning the exchanger A scraper is provided to remove the creosote that may form in the exchanger when the fireplace stove is cold the creosote is black shiny flaky and easy to remove The advice...

Страница 31: ...ase both runners as follows Pull open the frame liner and extract the door so you can see the tracks of the guide Using the provided grease gun apply two drops of grease about 5 mm in diameter at the...

Страница 32: ...AL WEIGHT KIT 7 1 Supplementary weight kits for door closure only available for closed tank version A supplementary weight kit is available as an accessory to be fixed above the door with this system...

Страница 33: ...MCZ GROUP S p A Via La Croce 8 33074 Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 PBX Fax 39 0434 599598 Internet www mcz it e mail mcz mcz it 8901158500 Rev 1 01 2016...

Отзывы: