MCZ Forma Series Скачать руководство пользователя страница 18

 

INSTALLATION AND USE MANUAL 

Chapter 4 

page

 18  

 

Operation 

                   Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited 

 

4.5.  

PLUMBING CONNECTION 

  

MCZ  shall  not  be  held  liable  for  damage  due  to 

incorrect  connections  or  connections  made  by 

unqualified personnel 

 

  

 

IMPORTANT !! 
The water system must be connected and the perfect 

seal of the boiler must be checked also when the fire 

is lit, before cladding the fireplace stove.  
Failure  to  comply  with  the  installation  instructions 

shall  make  the  product guarantee void and lift  MCZ 

from  any  involvement  concerning  any  damage  to 

people and objects. 
In light of the above, MCZ shall not be held liable for 

any  possible  break  of  the  cladding  in  case  the 

compulsory  preventive  operating  checks  are  not 

performed. 

 

  

To  minimise  the  formation  of  limescale  in  the  ducts, 

in  case  of  hard  water  being  used,  it  is  advisable  to 

install a softener filter. 

4.5.1.  

Water characteristics 

The  characteristics  of  the  water  used  to  fill  the  system  are  very 

important to prevent the build-up of mineral salts and the formation of 

incrustations along the pipes, in the boiler and in the heat exchangers. 

Therefore, 

please 

GET 

YOUR 

PLUMBER'S 

ADVICE 

CONCERNING: 
 

 

 

 

Hardness of water  circulating  in the system, to prevent 

problems of incrustation and limescale, especially in the 

domestic water heat exchanger. (> 25° French) 

 

Installation  of  a  water  softener  (if  water  hardness 

exceeds 25° French) 

 

Filling the system with treated water (demineralised). 

 

Possibly providing an anti-condensation circuit. 

 

Installation  of  plumbing  bumpers  to  prevent  banging 

along the fittings and pipes. 

 

 
If  you  have  very extensive systems, with a large amount of water, or 

which  require  frequent  refilling,  the  installation  of  water  softening 

systems. 

 

  

It  should  be  remembered  that  incrustations 

drastically  reduce  performance  due  to  low  thermal 

conductivity. 

 

Содержание Forma Series

Страница 1: ...INSTALLATION AND USE MANUAL EN...

Страница 2: ...ATION AND ASSEMBLY 16 4 1 PREPARATION AND UNPACKING 16 4 2 POSITIONING 16 4 3 HEIGHT ADJUSTMENT 17 4 4 RELEASE OF COUNTERWEIGHTS 17 4 5 PLUMBING CONNECTION 18 4 5 1 Water characteristics 18 4 5 2 Hydr...

Страница 3: ...TO BE PERFORMED BY THE USER 30 6 1 1 Cleaning the glass 30 6 1 2 Cleaning the exchanger 30 6 1 3 Cleaning out the ashes 30 6 1 4 Cleaning flue pipe 31 6 1 5 Lubrication and routine maintenance of the...

Страница 4: ...out prior notice Reproduction even partial of this manual without the Manufacturer s authorisation is prohibited Manual preservation Please take care of this manual and keep it in a place that can be...

Страница 5: ...ervision Only use the fuel recommended by MCZ The appliance must not be used as an incinerator The use of liquid fuel is strictly forbidden The instructions provided in this manual must always be comp...

Страница 6: ...to the fireplace stove If the chimney flue draught is poor due to bad weather or improper installation start the fire decisively while keeping the door slightly ajar When you close the door keep the...

Страница 7: ...aused directly or indirectly by persons animals or things as a result of the failure to observe all the provisions set forth in the instruction booklet especially those concerning warnings on the subj...

Страница 8: ...ooms or rooms where fire hazards do not exist such as garages wood sheds flammable material warehouses strictly observing the provisions of current regulations Fireplace stoves may not be installed in...

Страница 9: ...ding to UNI 10683 For this purpose drill a hole with minimum 360 cm free section near the fireplace stove 22 cm diameter or a 20x18cm rectangle protected by an indoor and outdoor grille The air intake...

Страница 10: ...are used they must be insulated with suitable material such as ceramic fibre matting to avoid deterioration of the masonry and of the decorative hood liner IMPORTANT Any increase in the section of the...

Страница 11: ...uitably sized in accordance with EN13384 1 The smoke duct should be equipped with a solid material collection chamber at the mouth of the smoke duct to be easily opened with an airtight door IMPORTANT...

Страница 12: ...lt to prevent rain snow and any foreign objects from getting into the flue pipe They must be installed to guarantee adequate smoke dispersion and out of the reflux area where negative pressure forms F...

Страница 13: ...072 kcal h Efficiency 77 1 Heatable volume m3 563 40 644 35 751 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 333 C Smoke outlet 25 cm Net weight 232 kg Hydrotherm 80 235 Kg Hydrotherm 80E...

Страница 14: ...me m3 456 40 521 35 608 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 310 C Smoke outlet 20 cm Net weight 195 kg Hydrotherm 70 212 Kg Hydrotherm 70V External combustion air inlet cm 150 CO...

Страница 15: ...ut power H2O 13 0 kW 11 180 kcal h Efficiency 75 2 Heatable volume m3 456 40 521 35 608 30 Recommended draught 12 Pa 0 12 mbar Smoke temperature 310 C Smoke outlet 20 cm Net weight 204 kg External com...

Страница 16: ...taking care that its position complies with the above instructions The fireplace stove must always be kept VERTICAL while moving and only using hand trucks Do not drag the unit as this may damage the...

Страница 17: ...y pedestal to set the product on Do not eliminate the feet They are indispensable for levelling If the fireplace stove is not placed level there is the risk that door will not close perfectly and that...

Страница 18: ...of hard water being used it is advisable to install a softener filter 4 5 1 Water characteristics The characteristics of the water used to fill the system are very important to prevent the build up of...

Страница 19: ...tank must feature no shut off valve or unneeded curves Both the open expansion tank and the vent tube must be protected against the cold 4 5 3 Hydraulic connection with Closed Tank In order to achieve...

Страница 20: ...accessory This is a device that limits the water temperature In case of boiler overheating it activates an emergency exchanger that causes the immediate cooling of the water Its use is regulated by th...

Страница 21: ...sons any cut off valves placed upstream of the valve must be open You should install a pressure reducer at the inlet of water from the water mains The reducer must be calibrated at 2 bars at least and...

Страница 22: ...is located that lets you perform the purging operations and check the function It is necessary for a technician check the function of the valve at least once a year 4 7 5 Safety MCZ SHALL NOT BE HELD...

Страница 23: ...raulic connections pay attention not to mechanically over stress the thread of the valve body In time it is possible that breakages may occur with hydraulic leaks damaging people and or objects A wate...

Страница 24: ...damaged or catch fire walls made of wood plasterboard etc 4 8 2 INSULATING A WOODEN BEAM The wood beam must be protected with adequate insulation from heated parts to prevent the risk of fire or damag...

Страница 25: ...not stay near the fireplace stove and as previously mentioned ventilate the room The smoke and the smell of paint will vanish after about one hour of operation There are no health risks involved The...

Страница 26: ...r after a lighting at full power has occurred a few times Make sure you have read and completely understood the contents of this instruction booklet Remove any components which might burn from the fir...

Страница 27: ...or polluting substances Do not burn rubbish The gases produced by combustion due the use of unsuitable fuels cause damage to the fireplace stove and the chimney they cause pollution and can compromise...

Страница 28: ...al that can dirty glass faster Also the low performance of the flue pipe can jeopardise glass cleanliness since smoke remains in the combustion chamber longer than normal 5 6 FIRST LIGHTING It is advi...

Страница 29: ...be cleaned During use the metal parts and the glass reach high temperatures For all jobs of loading the stove adjustment or cleaning the ash drawer use the insulating glove provided Never leave childr...

Страница 30: ...1 2 Cleaning the exchanger A scraper is provided to remove the creosote that may form in the exchanger when the fireplace stove is cold the creosote is black shiny flaky and easy to remove The advice...

Страница 31: ...ase both runners as follows Pull open the frame liner and extract the door so you can see the tracks of the guide Using the provided grease gun apply two drops of grease about 5 mm in diameter at the...

Страница 32: ...AL WEIGHT KIT 7 1 Supplementary weight kits for door closure only available for closed tank version A supplementary weight kit is available as an accessory to be fixed above the door with this system...

Страница 33: ...MCZ GROUP S p A Via La Croce 8 33074 Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 PBX Fax 39 0434 599598 Internet www mcz it e mail mcz mcz it 8901158500 Rev 1 01 2016...

Отзывы: