Accessory Parts
Fresh Air Intake for MCK-A Model
Short Duct Specification
•
The indoor unit is provided with air discharge and air intake "knock-out". hole for duct connection.
However the connection of the short duct for air discharge is possible on only one side.
•
The use of short duct for air discharge will improve airflow distribution if there is an obstruction (such
as alighting fixture) or in a long, narrow room or an L-shaped room. It is also used for air conditioning
of two rooms simultaneously.
Possible Direction for Air Discharge and Air Intake
AIR DISCHARGE
AIR DISCHARGE
AIR INTAKE
Possible Opening Dimension for Duct Connection
Note :
1. Avoid to use the short duct on which the air discharge grille can be completely closed, to prevent
evaporator freezing.
2.
In order to prevent condensation forming, be sure that there is sufficient thermal insulation and no
leakage of cool air when installing the short duct.
3. Keep the introduction of fresh air intake within 20% of total air flow. Also provide a chamber and
use a booster fan.
82
Содержание MCK 010C
Страница 19: ...CK20B BR NC Curves CK15B BR NC Curves 18...
Страница 20: ...CK30B BR NC Curves CK25B BR NC Curves 19...
Страница 44: ...Outdoor Unit MLC030 040 050C CR M4LC030 040 050C CR 43...
Страница 46: ...Indoor Unit Cooling Only Model MCK030A Outdoor Unit Model MLC030B 45...
Страница 47: ...Indoor Unit Cooling Only Model MCK030A Outdoor Unit Model MLC M4LC030C 46...
Страница 48: ...Indoor Unit Cooling Only Model MCK040A Outdoor Unit Model MLC035C 47...
Страница 49: ...Indoor Unit Cooling Only Model MCK040 050A Outdoor Unit Model MLC M4LC040 050C 48...
Страница 51: ...Indoor Unit Heat Pump Model MCK030AR Outdoor Unit Model MLC030BR 50...
Страница 52: ...Indoor Unit Heat Pump Model MCK030AR M4LC030CR Outdoor Unit Model MLC 51...
Страница 53: ...Indoor Unit Heat Pump Model MCK040AR Outdoor Unit Model MLC035CR 52...
Страница 54: ...Indoor Unit Heat Pump Model MCK040 050AR Outdoor Unit Model MLC M4LC040 050CR 53...
Страница 55: ...Indoor Unit Cooling Only Model MCK015B Outdoor Unit Model MLC015B 54...
Страница 56: ...Indoor Unit Cooling Only Model MCK020 025B Outdoor Unit Model MLC020 025B 55...
Страница 57: ...Indoor Unit Cooling Only Model MCK030B Outdoor Unit Model MLC030C 56...
Страница 58: ...Indoor Unit Cooling Only Model MCK030B Outdoor Unit Model MLC030B 57...
Страница 59: ...Indoor Unit Heat Pump Model MCK015BR Outdoor Unit Model MLC015BR 58...
Страница 60: ...Indoor Unit Heat Pump Model MCK020 025BR Outdoor Unit Model MLC020 025BR 59...
Страница 61: ...Indoor Unit Heat Pump Model MCK030BR Outdoor Unit Model MLC030BR 60...
Страница 62: ...Indoor Unit Heat Pump Model MCK030BR Outdoor Unit Model MLC030CR 61...
Страница 63: ...Indoor Unit Cooling Only Model MCK010 015C Outdoor Unit Model MLC010 015B 62...
Страница 64: ...Indoor Unit Cooling Only Model MCK020C Outdoor Unit Model MLC020B 63...
Страница 67: ...Model MLC M4LC020 025BR Heat Pump 3 Phase 50HZ 380 415V Model MLC M4LC030CR Heat Pump 3 Phase 50HZ 380 415V 66...
Страница 70: ...Low Ambient Unit Optional Outdoor Unit Model MLC010B 015B 50HZ Outdoor Unit Model MLC020B 025B 50HZ 69...
Страница 72: ...Single Phase for 4HP Outdoor Unit Model MLC M4LC040C Cooling Only Model MLC M4LC040CR Heat Pump 71...
Страница 100: ...Fresh Air Kit for MCK C Models 99...
Страница 101: ...2004 McQuay International 1 800 432 1342 www mcquay com ISO 9002 REGISTERED...