background image

IM 1068 / Page 12 of 32

 

 

P

  in. 

45

3

37 

25

1

2

  24

1

2

  13

11

16

  22

7

8

 

10 

16 

4

1

2

 

1

1

2

 

14

3

4

 

1

3

4

  mm

  1162  940 

648 

622 

348 

581 

254 

406 

114 

38 

375 

44

 

Notes:

  See Detail A, B, C, D, E. F, G, or H on page 7 for dimensions of factory installed valve and return piping stub.

  Junction box 7/8" (22mm) diameter knockouts for 1/2" (12mm) conduit. 

  See Table 9 for dimension B.

Figure 14: Hydronic Heat Section with Short Control Box (Sizes 007-012)

The short control box is used with standard unit mounted manual changeover control, and unit mounted manual changeover with 

emergency standby (ESB) power supply.

Side View

Room Cabinet Removed

Front View

A

M

J

K

L

D

Junction Box 

8"

(203mm)

Short

Control Box

Room 

Cabinet

Room Cabinet

Mounting Holes (4)

1

2

''

(12mm)

1

4

''

(6mm)

G

F

B

P

N

E

Wall Box

Hydronic    Coil

H

Table 8: Hydronic Heat Section with Short Control Box Dimensions

Units With Hydronic Heat (Sizes 007–012)

The hydronic heat section can be supplied with a short (4¼''

high) control box or a long (13½'' high) control box 

depending on the number of options selected. Observe the 

control box to determine which one was supplied for the job.

Short Control Box

If the short control box was supplied, field wiring should be 

brought into the 2'' x 4'' junction box which is located on the 

right-hand side of the heat section (Figure 14.)

Long Control Box

1.  If the long control box was provided, make electrical

 

connections to a field supplied junction box that should 

be fastened to the floor beneath the control 

 

(Figure 15).

2.  Locate the long control box. The power wires for the

 

control extend through the piece of flexible conduit that

 

exits from the bottom of the control. These wires should 

be connected to the incoming power at the junction box

 

installed in Step 1.

Remote Control — For units with remote mounted

thermostat, refer to page 14.

Table 9: Wall Box “B” Dimensions

 

Wall Box 

Size

 

2

1

2

3

1

2

"

  

4" 

5" 

6" 

7" 

8" 

9" 

10"

 

“B” Dimension 

007–012

 

64 mm 

89 mm 

102 mm 

127 mm 

152 mm 

178 mm 

203 mm 

229 mm 

254 mm

Содержание Incremental Packaged Terminal

Страница 1: ...Incremental Packaged Terminal Air Conditioner Incremental Room Conditioner with R 410A Refrigerant Group PTAC Part No 669729001 Date March 2010 Installation Maintenance Data IM 1068 2010 McQuay Intern...

Страница 2: ...thisequipmentshallbeinaccordancewiththe regulations of authorities having jurisdiction and all applicable codes It is the responsibility of the installer to determine and follow the applicable codes S...

Страница 3: ...9000 Voltage A 115 60 1 C 208 60 1 G 230 60 1 J 277 265 60 1 S 208 115 60 1 R 265 115 60 1 Coil Options Z None Heating Options 35 2 5 kW nominal 41 3 5 kW nominal 44 4 0 kW nominal 48 5 0 kW nominal 5...

Страница 4: ...floor line to clear obstructions Without cabinet modifications the wall box can be placed up to 1 25mm abovethefloor Thestandardadjustablekickplatecan be telescoped to hide the space below the wall b...

Страница 5: ...nstructions will vary by depth of wall but not by wall material Do not remove the weather panel at any time during the installation of the wall box Premature removal of this panel could result in impr...

Страница 6: ...e Type K cooling chassis but packaged and shipped separately Check the heat section carton label and the unit s nameplate to ensure it is correct for the cooling chassis and the space The following st...

Страница 7: ...exposed water or steam lines that are located within the room cabinet Failure to do this may cause erratic operation of the thermostat 10 Protect the heat section from damage during construction Do n...

Страница 8: ...turn piping for steam or hot water is supplied from right hand side only Hot water must be supplied to the bottom of the coil and steam to the top of the coil 2 To simplify the steam or hot water conn...

Страница 9: ...e condenser fan wheel to be sure that there is no interference or looseness If it is loose tighten the setscrew located over the center of the flat on the motor shaft Do not lubricate condenser fan mo...

Страница 10: ...e the equipment is connected to the proper power supply and that proper fusing is used 2 In cases where a number of conditioners are to be installed single circuits should be provided for each machine...

Страница 11: ...H Edge of Wall Box Long Control Box Cool Chassis Power Cord Heat Section Power Cord Wall Box End View w o Cabinet B A H D F G 91 4 203 mm Figure 13 Electric Heat Section Size 019 Notes Guest room con...

Страница 12: ...Sizes 007 012 The hydronic heat section can be supplied with a short 4 high control box or a long 13 high control box depending on the number of options selected Observe the control box to determine w...

Страница 13: ...ion B The long control box is used with optional special controls such as Guest Room Control GRC Night Setback NSB and remote thermostats Note Left hand piping must be used with the long control box d...

Страница 14: ...at section and cool chassis and push the cabinet firmly against the wall The discharge grille seals should rest on the discharge opening of the heat section For unit size 019 Position the room cabinet...

Страница 15: ...Start up Initial start up of the McQuay equipment by an experienced person is usually the responsibility of the installing contractor This consists of inspecting and operating the equipment for all f...

Страница 16: ...slave unit as shown in Figure 22 The master unit is furnished with a 50 VA transformer that is capable of handling up to 7 slave units If additional slave units are to be added a larger field supplie...

Страница 17: ...Setback NSB R4 Relay Guest Room Control GRC R5 Relay Hot Water Valve R6 Relay Control R7 Relay Night Setback NSB S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transform...

Страница 18: ...P4 Plug on Master Wire Harness P5 Plug on Master Wire Harness R1 Relay Run R2 Relay Outdoor Fan Motor R3 Relay Cooling R4 Relay Indoor Fan Motor R5 Relay Heating 1st Stage R6 Relay Heating 2nd Stage...

Страница 19: ...R4 Relay Guest Room Control GRC R5 Relay Hot Water Valve R6 Relay Control R7 Relay Night Setback NSB S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Term...

Страница 20: ...Master Wire Harness R1 Relay Run R2 Relay Outdoor Fan Motor R3 Relay Cooling R4 Relay Indoor Fan Motor R5 Relay Heating 1st Stage R6 Relay Heating 2nd Stage R7 Relay Night Setback NSB R9 Relay Hot Wa...

Страница 21: ...4 Relay Guest Room Control GRC R5 Relay Hot Water Valve R6 Relay Control R7 Relay Night Setback NSB S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Termin...

Страница 22: ...n Master Wire Harness R1 Relay Run R2 Relay Outdoor Fan Motor R3 Relay Cooling R4 Relay Indoor Fan Motor R5 Relay Heating 1st Stage R6 Relay Heating 2nd Stage R7 Relay Night Setback NSB R9 Relay Hot W...

Страница 23: ...ol GRC R5 Relay Hot Water Valve R6 Relay Control R7 Relay Night Setback NSB S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block Control Box TB2 Terminal Board 24...

Страница 24: ...Relay Hot Water Valve R6 Relay Control R7 Relay Night Setback NSB S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block Control Box TB2 Terminal...

Страница 25: ...R5 Relay Hot Water Valve R6 Relay Control R7 Relay Night Setback NSB S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block Control Box TB2 Termin...

Страница 26: ...oil lightly to enhance dust collecting ability The Type K is also available with a carbon filter a zeolite filter or electrostatic filter The electrostatic filter is renewable by rinsing with hot wate...

Страница 27: ...fective part can then be returned to McQuay International or one of its authorized service stations So long as it is still in warranty it is repaired or replaced and returned to the owner without cost...

Страница 28: ...a short interval 4 Blowers run on Cool and compressor starts and runs but compressor occasionally stops on overload device 5 Compressor starts and runs on Cool but blowers do not run 6 Compressor star...

Страница 29: ...a short circuit or a grounded condition in the circuit c Replace d Replace wire or tighten e Adjust rotate knob to Warm f Replace g Replace h 1 Temporarily lock valve open replace 2 Replace 8 Insuffic...

Страница 30: ...Control Size 007 65 lbs Size 009 65 lbs Size 012 65 lbs Size 019 77 lbs Electric Heat Section With Control Size 007 60 lbs Size 009 60 lbs Size 012 60 lbs Size 019 70 lbs Wall Box With Rear Extension...

Страница 31: ...IM 1068 Page 31 of 32...

Страница 32: ...ranty details Refer to Form 933 43285Y To find your local McQuay Representative go to www mcquay com This document contains the most current product information as of this printing For the most up to...

Отзывы: