Auto Mode Time Periods Parameter Setting 

 

In normal working interface, short press S1 to enter into time periods setting. Four time 

periods can be set for each day of the whole week.   

 

Press S2 can switch among “Hours, Minutes, Temperature value”. Press S4 or S5 can change 

the value.   

 

After finished the setting of 4 time periods on Monday, press S1 and follow the same way to 

set periods of next days. 

 

After all periods set, press S1 /S2 or wait 25 seconds without any key operation will save the 

setting and return to normal display. Device will operate in accordance with the new setting. 

 

The default setting is as follow: 

 

 

High temperature protection    (For MH7-EH Electrical Heating ONLY) 

        When external temperature sensor detect the temperature value

55

, device will open high 

temperature  protection,  electric  heating  will  be  forced  off,  and  high  temperature  protection  icon 

displays. 

        When external temperature sensor detect the temperature value

50 

, device will return to 

normal work, high temperature protection icon disappears. 

 

Anti-freeze protection function: (Optional) 

 

In shutdown interface:   

    When  the  built-in  temperature  sensor  detect  the  temperature  value

5

,  device  will  open 

anti-freeze  protection,  electric  heating  will  be  forced  open,  and  anti-freeze  protection  icon 

displays. 

When  the  built-in  temperature  sensor  detect  the  temperature  value

,  device  will  turn 

off anti-freeze protection and return to normal work, anti-freeze icon disappears. 

 

Note: If MH7 thermostat do not connect with an external temperature sensor, it will only display 

the  indoor  temperature  icon;  If  MH7  thermostat  connect  with  an  external  temperature  sensor,  it 

will display  the  indoor  temperature and high temperature protection icon; When it  is  under high 

temperature protection, high temperature protection icon flickers. 

 

Z-Wave Operation 

 

Including & Excluding of Z-Wave network 

        In normal working interface, press & hold S4 to enter interface for inclusion or exclusion of 

Z-Wave  network.  Before  device  included  into  network,  “-  -  -”  will  display  on  the  screen.  Then 

press S4 once, device will enter learning mode to get a node ID. If inclusion is success, a node ID 

will display on the screen in a few seconds.   

        A node ID can always inform us whether the device is in the network or not. 

Week\Periods 

Period 1 

Period 2 

Period 3 

Period 4 

Mon~Fri 

5:00      18

 

7:00      16

 

16:00    22

 

21:00    16

 

Sat~Sun 

6:00      18

 

8:00      16

 

16:00    22

 

21:00    16

 

Содержание MH7-WH

Страница 1: ...16A Self Consumption 1W Internal Temp Sensor NTC 15K External Temp Sensor optional NTC R25 15K B25 50 3550K Working Environment 0 50 0 90 RH Non condensation Temperature Setting 5 37 41 99 Adjustable...

Страница 2: ...nsert all wires into the right terminals and tighten screws Wiring diagrams are shown below Step 3 Push the bottom into the junction box and secure it with two screws and then mount the touch panel ba...

Страница 3: ...current week local time working mode current temperature output status etc Note After the backlit goes out please press the button to light up the backlit first then press the button again for corres...

Страница 4: ...evice will follow the preset time periods and temperature to control heating system automatically Manual Mode Device will follow the manual setting temperature to control the heating system Vacation m...

Страница 5: ...In shutdown interface When the built in temperature sensor detect the temperature value 5 device will open anti freeze protection electric heating will be forced open and anti freeze protection icon...

Страница 6: ...ND_CLASS_MANUFACTURER_SPECIFI COMMAND_CLASS_TIME COMMAND_CLASS_TIME_PARAMETERS Note This device supports 4 kinds of modes in Z Wave Off mode Heating mode Manual Energy Saving heating mode Auto Away he...

Страница 7: ...N This limited warranty shall not apply if i the product was not used in accordance with any accompanying instructions or ii the product was not used for its intended function This limited warranty al...

Страница 8: ...5 9 5 16 16 P15 External temperature control switching OFF ON OFF Indoor temperature control ON ON OFF External sensor temperature control P16 External temperature display switching OFF ON OFF Indoor...

Отзывы: