www.mcohome.com User Manual
MCOHome Technology Co., Ltd
8
P07
Anti-freeze
temperature setting
5
℃(
41
℉)
0-30
℃(
32-86
℉)
P08
Protection
temperature
55
℃(
131
℉)
45-95
℃(
113-203
℉)
OFF
Indoor temperature
control
OFF
High temperature
control
P09
Power on state
OFF
OFF/OPN/PRU
= OFF electricity
power off
,
= OPN
electricity power
on
,
= PRU power
failure memory
P10
The time of
temperature change
2
0-99
P11
Temperature
calibration
0.0
℃
(00
℉
)
-9.5-9.5
℃(
-16-16
℉)
P12
Sound level
3
OF/0-9
P13
Backlit level
2
1-8/NO/OFF
P14
External temperature
0.0
℃
(00
℉
)
-9.5-9.5
℃(
-16-16
℉)
P15
External temperature
control switching
OFF
ON/OFF
Indoor temperature
control
ON
ON/OFF
External sensor
temperature control
P16
External temperature
display switching
OFF
ON/OFF
Indoor temperature
display
ON
ON/OFF
External temperature
display
P17
Temp. format
OC
OC/OF
=OC
,
Celsius
;
=OF
,
Fahrenheit
(
After modify
settings, to restore
the factory settings.
)
P18
Restore factory
setting
Display: 53
Password: 55
00-99
Change 53 to 55,
and press S3 to
confirm
*
After power failure:
0 indicates device will be in shutdown state (“OFF”) when power on again;
1 indicates device will be in working interface when power on again;
2 (default) indicates device will stay the status before power failure when power on again.