background image

 

 

12

reporting 

Temperature Difference 

Setting 

Unit: 0.1℃ 

Default: 5 

5*0.1℃=0.5℃ 

3-1000 

Timed Report Intervals 

Based on 1s unit, it is 

recommended to set it above 30s. 

 

30 

10-32768 

FF 

Factory Setting 

85: Restore factory setting(write 

only) 

 

85

 

 
                                                                 

1-year Limited Warranty                                                                                 

 

We warrant this product to be free from defects in material and workmanship under normal and proper use for one 

year from purchase date of the original purchaser. We will, at its option, either repair or replace any part of its products 

that  prove  defective  by  reason  of  improper  workmanship  or  materials.  THIS  LIMITED  WARRANTY  DOES  NOT 

COVER ANY DAMAGE TO THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, 

ABUSE, MISUSE, NATURAL DISASTER, INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY, ABNORMAL 

MECHANICAL OR ENVIRONMENTAL CONDITIONS, OR ANY UNAUTHORIZED DISASSEMBLY, REPAIR OR 

MODIFICATION.  This  limited  warranty  shall  not  apply  if:  (i)  the  product  was  not  used  in  accordance  with  any 

accompanying instructions, or (ii) the product was not used for its intended function. This limited warranty also does not 

apply to any product on which the original identification information has been altered, obliterated or removed, that has 

not been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary to Country 

and other applicable export regulations.

 

 

Содержание MH-F500

Страница 1: ...c heating water heating heat pump etc 8 types control systems 4 3 LCM display touch screen operation interaction Simpler way to connect wires without screw driver 7days 4 time periods scheduling Set t...

Страница 2: ...reach of children and animals Do not expose the device to moisture water or other liquids Do not place liquids near or on the device Do not attempt to disassemble repair or modify the device yourself...

Страница 3: ...n Instruction REQUIRED 24VAC POWER C WIRE Set system status 3 Wires Connection Instruction WIRE Display Functions Settings Set system status Wires Connection Instruction Display Functions Settings Set...

Страница 4: ...pper level setting interface without storing the changes Please check the following figures Set working mode The device provides two modes for the users Scheduling Hold Press Menu Next until the displ...

Страница 5: ...ress Done A node ID can always inform us whether the device is in the network or not Set schedule provides 4 times periods each day 7days for both heating and cooling status times SCHEDUL SET Edit Pre...

Страница 6: ...0 28 82 HEAT Mode 6 00 25 5 78 8 00 29 5 85 18 00 25 5 78 22 00 28 82 User Setup Press Menu Next press 4times USER SETUP Edit Temperature Scale TEMP SCALE Press to change between and Schedule for HEAT...

Страница 7: ...erence Press deleted the value Range 0 5 2 to set the brightness of the screen 0 Only display current indoor temperature in half brightness 1 Display all contents in half brightness 2 Display all cont...

Страница 8: ...ol O B Change over logic 8 to set the value OFF 5s 15s 30s OFF the fan not delay 5s the fan will delay 5s 15s the fan will delay 15s 30s the fan will delay 30s Setup Press Menu Next press 5times FACTO...

Страница 9: ...the outdoor temperature is extremely low so as to protect the outdoor unit CHANGE OVER When change over is ON the device will start heating or cooling automatically according to the desired temp When...

Страница 10: ...ice supports S2 function 2 Z WAVE supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION COMM...

Страница 11: ...value set by parameter 4 COMMAND_CLASS_THERMOSTAT_MODE_V2 THERMOSTAT_MODE_REPORT Thermostat mode changes COMMAND_CLASS_THERMOSTAT_OPERATING_STATE THERMOSTAT_OPERATING_STATE_REPORT Thermostat status c...

Страница 12: ...LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION ACCIDENT ABUSE MISUSE NATURAL DISASTER INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY ABNORMAL MECHANIC...

Отзывы: