background image

 

www.mcohome.com                                    User Manual

 

MCOHome Technology Co., Ltd 

4

 

0x0E and set value

0; 

15, 

Humidity IntervalReport

 Timer set value: 0x0F 

and set value

0; 

16, 

VOC  IntervalReport

  Timer  set  value:  0x10  and 

set value

0; 

17, 

Illumination  IntervalReport

  Timer  set  value: 

0x11 and set value

0; 

18, 

Noise IntervalReport

 Timer set value: 0x12 and 

set value

0; 

COMMAND_CLASS

_DEVICE_RESET_L

OCALLY, 

DEVICE_RESET_LO

CALLY_NOTIFICAT

ION 

Factory setting restored 

 
Command Class supported by the device: 

( Supports S2 unauthenticated level) 

 

COMMAND_CLASS_VERSION,                 

 

 

 

COMMAND_CLASS_MANUFACTURER_SPECIFIC,                       

 

COMMAND_CLASS_DEVICE_RESET_LOCALLY,                           

 

COMMAND_CLASS_POWERLEVEL,                                     

 

COMMAND_CLASS_ASSOCIATION,   
COMMAND_CLASS_ASSOCIATION_GRP_INFO,                                               

 

COMMAND_CLASS_CONFIGURATION, 
COMMAND_CLASS_SENSOR_MULTILEVEL

 

 

COMMAND_CLASS_FIRMWARE_UPDATE_MD                 

Command Class supported by the device:

 (Not supports S2) 

COMMAND_CLASS_ZWAVEPLUS_INFO,                                     
COMMAND_CLASS_TRANSPORT_SERVICE_V2,                                                           
COMMAND_CLASS_SECURITY_2,                                               
COMMAND_CLASS_SUPERVISION 
 

Restore Factory Setting 

1, Press & hold F1 to enter Z-Wave setting interface, then press & hold F1 again to enter parameters 
setting interface; 
2, Press & hold F2 to enter setting interface and select “default”; 
3, Click F2 3 times and displays “OFF”-->“ON”-->“OK”-->“OFF”, factory setting is restored. 
 

Data Calibration 

Hold  F1  to  choose  interface  for  data  calibration.  Then  hold  F2  to  switch  among  the  sensors. 

Choose  one  and  click  F2,  F1  to  change  the  data.  After  finished,  hold  F1  can  return  data  detecting 
interface. 

 
 

Содержание A8-9

Страница 1: ...82mm Housing Tempered glass PC Alloy Installation Wall mounted Vertical Safety Information To protect yourself and others from danger and to protect the device from damage please read the safety info...

Страница 2: ...e the adaptor Step 3 Put the device back onto the steel frame it will attach with the frame firmly by built in magnets Step 4 Check the installation and power the device is ready for work Operation Po...

Страница 3: ...previous reported value 0x03 set value set value 0 4 Humidity Thevalue difference between current value and previous reported value 0x04 set value set value 0 5 VOC The value difference between curren...

Страница 4: ...EVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_FIRMWARE_UPDATE_MD Command Class supported by the device Not...

Страница 5: ...hen change n 0 5 0 0 127 0x04 Humidity_Delta_Level 1 0 Turn off report 1 Report when change n 0 0 127 0x05 VOC_Delta_Level 1 0 Turn off report 1 127 5ppb Reportchange 0 0 127 0x06 Lux_Delta_Level 2 0...

Страница 6: ...x12 dB_Timer 2 0 Turn off report 35 Report every n 1s interval 300 0 35 32767 0x2F Temp unit 1 0 1 0 0 1 0x32 T_OffSet 1 0 127 n 100 10 10 2 7 128 1 156 n 10 2 8 15 5 100 128 127 0x33 RH_OffSet 1 n 20...

Страница 7: ...INSTALLATION ACCIDENT ABUSE MISUSE NATURAL DISASTER INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY ABNORMALMECHANICAL OR ENVIRONMENTAL CONDITIONS OR ANY UNAUTHORIZED DISASSEMBLY REPAIR OR MODIFICATION Th...

Отзывы: