                                                          Installation &Wiring     

Location: 

Device is suggested to be installed indoor, a place with around 1.5m height above the floor where 

represents the average CO2 concentration. It should be away from direct sunlight, any cover, or any 
heat source, to avoid false signal for temperature control. 

 

 

 

Notice! 

1. Device must be wall-mounted vertically. Do not lay it flat 

or upside down while working. 

2.  Do  not  mounted  it  in  a  wind  gap,  or  cover  its  bottom, 

which may affect the detected data. 

 

Step 1:

Remove the steel frame from the backside of the device, and then fix it onto the installation 

box with 2 screws.   

Step 2:

Wire the adaptor. 

Step 3:

Put the device back onto the steel frame, it will attach with the frame firmly by built-in 

magnets.     

Step 4:

Check the installation and power, the device is ready for work. 

 

                                                                Operation         

 
Power on/ power off

 

Wire the adaptor and the device is powered on. It will display all detected information by the sensors. 
 

Display interface

 

Hold Key F1 can switch among the following 4 display interfaces: 
1. Data detecting: display all sensors’ data 
2. Network: Z-Wave Add/Remove 
3. Data calibration: to calibrate the detected data manually 
4. Local time setting 
 

Z-Wave Operation 

Note: A Security Enabled Z-Wave Controller must be used in order to fully utilize the product. 

 

Add &Remove Z-Wave network 

 

Activate  Add/Remove  mode  in  the  gateway.  When  device  is  powered  on,  hold  F1  to  choose 
interface for Add or Remove Z-Wave network. 

 

Click F2 five times until 

  turns blue. 

Содержание A8-9

Страница 1: ...82mm Housing Tempered glass PC Alloy Installation Wall mounted Vertical Safety Information To protect yourself and others from danger and to protect the device from damage please read the safety info...

Страница 2: ...e the adaptor Step 3 Put the device back onto the steel frame it will attach with the frame firmly by built in magnets Step 4 Check the installation and power the device is ready for work Operation Po...

Страница 3: ...previous reported value 0x03 set value set value 0 4 Humidity Thevalue difference between current value and previous reported value 0x04 set value set value 0 5 VOC The value difference between curren...

Страница 4: ...EVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_FIRMWARE_UPDATE_MD Command Class supported by the device Not...

Страница 5: ...hen change n 0 5 0 0 127 0x04 Humidity_Delta_Level 1 0 Turn off report 1 Report when change n 0 0 127 0x05 VOC_Delta_Level 1 0 Turn off report 1 127 5ppb Reportchange 0 0 127 0x06 Lux_Delta_Level 2 0...

Страница 6: ...x12 dB_Timer 2 0 Turn off report 35 Report every n 1s interval 300 0 35 32767 0x2F Temp unit 1 0 1 0 0 1 0x32 T_OffSet 1 0 127 n 100 10 10 2 7 128 1 156 n 10 2 8 15 5 100 128 127 0x33 RH_OffSet 1 n 20...

Страница 7: ...INSTALLATION ACCIDENT ABUSE MISUSE NATURAL DISASTER INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY ABNORMALMECHANICAL OR ENVIRONMENTAL CONDITIONS OR ANY UNAUTHORIZED DISASSEMBLY REPAIR OR MODIFICATION Th...

Отзывы: