background image

 

www.mcohome.com                                    User Manual

 

MCOHome Technology Co., Ltd 

1

 

 

9 in 1 Multi-Sensor

 

A8-9 

 

MCOHome A8-9 is a Z-Wave enabled multiple environmental monitoring sensors, with 3.5 inch TFT 
clear  display  and  compliant  to  Z-Wave  Plus  standard.  It  is  built  in  with 

Temperature,  Humidity, 

PM2.5, CO2, VOC, PIR, illumination, Noise, Smoke

 sensors. Device can be added into any Z-Wave 

network, and is compatible with any other Z-Wave certified devices.

 

 

 

Temperature: 0~50℃ 

 

Humidity: 0%RH~99%RH 

 

PM2.5: 0~500ug/m3 

 

CO2: 0~5000ppm 

 

VOC: 0-64000ppb   

 

PIR: 0 or 1 Detection angle up to 120° 

 

Illumination: 0~40000Lux                                     

 

Noise: 30dB~100dB 

 

Smoke: 0 or 1 
 

Specification 

 

Power Supply: DC12V 

 

Self-dissipation:<3W 

 

Work  environment:-20~+60

  <99%RH   

(Non-condensation) 

 

Dimension: 110* 110*32mm 

 

Hole Pitch: 60mm or 82mm 

 

Housing: Tempered glass+ PC Alloy 

 

Installation: Wall-mounted (Vertical) 

 

Safety Information

 

To protect yourself and others  from  danger  and to  protect the device from damage, please read the 
safety information before using it. 

Important!   

 

A  qualified  electrician  with  the  understanding  of  wiring  diagrams  and  knowledge  of  electrical 
safety should complete installation following the instructions. 

 

Before  installation,  please  confirm  the  real  voltage  complying  with  the  device’s  specification. 
Cut off any power supply to secure the safety of people and device.   

 

During  installation,  protect  the  device  from  any  physical  damage  by  dropping  or  bumping.  If 
happens, please contact the supplier for maintenance. 

 

Keep the device away from acid-base and other corrosive solids, liquids, gases, to avoid damage. 

 

Avoid overexertion during operation, to protect device from mechanical damage. 

 

Read all instructions and documentation and save for future reference. 

 
 

Содержание A8-9

Страница 1: ...82mm Housing Tempered glass PC Alloy Installation Wall mounted Vertical Safety Information To protect yourself and others from danger and to protect the device from damage please read the safety info...

Страница 2: ...e the adaptor Step 3 Put the device back onto the steel frame it will attach with the frame firmly by built in magnets Step 4 Check the installation and power the device is ready for work Operation Po...

Страница 3: ...previous reported value 0x03 set value set value 0 4 Humidity Thevalue difference between current value and previous reported value 0x04 set value set value 0 5 VOC The value difference between curren...

Страница 4: ...EVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_FIRMWARE_UPDATE_MD Command Class supported by the device Not...

Страница 5: ...hen change n 0 5 0 0 127 0x04 Humidity_Delta_Level 1 0 Turn off report 1 Report when change n 0 0 127 0x05 VOC_Delta_Level 1 0 Turn off report 1 127 5ppb Reportchange 0 0 127 0x06 Lux_Delta_Level 2 0...

Страница 6: ...x12 dB_Timer 2 0 Turn off report 35 Report every n 1s interval 300 0 35 32767 0x2F Temp unit 1 0 1 0 0 1 0x32 T_OffSet 1 0 127 n 100 10 10 2 7 128 1 156 n 10 2 8 15 5 100 128 127 0x33 RH_OffSet 1 n 20...

Страница 7: ...INSTALLATION ACCIDENT ABUSE MISUSE NATURAL DISASTER INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY ABNORMALMECHANICAL OR ENVIRONMENTAL CONDITIONS OR ANY UNAUTHORIZED DISASSEMBLY REPAIR OR MODIFICATION Th...

Отзывы: