background image

 10

Front Panel Controls, Push-Buttons, Switches

and Displays

The INPUT switch

selects any one of the

four DIGITAL IN-

PUTS or the ANA-

LOG INPUT

The CHANNEL STATUS LED display indi-

cates which channels are active, depending on

the incoming signal; L (Left Front), C (Cen-

ter), R (Right Front), LFE (Low Frequency

Effects), LS (Left Surround), S (Pro Logic

Surround), R (Right Surround)

The appropriate nomen-

clature turns on to indi-

cate which Dolby or

DTS mode is active

The DELAY/VOLUME dis-

play indicates three types of

information; Volume Level,

System Calibration, and Time

Delay

The VOLUME control

is used for four differ-

ent operations; level

match, volume level,

channel time delay and

system level calibration

The IR (Infra Red) sensor

accepts IR signals di-

rectly from an HR39/

HR130 Remote Control

The SURROUND push-

button switches between

internal Dolby Surround

Decoding and Stereo

Front Panel Controls, Push-Buttons,

Switches and Displays

Press the SYS CAL,

(System Calibration)

push-button to activate

the internal test signal

generator for surround

channel level calibration

The LATE NIGHT

push-button turns the

volume compression

circuit ON and OFF

The Re-EQ+TM push-

button activates the RE-

EQualization filter and

Timbre Match, which

compensates for the

differences in room

acoustics between the

movie theater and a

home theater room

The POWER

switch turns all

power completely

ON or OFF.

Press the CNTR (Center)

DELAY push-button to

temporarily activate the

center channel time delay

adjusting process

Press the SURR (SUR-

ROUND) push-button to

temporarily activate the

surround channel time

delay adjusting process

The VOLUME push-

button activates the

various volume control

functions

The STANDBY/ON

push-button turns the

MSD4 on and off, and

can reset all the MSD4

microprocessors

www.freeservicemanuals.info

5/10/2017

Digitized in Heiloo Netherland

Содержание MSD4

Страница 1: ...registered trademarks of Dolby Laboratories and manufactured under license from Dolby Laboratories DTS digital sur round and coherent acoustics are registered trademark of DTS Technology LLC and manu...

Страница 2: ...al s for any component s connected to the MSD4 Surround Decoder Please Take A Moment The serial number purchase date and McIntosh dealer name are important to you for possible insurance claim or futur...

Страница 3: ...hrough the ventilation openings 10 Locate the equipment away from heat sources such as radiators heat registers stoves or other appliance in cluding amplifiers that produce heat 11 Mount the equipment...

Страница 4: ...in a risk of fire or electric shock Care of Equipment 18 Clean the instrument by dusting with a dry cloth Un plug this equipment from the wall outlet and clean the panel with a cloth moistened with a...

Страница 5: ...tem channels for surround level calibration The levels can be adjusted plus or minus 12dB Re EQ TM Re Equalization filter and Timbre Matching modify the sound tracks created for a large theater so the...

Страница 6: ...cm above the unit so airflow is not obstructed Allow 17 1 2 inches 44 5cm depth behind the mounting panel which includes clearance for connec tors Allow 1 1 8 inches 2 9cm in front of the mounting pan...

Страница 7: ...hen the MSD4 is being used in a system with a C39 or MX130 the POWER CONTROL IN receives turn on and off signals from the McIn tosh Control Center The POWER CONTROL OUT jack sends a turn on and off si...

Страница 8: ...e AC 3 RF input on the MSD4 b Connect either the MLD7020 Optical or Coaxial Digital Output to the matching MSD4 Digital Input 2 DVD Digital Versatile Disc Player a Connect the DVD digital output eithe...

Страница 9: ...he MVS 3 Control Center Audio Outputs to the MSD4 Analog Input Connect to a Digital Signal Source 1 McIntosh MLD7020 Laser Video Disc player a Connect the MLD7020 RF OUT to the AC 3 RF input on the MS...

Страница 10: ...ween internal Dolby Surround Decoding and Stereo Front Panel Controls Push Buttons Switches and Displays Press the SYS CAL System Calibration push button to activate the internal test signal generator...

Страница 11: ...enter speaker is the same distance as the front speakers no calibration is necessary since the default factory setting is 0ms If the center speaker is closer than the front speakers you should adjust...

Страница 12: ...nter Channel 0 Surround Channels 5 Selecting inputs with the Remote Control results in the MSD4 input selection automatically tracking with the Con trol Center input If Inputs are selected manually by...

Страница 13: ...30 con t lower from the front left and right speakers and redirect them to the Subwoofer speaker Center Speaker None Small Large When the center speaker covers the full frequency range down to 20Hz se...

Страница 14: ...any adjustments are performed NOTE The front panel CHANNEL STATUS LED s will light to indicate which channel is reproducing the test signal 4 While seated in the listening area note the volume lev el...

Страница 15: ...sh button is pressed the test signal will switch to the Left Front channel and will stay in that channel until the SYS CAL push button is pressed again followed by the Center Right Front Right Surroun...

Страница 16: ...S will turn on in accordance to the channels that are present on the DTS sound track If the signal source contains only a Dolby Pro Logic sound track the MSD4 switches to Pro Logic mode The front pane...

Страница 17: ...SL 6 HT 2 or SL 1 HT 3 HT 4 use the following settings Set FRONT to SMALL Set CENTER to SMALL Set SURR to SMALL Set SUBWOOF to ON Set SUBWOOF to ON Volume Control Set the VOLUME control to the desired...

Страница 18: ...Output Voltage 8VRMS Total Harmonic Distortion 0 005 at all outputs Sensitivity Analog Input 500mV for 2 0V output 100mV IHF Signal To Noise Ratio All Outputs Greater than 90dB un weighted Greater tha...

Страница 19: ...in good serviceable condition If a shipping carton or any of the interior part s are needed please call or write Customer Service Department of McIntosh Labo ratory Please see the Part List for the co...

Страница 20: ...McIntosh Part No 040594 McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www freeservicemanuals info 5 10 2017 Digitized in Heiloo Netherland...