background image

15

Calibration Channel

Default Setting

New Setting

Left Front

0

Center Front

0

Right Front

0

Right Surround

0

Left Surround

0

Subwoofer

0

bers, and if decreased shows minus numbers. Calibra-

tion levels can be adjusted over a range of plus or mi-

nus 12dB.

6. When the test signal switches to succeeding channels,

repeat the level calibration process until the test signal

volume levels of all the channels are the same.

7. The calibration channel cycling mode can be repeated

as often as necessary until you are satisfied that the

volume levels of the test signal are the same from all

channels.

8. Exit the System Calibration mode by pressing the SYS

CAL push-button a second time.

NOTE: All System Level Calibrations are retained in

permanent memory and will change only if calibration

is performed again. The factory default setting for the

volume control is 75.

Manual

System

Calibration

1. Set the

rear panel

SYSTEM

CALI-

BRATE

switch to

MAN.

2. Adjust the

MSD4

volume

control until the display reads at least 70, an initial ref-

erence setting to ensure that the test signals will be ad-

equately loud to perform the level calibration.

3. Press the SYS CAL push-button once to start Manual

System Calibration. The first time the SYS CAL push-

button is pressed, the test signal will switch to the Left

Front channel and will stay in that channel until the

SYS CAL push-button is pressed again, followed by

the Center, Right Front, Right Surround, Left Surround

and

Subwoofer. The MSD4 DELAY/VOLUME display

will read “0” for each channel before any adjustments

are performed.

NOTE: The front panel CHANNEL STATUS LED’s will light to

indicate which channel is reproducing the test signal. A

more convenient method of manually switching the test

signal is to use the SP push-button on the optional

HR34/HR39/HR130 Remote Control which performs the

same functions as the SYS CAL push-button.

4. While seated in the listening area, note the volume

levels of the test signal from each of the channels. If

you determine that the test signal volume is louder or

softer in any of the channels, the levels should be

adjusted so you hear essentially the same test signal

volume from all of the channels. The left front channel

volume level can serve as a reference.

5. Exit the Manual System Calibration mode by pressing

the SYS CAL push-button after calibrating the

Subwoofer channel.

NOTE: All System Level Calibrations are retained in permanent

memory and will change only if calibration is

performed again. The following table may be used to

record your Delay Calibrations Settings.

System Level Calibration

con’t

Figure 5

www.freeservicemanuals.info

5/10/2017

Digitized in Heiloo Netherland

Содержание MSD4

Страница 1: ...registered trademarks of Dolby Laboratories and manufactured under license from Dolby Laboratories DTS digital sur round and coherent acoustics are registered trademark of DTS Technology LLC and manu...

Страница 2: ...al s for any component s connected to the MSD4 Surround Decoder Please Take A Moment The serial number purchase date and McIntosh dealer name are important to you for possible insurance claim or futur...

Страница 3: ...hrough the ventilation openings 10 Locate the equipment away from heat sources such as radiators heat registers stoves or other appliance in cluding amplifiers that produce heat 11 Mount the equipment...

Страница 4: ...in a risk of fire or electric shock Care of Equipment 18 Clean the instrument by dusting with a dry cloth Un plug this equipment from the wall outlet and clean the panel with a cloth moistened with a...

Страница 5: ...tem channels for surround level calibration The levels can be adjusted plus or minus 12dB Re EQ TM Re Equalization filter and Timbre Matching modify the sound tracks created for a large theater so the...

Страница 6: ...cm above the unit so airflow is not obstructed Allow 17 1 2 inches 44 5cm depth behind the mounting panel which includes clearance for connec tors Allow 1 1 8 inches 2 9cm in front of the mounting pan...

Страница 7: ...hen the MSD4 is being used in a system with a C39 or MX130 the POWER CONTROL IN receives turn on and off signals from the McIn tosh Control Center The POWER CONTROL OUT jack sends a turn on and off si...

Страница 8: ...e AC 3 RF input on the MSD4 b Connect either the MLD7020 Optical or Coaxial Digital Output to the matching MSD4 Digital Input 2 DVD Digital Versatile Disc Player a Connect the DVD digital output eithe...

Страница 9: ...he MVS 3 Control Center Audio Outputs to the MSD4 Analog Input Connect to a Digital Signal Source 1 McIntosh MLD7020 Laser Video Disc player a Connect the MLD7020 RF OUT to the AC 3 RF input on the MS...

Страница 10: ...ween internal Dolby Surround Decoding and Stereo Front Panel Controls Push Buttons Switches and Displays Press the SYS CAL System Calibration push button to activate the internal test signal generator...

Страница 11: ...enter speaker is the same distance as the front speakers no calibration is necessary since the default factory setting is 0ms If the center speaker is closer than the front speakers you should adjust...

Страница 12: ...nter Channel 0 Surround Channels 5 Selecting inputs with the Remote Control results in the MSD4 input selection automatically tracking with the Con trol Center input If Inputs are selected manually by...

Страница 13: ...30 con t lower from the front left and right speakers and redirect them to the Subwoofer speaker Center Speaker None Small Large When the center speaker covers the full frequency range down to 20Hz se...

Страница 14: ...any adjustments are performed NOTE The front panel CHANNEL STATUS LED s will light to indicate which channel is reproducing the test signal 4 While seated in the listening area note the volume lev el...

Страница 15: ...sh button is pressed the test signal will switch to the Left Front channel and will stay in that channel until the SYS CAL push button is pressed again followed by the Center Right Front Right Surroun...

Страница 16: ...S will turn on in accordance to the channels that are present on the DTS sound track If the signal source contains only a Dolby Pro Logic sound track the MSD4 switches to Pro Logic mode The front pane...

Страница 17: ...SL 6 HT 2 or SL 1 HT 3 HT 4 use the following settings Set FRONT to SMALL Set CENTER to SMALL Set SURR to SMALL Set SUBWOOF to ON Set SUBWOOF to ON Volume Control Set the VOLUME control to the desired...