Test for Slippage
Bring the fitting against the main under full fusion pressure
to insure that no slippage or movement of the main or fitting
occurs.
TX00462-9-14-94
Clamp Fitting
Position the fitting, and bolster if required, loosely in the movable
jaw(s). Move the carriage to the right to properly position the
fitting on the main. Tighten the clamp knobs.
Be sure to allow enough travel for the melt pattern and fusion to
occur (3/4" min.).
TX00461-9-15-94
Special Operations
- Saddle Fusion Procedure
PH00399-9-21-94
5 - 3
PH00390-9-21-94
Clean Surfaces
Use 50 or 60 grit utility cloth to clean and rough the main to
expose fresh material.
Rough the base of the fitting unless the manufacturer specifies
otherwise.
Surface must be free of water and oil.
TX01879-11-10-00