Operation
3 - 2
Load Pipe Into Machine
Clean the inside and outside of pipe ends that are to be fused.
Open the upper jaws and insert pipe in each pair of jaws with
applicable inserts installed. Let the ends of the pipe protrude
about 3/4" past the face of the jaws. Close upper jaws but do
not clamp tight.
TX04142-8-3-10
PH
04
26
5-
7-
20
-10
Insert Facer
Place the end opposite the handle onto the far guide rod, then
lower the facer handle end down onto the near guide rod and
latch.
TX01851-7-25-00
PH
04
26
6-
7-
20
-10
Positioning Pipe in Machine
Position the facer on the guide rods and lock into position. Using lever
handle, bring pipe ends together against the facer, watching the gap
between the facer stops and the pipe clamping jaws. Leave enough
gap
so that proper face-off will be achieved when the facer stops are
bottomed out against the clamps. Tighten the pipe clamp knobs by
hand until firm resistance is felt. Do not over-tighten.
NOTICE:
Thoroughly clean all dirt and debris from pipe ends before
facing.
TX00839-1-5-96
PH
04
26
7-
7-
20
-10
Face the Pipe
The electric facer should be started before the pipe is pushed into
contact with the blades. Continue facing until the facer stops are against
the jaws then turn off the facer while continuing to hold pressure closed
on the lever until the facer stops completely.
Reverse force to the lever handle to move the pipe ends away from the
facer. Unlatch and remove the facer taking care not to touch the pipe
ends. Remove shavings from pipe ends and machine. Do not touch
faced pipe ends as this may contaminate them.
If after facing any imperfections are visible on the ends of the pipe move
the pipe inward and reface.
Any time clamp knobs are tightened pipe ends should be refaced.