Maintenance
Facer and Blades
The facers are packed with a high temperature grease at
assembly. The facer does not require repacking of grease.
Inspect the facer blades for damage and sharpness. If dullness or
damage appears on one section of the blade, installing the blade
on the opposite side of the blade holder will normally position a
sharp edge in the facing zone. Chipped or dull blades must be
replaced.
NOTICE:
Never extend the blade beyond the inner or outer
circumference of the facer.
TX02473-3-29-05
Facer Guides
To minimize friction on the guide rods, keep the guides clean
using a clean dry cloth to wipe away debris.
TX02480-3-30-05
PH
04
281-
7-
20
-10
5 - 4
Heater Indicator Light
The heater has a green indicator light which will flash on and off.
This indicates that the controller is operating normally. If the green
indicator is not flashing then the controller may not be operating
properly. If this occurs, disconnect power and have the heater
repaired by an McElroy Authorized Service Center.
The heater has a red indicator light on the handle at the bottom
of the temperature scale. When the heater is plugged in and
preheating the red light glows steadily until the set temperature
is reached. The red light then goes off and on as the heater
maintains temperature.
If the heater is not operating properly, the control will attempt to turn
the heater off and the red indicator light will flash rapidly. If this
occurs, disconnect the power and take it to a McElroy Authorized
Service Center for repair.