3 - 5
Operation
Setup to Log a Joint (cont’d)
Measure the heater temperature using a user provided
pyrometer.
Press the
Up/Down
keys to change heater temperature reading
based on the temperature measured.
When the reading is below the specification lower limit,
the background turns blue indicating temperature too low.
When the reading is above the specification upper limit, the
background turns red indicating temperature too high.
Tap
Next >>
to get ready to log a joint.
Make sure pipe ends are properly faced and
heater is securely placed in the fusion machine
between two pipe ends.
Press the
Right Soft Key
then
Enter
or tap
Log...
and then
Start
to begin logging then close the
carriage to heat pipe.
If necessary, press
<< Back
to review or change settings on previous screens
or tap
Cancel
to go back to the main DataLogger screen.
While logging a joint, the number of data points logged is
displayed, along with the elapsed time, the current pressure
reading, the various pressures, times, bead size, and open/
close time.
A stop watch at the lower left corner can be used to time the
various fusion cycles. Pressing the
Left Soft Key
or tapping
Reset
SW
resets the stopwatch count.
At the end of the fusion, press the
Right Soft Key
then
Enter
or tap
Stop
then
Yes
to stop logging.
PH04619-2-13-11
PH04984-11-14-13
PH04982-11-14-13