background image

McCall

 

Serial Number .......................................................................3

Receiving And Inspecting The Equipment ............................3

Model Numbers ....................................................................4

Introduction ..........................................................................5

Specifications .................................................................... 6-7

Installation ........................................................................ 8-9

Electronic Temperature Control Operation ..........................10

Heated Cabinet Operation ...................................................11

Maintenance .................................................................. 12-13

Wiring Diagrams ........................................................... 14-20

Compressor Diagrams ........................................................21

Replacement Parts ........................................................ 22-24

Standard Labor Guidelines ..................................................25

Standard One Year Warranty ...............................................26

Additional Three Year Warranty ..........................................27

The  serial  number  is  on  the  identification  plate  that  also 

includes  the  model  number.  A  typical  identification  plate 

is  shown  below.  On  refrigeration  and  freezer  unit  the 

identification plate is located inside the right most door near 

the top front corner of the right interior wall. On heated units, 

the  identification  plate  is  located  in  the  shroud  area  on  the 

right side panel.

Always  have  the  serial  number  of  your  unit  available 

when  calling  for  parts  or  service.  A  complete  list  of 

authorized  McCall  parts  depots  can  be  found  at  www.

mccallrefrigeration.com.

©2010 McCall.  All rights reserved.  Reproduction without written permission 
is prohibited.

Contents

Serial Number Location

Even though most equipment is shipped crated, care should be 

taken during unloading so the equipment is not damaged while 

being moved into the building.

1.  Visually  inspect  the  exterior  of  the  package  an  skid  or  

container.  Any damage should be noted and reported to the 

delivering carrier immediately.

2.  If damaged, open and inspect the contents with the carrier.
3.  In  the  event  that  the  exterior  is  not  damaged,  yet  upon 

opening, there is concealed damage to the equipment notify 

the carrier.  Notification should be made verbally as well as 

in written form.

4.  Request  an  inspection  of  the  concealed  equipment.  

This  should  be  done  within  10  days  from  receipt  of  the 

equipment.

5.  Check the lower portion of the unit to be sure legs or casters 

are not bent.

6.  Also  open  the  compressor  compartment  housing  and 

visually inspect the refrigeration package.  Be sure lines are 

secure and base is still intact.

7.  Freight  carriers  can  supply  the  necessary  forms  upon 

request.

8.  Retain all crating material until an inspection has been made 

or waived.

Uncrating the Equipment

First cut and remove the banding from around the crate.  Remove 

the front of the crate material, use of some tools will be required.  

If the unit is on legs remove the top of the crate as well and lift 

the unit off the skid.  If the unit is on casters it can be "rolled" off 

the skid.

Receiving And Inspecting The Equipment

 

      

       

Covington, Tennessee 

 

  Model:   MCCR1-S            Serial #: 0801152000599    

  Elec.Req.: 115V   60Hz    1Ph             Ampacity:  6.8 

 

                                      System 1            System 2 

   Refrigerant Type:        R404A 

   Refrigerant Amount:   12.5ozs.  

   Design Pressures:        

 

                High Side:      450  

                 Low Side:      150  

 

 

 

 

         

For Parts or Service Please Call:

 

                                          1-800-733-8829 

 

                                          

              

 

 

 

Содержание MCCDRL2-G

Страница 1: ...TRUCTIONS Series I Reach Ins with Aluminum Interior Service Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of dam...

Страница 2: ...OTHER APPLIANCE UNLESSALLCOVERANDACCESSPANELSAREINPLACEANDPROPERLYSECURED DO NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPT...

Страница 3: ...terior of the package an skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that...

Страница 4: ...CC McCall Reach In R Refrigerator F Freezer H Heated D Dual Temp None Reach in PT Pass Thru RL Refrigerator Left TR Top Refrigerator 1 1 Section 2 2 Section 3 3 Section S Solid Full SH Solid Half SLG...

Страница 5: ...tic expansion valve System is controlled using an electronic temperature control which provides improved pull downtimes reducingcompressorcyclingandlongercompressor lifewithlowerenergyconsumption Cont...

Страница 6: ...Amps Storage Capacity Ft3 Shelf Capacity Ft2 No Of Shelves H P BTU HR R 404A Charge Oz Shipping Weight NEMA Plug Energy KWH MCCDTR1 SH Refrigerator 115 14 0 11 52 4 23 2 1 5 1543 10 525lbs 238kg 5 20P...

Страница 7: ...15P 4 58 MCCRPT2 S SH 115 16 0 55 42 27 54 6 1 2 5465 24 700lbs 318kg 5 20P 5 96 MCCRPT2 G GH 115 16 0 55 42 27 54 6 1 2 5465 24 700lbs 318kg 5 20P 8 16 Reach In Hot Food Cabinets Hinged Doors Standa...

Страница 8: ...lift it up and ease it out of the hinge brackets Leg Caster Utility Base Installation Some cabinets may weigh over 1000 pounds 450 kg Use a lifting device capable of supporting the unit when removing...

Страница 9: ...means to satisfy the authority having jurisdiction The power cords supplied with this equipment are three pronged plugs and must be connected to a three pronged wall outlet for proper grounding Do not...

Страница 10: ...rstheevaporatortemperature and will turn off the compressor and condenser fan motor when needed to allow accumulated frost on the evaporator to clear During this defrost cycle the digital temperature...

Страница 11: ...aise the shroud to access the controls Set the Main POWER ON OFF switch to the ON position Adjust the electronic thermostat to the desired tempera ture Allow unit to warm up before use 1 2 3 4 5 The u...

Страница 12: ...begin to breakdown the steel and begin to form discoloration or rust Proper cleaning of stainless steel requires soft cloths or plastic scouring pads NEVER USE STEEL PADS WIRE BRUSHES OR SCRAPERS Cle...

Страница 13: ...rage area restricting the airflow and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature Preventing blower coil corrosion To help...

Страница 14: ...8 34 24 2 9 30 54 7 2 0 5 02 33 2 2 4 23 4 3 42 2 5 4 2 9 02 33 2 4 3 4 8 42 2 9 3 6 2 5 42 4 0 2 452 7 53 30 9 34 24 7 3 2 7 2 5 6 0 2 4 2 53 4 2 6 0 3 3 2 4 2 6 0 3 3 2 7 7 7 7 34 24 2 5 4 2 02 4 4...

Страница 15: ...15 McCall Refrigerator Wiring Diagrams MCCR2 Solid Doors MCCR2 MCCR2 SL Glass Doors...

Страница 16: ...16 McCall Series I Reach In Manual Refrigerator Wiring Diagrams MCCRPT2 MCCR3 Solid Doors MCCRPT2 MCCR3 Glass Doors...

Страница 17: ...9 5 37 4 7 7 7 02 4 4 2 2 9 4 2 2 9 6 0 2 4 2 2 34 4 2 3 2 MCCF1 Solid Doors 30 9 3 2 2 34 4 2 6 0 2 4 2 2 2 6 4 3 0 4 2 8 5 53 3 2 9 3 6 2 37 4 4 2 2 9 02 33 2 2 9 42 4 0 2 452 30 9 53 6 0 3 3 2 3 3...

Страница 18: ...18 McCall Series I Reach In Manual Freezer Wiring Diagrams PDF created with pdfFactory trial version www pdffactory com MCCF2 Solid Doors MCCF2 MCCF3 Glass Doors...

Страница 19: ...19 McCall Freezer Wiring Diagrams MCCF3 Solid Doors MCCDTR1 Solid Doors Refrigerator Freezer Combination Wiring Diagram...

Страница 20: ...20 McCall Series I Reach In Manual MCCH1 MCCH2 MCCH3 Solid Glass Doors Heated Models Wiring Diagram...

Страница 21: ...mpressor Relay Overload Capacitor start Drier filter Motor fan condensor Switch Control switch Blade fan Motor fan evaporator Coil evaporator Coil condenser Blade fan condenser Guard fan condenser Com...

Страница 22: ...0019 Guard Fan Wire 2162716 Motor Fan 16W 115V CW 3516438 Relay Comp Ovld NF7CLX 2190154 Switch Rocker 20A 125V 3516570 Thermometer Digital 3516429 Valve Therm EXP W O MOP MCCRPT1 Glass Doors Part Num...

Страница 23: ...DR 2194953 Limit High Defrost 2162716 Motor Fan 16W 115V CW 2162715 Motor Fan Bay 3 4ST 2194959 Switch Rocker Snap in 3516570 Thermometer Digital MCCF2 Solid Doors Part Number Description 3516433 Blad...

Страница 24: ...6968 Cond Unit 1 5HP 404A REF 2194782KT Control REF Danfoss 2194536 Control Temp In 40D Out 2194046 Fan Delay Defrost Limit 3516173 Guard Plastic Fan 6 3978197 Guard Wire Evaporator 2194659 Heater 115...

Страница 25: ...our Is Allowed To Replace Thermostat Contactor Relay Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch Microproc...

Страница 26: ...ALLS WILL BE BILLED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition...

Страница 27: ...s Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigerat...

Страница 28: ...___ S N ____________________ Installation Date _____________ For a list of McCall s authorized parts depots visit our website at www mccallrefrigeration com 980 S Isabella Rd Mt Pleasant MI 48858 U S...

Отзывы: