background image

McCall

 

Additional Four Year Protection Plan

 

(for motor-compressor only)

In addition to the Standard One Year Warranty on the Motor-
Compressor contained in the above listed McCall product (the 
“Unit”), McCall also agrees to repair, or exchange with similar 
or interchangeable parts in design and capacity at McCall’s 
option, the defective Motor-Compressor contained in the Unit 
(the “Motor-Compressor), or any part thereof, for the Original 
Purchaser only, at any time during the four (4) years following 
the  initial  one  (1)  year  period  commencing  on  the  date  of 
installation for the Original Purchaser. 

Failure of the Original 

Purchaser to register the registration card containing the 
Original Purchasers name, address, date of installation, 
model number and serial number of the Unit containing 
the  Motor-Compressor  within  30  days  from  the  date  of 
installation shall void this warranty. 

This additional warranty 

is only available if the Motor-Compressor is inoperative due 
to defects in material or factory workmanship, as determined 
by  McCall  in  its  sole  judgment  and  discretion.  The  Original 
Purchaser  shall  be  responsible  for  returning  the  defective 
Motor-Compressor to McCall prepaid, F.O.B. at the address 
shown on the back cover of this manual.
The  term  “Original  Purchaser”  as  used  herein  means  that 
person, firm, association, or corporation for whom the Unit was 
originally installed.
The term “Motor-Compressor” as used herein does not include 
unit base, air or water cooled condenser, receiver, electrical 
accessories such as relay, capacitors, refrigerant controls, or 
condenser fan/motor assembly. This warranty does not cover 
labor  charges  incidental  to  the  replacement  of  parts.  This 
warranty  further  does  not  include  any  equipment  to  which 
said  condensing  unit  is  connected,  such  as  cooling  coils, 
temperature  controls  or  refrigerant  metering  devices.  This 
warranty shall be void if the Motor-Compressor, in McCall’s sole 
judgement, has been subjected to misuse, neglect, alteration or 
accident, operated contrary to the recommendations specified 
by the Unit manufacturer, repaired or altered by anyone other 
than McCall in any way so as, in McCall’s sole judgment, to 
affect its quality or efficiency or if the serial number has been 
altered, defaced or removed. This Warranty does not apply to 
a Motor-Compressor in any Unit that has been moved from 
the location where it was originally installed. The addition of 
methyl chloride to the condensing unit or refrigeration system 
shall void this warranty.

General Conditions

McCall  shall  not  be  liable  in  any  manner  for  any  default  or 
delay in performance hereunder caused by or resulting from 
any contingency beyond McCall’s control, including, but not 
limited to, war, governmental restrictions or restraints, strike, 
lockouts, injunctions, fire, flood, acts of nature, short or reduced 
supply of raw materials, or discontinuance of any part or the 
MotorCompressor by the unit manufacturer.
Replacement of a defective Motor-Compressor is limited to one 
(1) Motor-Compressor by us during the four (4) four period. 
McCall shall replace the Motor-Compressor at no charge.
This warranty does not give the Original Purchaser of the Motor-
Compressor  the  right  to  purchase  a  complete  replacement 
Motor-Compressor  of  the  same  make  or  of  another  make. 
It  further  does  not  permit  the  replacement  to  be  made  with 
a  Motor-Compressor  of  another  kind  unless  authorized  by 
McCall. In the event McCall authorizes the Original Purchaser 
to purchase a replacement Motor-Compressor locally, only the 
wholesale cost of the Motor-Compressor is refundable.

Expressly excluded from this warranty are damages resulting 

from spoilage of goods.

Except as provided in any applicable Standard One Year 
Limited Warranty or applicable Service Labor Contract, the 
foregoing is exclusive and in lieu of all other warranties, 
whether written or oral, express or implied. This Warranty 
supersedes  and  excludes  any  prior  oral  or  written 
representations or warranties. McCall expressly disclaims 
any  implied  warranties  of  merchantability,  fitness  for  a 
particular purpose or compliance with any law, treaty, rule 
or regulation relating to the Motor-Compressor, and the 
full liability of McCall for any breach of this warranty, will 
be as provided in this warranty.

Other than any applicable McCall Standard One year Limited 
Warranty,  this  McCall  Additional  Four  Year  Protection  Plan 
and any applicable McCall Service Labor Contract, the Original 
Purchaser agrees and acknowledges that no other warranties 
are  offered  or  provided  in  connection  with  or  for  the  Motor-
Compressor or any part thereof.
In  no  event  will  McCall  be  liable  for  special,  incidental  or 
consequential  damages,  or  for  damages  in  the  nature  of 
penalties.

Содержание MCCDRL2-G

Страница 1: ...TRUCTIONS Series I Reach Ins with Aluminum Interior Service Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of dam...

Страница 2: ...OTHER APPLIANCE UNLESSALLCOVERANDACCESSPANELSAREINPLACEANDPROPERLYSECURED DO NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPT...

Страница 3: ...terior of the package an skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that...

Страница 4: ...CC McCall Reach In R Refrigerator F Freezer H Heated D Dual Temp None Reach in PT Pass Thru RL Refrigerator Left TR Top Refrigerator 1 1 Section 2 2 Section 3 3 Section S Solid Full SH Solid Half SLG...

Страница 5: ...tic expansion valve System is controlled using an electronic temperature control which provides improved pull downtimes reducingcompressorcyclingandlongercompressor lifewithlowerenergyconsumption Cont...

Страница 6: ...Amps Storage Capacity Ft3 Shelf Capacity Ft2 No Of Shelves H P BTU HR R 404A Charge Oz Shipping Weight NEMA Plug Energy KWH MCCDTR1 SH Refrigerator 115 14 0 11 52 4 23 2 1 5 1543 10 525lbs 238kg 5 20P...

Страница 7: ...15P 4 58 MCCRPT2 S SH 115 16 0 55 42 27 54 6 1 2 5465 24 700lbs 318kg 5 20P 5 96 MCCRPT2 G GH 115 16 0 55 42 27 54 6 1 2 5465 24 700lbs 318kg 5 20P 8 16 Reach In Hot Food Cabinets Hinged Doors Standa...

Страница 8: ...lift it up and ease it out of the hinge brackets Leg Caster Utility Base Installation Some cabinets may weigh over 1000 pounds 450 kg Use a lifting device capable of supporting the unit when removing...

Страница 9: ...means to satisfy the authority having jurisdiction The power cords supplied with this equipment are three pronged plugs and must be connected to a three pronged wall outlet for proper grounding Do not...

Страница 10: ...rstheevaporatortemperature and will turn off the compressor and condenser fan motor when needed to allow accumulated frost on the evaporator to clear During this defrost cycle the digital temperature...

Страница 11: ...aise the shroud to access the controls Set the Main POWER ON OFF switch to the ON position Adjust the electronic thermostat to the desired tempera ture Allow unit to warm up before use 1 2 3 4 5 The u...

Страница 12: ...begin to breakdown the steel and begin to form discoloration or rust Proper cleaning of stainless steel requires soft cloths or plastic scouring pads NEVER USE STEEL PADS WIRE BRUSHES OR SCRAPERS Cle...

Страница 13: ...rage area restricting the airflow and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature Preventing blower coil corrosion To help...

Страница 14: ...8 34 24 2 9 30 54 7 2 0 5 02 33 2 2 4 23 4 3 42 2 5 4 2 9 02 33 2 4 3 4 8 42 2 9 3 6 2 5 42 4 0 2 452 7 53 30 9 34 24 7 3 2 7 2 5 6 0 2 4 2 53 4 2 6 0 3 3 2 4 2 6 0 3 3 2 7 7 7 7 34 24 2 5 4 2 02 4 4...

Страница 15: ...15 McCall Refrigerator Wiring Diagrams MCCR2 Solid Doors MCCR2 MCCR2 SL Glass Doors...

Страница 16: ...16 McCall Series I Reach In Manual Refrigerator Wiring Diagrams MCCRPT2 MCCR3 Solid Doors MCCRPT2 MCCR3 Glass Doors...

Страница 17: ...9 5 37 4 7 7 7 02 4 4 2 2 9 4 2 2 9 6 0 2 4 2 2 34 4 2 3 2 MCCF1 Solid Doors 30 9 3 2 2 34 4 2 6 0 2 4 2 2 2 6 4 3 0 4 2 8 5 53 3 2 9 3 6 2 37 4 4 2 2 9 02 33 2 2 9 42 4 0 2 452 30 9 53 6 0 3 3 2 3 3...

Страница 18: ...18 McCall Series I Reach In Manual Freezer Wiring Diagrams PDF created with pdfFactory trial version www pdffactory com MCCF2 Solid Doors MCCF2 MCCF3 Glass Doors...

Страница 19: ...19 McCall Freezer Wiring Diagrams MCCF3 Solid Doors MCCDTR1 Solid Doors Refrigerator Freezer Combination Wiring Diagram...

Страница 20: ...20 McCall Series I Reach In Manual MCCH1 MCCH2 MCCH3 Solid Glass Doors Heated Models Wiring Diagram...

Страница 21: ...mpressor Relay Overload Capacitor start Drier filter Motor fan condensor Switch Control switch Blade fan Motor fan evaporator Coil evaporator Coil condenser Blade fan condenser Guard fan condenser Com...

Страница 22: ...0019 Guard Fan Wire 2162716 Motor Fan 16W 115V CW 3516438 Relay Comp Ovld NF7CLX 2190154 Switch Rocker 20A 125V 3516570 Thermometer Digital 3516429 Valve Therm EXP W O MOP MCCRPT1 Glass Doors Part Num...

Страница 23: ...DR 2194953 Limit High Defrost 2162716 Motor Fan 16W 115V CW 2162715 Motor Fan Bay 3 4ST 2194959 Switch Rocker Snap in 3516570 Thermometer Digital MCCF2 Solid Doors Part Number Description 3516433 Blad...

Страница 24: ...6968 Cond Unit 1 5HP 404A REF 2194782KT Control REF Danfoss 2194536 Control Temp In 40D Out 2194046 Fan Delay Defrost Limit 3516173 Guard Plastic Fan 6 3978197 Guard Wire Evaporator 2194659 Heater 115...

Страница 25: ...our Is Allowed To Replace Thermostat Contactor Relay Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch Microproc...

Страница 26: ...ALLS WILL BE BILLED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition...

Страница 27: ...s Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigerat...

Страница 28: ...___ S N ____________________ Installation Date _____________ For a list of McCall s authorized parts depots visit our website at www mccallrefrigeration com 980 S Isabella Rd Mt Pleasant MI 48858 U S...