Standard Labor Guidelines To Repair Or Replace Parts On McCall Equipment

Advice and recommendations given by McCall Service Technicians do not constitute or guarantee any special coverage.

• A maximum of 1-hour is allowed to 

diagnose a defective component

.

• A maximum of 1-hour is allowed for 

retrieval of parts

 not in stock.

• A maximum 

travel distance

 of 100 miles round trip and 2-hours will be reimbursed. 

• Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or 

correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a 

Service Work 

Authorization

 from McCall.  You must submit the number with the service claim.

Labor Of 1-Hour Is Allowed To Replace:

• Thermostat 

•  Contactor/Relay

• Door Jamb Switch 

•  Evaporator/Condenser Fan Motor and Blade

• Solenoid Coil 

•  Circulating Fan Motor and Blade

• Hi-limit/Thermal Protector Switch 

•  Microprocessor Control

• Fan Delay/Defrost Termination Switch 

•  Transformer

• Compressor Start Components and Overload Protector 

•  Door Hinges, Locks, and Gaskets

• Defrost Timer 

•  Condensate Element

• Thermometer

Labor Of 2 Hours To Replace:

• Drawer Tracks/Cartridges 

•  Defrost Element

• Pressure Control 

•  Heating Element

• Solenoid Valve 

•  Locate/Repair Leak

Labor Of 3 Hours To Replace:

• EPR or CPR Valve 

•  Condenser or Evaporator Coil

• Expansion Valve

Labor Of 4 Hours To Replace:

• Compressor
This includes recovery of refrigerant and leak check.
$55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings, 

solder, brazing rod, nitrogen, or similar fees.)

Refrigerants:

• R404A A maximum of $15.00/lb. or $1.00/oz. will be reimbursed.

Содержание MCCDRL2-G

Страница 1: ...TRUCTIONS Series I Reach Ins with Aluminum Interior Service Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of dam...

Страница 2: ...OTHER APPLIANCE UNLESSALLCOVERANDACCESSPANELSAREINPLACEANDPROPERLYSECURED DO NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPT...

Страница 3: ...terior of the package an skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that...

Страница 4: ...CC McCall Reach In R Refrigerator F Freezer H Heated D Dual Temp None Reach in PT Pass Thru RL Refrigerator Left TR Top Refrigerator 1 1 Section 2 2 Section 3 3 Section S Solid Full SH Solid Half SLG...

Страница 5: ...tic expansion valve System is controlled using an electronic temperature control which provides improved pull downtimes reducingcompressorcyclingandlongercompressor lifewithlowerenergyconsumption Cont...

Страница 6: ...Amps Storage Capacity Ft3 Shelf Capacity Ft2 No Of Shelves H P BTU HR R 404A Charge Oz Shipping Weight NEMA Plug Energy KWH MCCDTR1 SH Refrigerator 115 14 0 11 52 4 23 2 1 5 1543 10 525lbs 238kg 5 20P...

Страница 7: ...15P 4 58 MCCRPT2 S SH 115 16 0 55 42 27 54 6 1 2 5465 24 700lbs 318kg 5 20P 5 96 MCCRPT2 G GH 115 16 0 55 42 27 54 6 1 2 5465 24 700lbs 318kg 5 20P 8 16 Reach In Hot Food Cabinets Hinged Doors Standa...

Страница 8: ...lift it up and ease it out of the hinge brackets Leg Caster Utility Base Installation Some cabinets may weigh over 1000 pounds 450 kg Use a lifting device capable of supporting the unit when removing...

Страница 9: ...means to satisfy the authority having jurisdiction The power cords supplied with this equipment are three pronged plugs and must be connected to a three pronged wall outlet for proper grounding Do not...

Страница 10: ...rstheevaporatortemperature and will turn off the compressor and condenser fan motor when needed to allow accumulated frost on the evaporator to clear During this defrost cycle the digital temperature...

Страница 11: ...aise the shroud to access the controls Set the Main POWER ON OFF switch to the ON position Adjust the electronic thermostat to the desired tempera ture Allow unit to warm up before use 1 2 3 4 5 The u...

Страница 12: ...begin to breakdown the steel and begin to form discoloration or rust Proper cleaning of stainless steel requires soft cloths or plastic scouring pads NEVER USE STEEL PADS WIRE BRUSHES OR SCRAPERS Cle...

Страница 13: ...rage area restricting the airflow and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature Preventing blower coil corrosion To help...

Страница 14: ...8 34 24 2 9 30 54 7 2 0 5 02 33 2 2 4 23 4 3 42 2 5 4 2 9 02 33 2 4 3 4 8 42 2 9 3 6 2 5 42 4 0 2 452 7 53 30 9 34 24 7 3 2 7 2 5 6 0 2 4 2 53 4 2 6 0 3 3 2 4 2 6 0 3 3 2 7 7 7 7 34 24 2 5 4 2 02 4 4...

Страница 15: ...15 McCall Refrigerator Wiring Diagrams MCCR2 Solid Doors MCCR2 MCCR2 SL Glass Doors...

Страница 16: ...16 McCall Series I Reach In Manual Refrigerator Wiring Diagrams MCCRPT2 MCCR3 Solid Doors MCCRPT2 MCCR3 Glass Doors...

Страница 17: ...9 5 37 4 7 7 7 02 4 4 2 2 9 4 2 2 9 6 0 2 4 2 2 34 4 2 3 2 MCCF1 Solid Doors 30 9 3 2 2 34 4 2 6 0 2 4 2 2 2 6 4 3 0 4 2 8 5 53 3 2 9 3 6 2 37 4 4 2 2 9 02 33 2 2 9 42 4 0 2 452 30 9 53 6 0 3 3 2 3 3...

Страница 18: ...18 McCall Series I Reach In Manual Freezer Wiring Diagrams PDF created with pdfFactory trial version www pdffactory com MCCF2 Solid Doors MCCF2 MCCF3 Glass Doors...

Страница 19: ...19 McCall Freezer Wiring Diagrams MCCF3 Solid Doors MCCDTR1 Solid Doors Refrigerator Freezer Combination Wiring Diagram...

Страница 20: ...20 McCall Series I Reach In Manual MCCH1 MCCH2 MCCH3 Solid Glass Doors Heated Models Wiring Diagram...

Страница 21: ...mpressor Relay Overload Capacitor start Drier filter Motor fan condensor Switch Control switch Blade fan Motor fan evaporator Coil evaporator Coil condenser Blade fan condenser Guard fan condenser Com...

Страница 22: ...0019 Guard Fan Wire 2162716 Motor Fan 16W 115V CW 3516438 Relay Comp Ovld NF7CLX 2190154 Switch Rocker 20A 125V 3516570 Thermometer Digital 3516429 Valve Therm EXP W O MOP MCCRPT1 Glass Doors Part Num...

Страница 23: ...DR 2194953 Limit High Defrost 2162716 Motor Fan 16W 115V CW 2162715 Motor Fan Bay 3 4ST 2194959 Switch Rocker Snap in 3516570 Thermometer Digital MCCF2 Solid Doors Part Number Description 3516433 Blad...

Страница 24: ...6968 Cond Unit 1 5HP 404A REF 2194782KT Control REF Danfoss 2194536 Control Temp In 40D Out 2194046 Fan Delay Defrost Limit 3516173 Guard Plastic Fan 6 3978197 Guard Wire Evaporator 2194659 Heater 115...

Страница 25: ...our Is Allowed To Replace Thermostat Contactor Relay Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch Microproc...

Страница 26: ...ALLS WILL BE BILLED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition...

Страница 27: ...s Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigerat...

Страница 28: ...___ S N ____________________ Installation Date _____________ For a list of McCall s authorized parts depots visit our website at www mccallrefrigeration com 980 S Isabella Rd Mt Pleasant MI 48858 U S...

Отзывы: