background image

McCall Series I Reach-In Manual

Standard One Year Limited Warranty

 

(One year parts and labor, five year compressor)

McCall warrants to the Original Purchaser of the McCall product (herein 
called the “Unit”) that such Unit, and all parts thereof, will be free from 
defects in material and workmanship under normal use and service 
for a period of one (1) year from the date of shipment of the Unit to the 
Original Purchaser 

or, if the Original Purchaser returns the warranty 

card completely filled out including the date of installation within 
thirty (30) days of receipt of the Unit, one (1) year from the date of 
installation. 

During this one year warranty period, McCall will repair 

or replace any defective part or portion there of returned to McCall by 
the Original Purchaser which McCall determines was defective due to 
faulty material or workmanship. During this one year warranty period, 
McCall will pay labor, crating and freight incurred in the removal of the 
Unit or defective component and shipment to McCall. Reimbursement 
is subject to the following limitations: A maximum of 1-hour is allowed to 
diagnose a defective component; A maximum of 1-hour is allowed for 
retrieval of parts not in stock; A maximum travel distance of 100 miles 
round trip and 2-hours will be reimbursed. Overtime, installation/start-
up, normal control adjustments, general maintenance, glass breakage, 
freight damage, and/or correcting an end-user installation error will not 
be reimbursed under warranty unless pre-approved with a Service Work 
Authorization from McCall. McCall will pay the return costs if the Unit 
or part thereof was defective.
The term “Original Purchaser” as used herein means that person, firm, 
association, or corporation for whom the Unit was originally installed.
This  warranty  does  not  apply  to  any  Unit  or  part  thereof  that  has 
been  subjected  to  misuse,  neglect,  alteration,  or  accident,  such  as 
accidental  damage  to  the  exterior  finish,  operated  contrary  to  the 
recommendations specified by McCall; or repaired or altered by anyone 
other than McCall in any way so as to, in McCall’s sole judgment, affect 
its quality or efficiency. This warranty does not apply to any Unit that 
has been moved from the location where it was originally installed. 
This  warranty  also  does  not  cover  the  refrigerator  drier  or  the  light 
bulbs used in the Unit. 

The warranty is subject to the user’s normal 

maintenance and care responsibility as set forth in the Service and 
Installation Manual, such as cleaning the condenser coil, and is 
in lieu of all other obligations of McCall. McCall neither assumes, 
nor authorizes any other person to assume for McCall, any other 
liability in connection with McCall’s products.

Removal or defacement of the original Serial Number or Model Number 
from any Unit shall be deemed to release McCall from all obligations 
hereunder or any other obligations, express or implied.
Parts  furnished  by  suppliers  to  McCall  are  guaranteed  by  McCall 
only to the extent of the original manufacturer’s express warranty to 
McCall. Failure of the Original Purchaser to receive such manufacturers 
warranty shall in no way create any warranty, expressed or implied, or 
any other obligation or liability on McCall’s part in respect thereof.

IF THE CUSTOMER IS USING A PART THAT RESULTS IN A VOIDED 
WARRANTY  AND  A  McCall  AUTHORIZED  REPRESENTATIVE 
TRAVELS  TO  THE  INSTALLATION  ADDRESS  TO  PERFORM 
WARRANTY SERVICE, THE SERVICE REPRESENTATIVE WILL 
ADVISE CUSTOMER THE WARRANTY IS VOID. SUCH SERVICE 
CALLS WILL BE BILLED TO CUSTOMER AT THE AUTHORIZED 
SERVICE CENTER’S THEN APPLICABLE TIME AND MATERIALS 
RATES.  CONSIDER:  CUSTOMER  MAY  INITIATE  A  SERVICE 
AGREEMENT WITHOUT PARTS COVERAGE.

Under no condition does this warranty give the Original Purchaser the 
right to replace the defective Unit with a complete Unit of the same 
manufacturer  or  of  another  make.  Unless  authorized  by  McCall  in 
writing,  this  warranty  does  not  permit  the  replacement  of  any  part, 
including the motor-compressor, to be made with the part of another 
make or manufacturer.

If shipment of a replacement part is requested prior to the arrival in 
the  McCall  factory  of  the  part  claimed  to  be  defective,  the  Original 
Purchaser must accept delivery of the replacement part on a C.O.D. 
basis, with credit being issued after the part has been received and 
inspected  at  McCall’s  plant  and  determined  by  McCall  to  be  within 
this warranty.
No claims can be made under this warranty for spoilage of any products 
for any reason, including system failure.
The  installation  contractor  shall  be  responsible  for  building  access, 
entrance and field conditions to insure sufficient clearance to allow any 
hood(s), vent(s), or Unit(s) if necessary, to be brought into the building. 
McCall  will  not  be  responsible  for  structural  changes  or  damages 
incurred during installation of the Unit or any exhaust system.
McCall shall not be liable in any manner for any default or delay in 
performance hereunder caused by or resulting from any contingency 
beyond McCall’s control, including, but not limited to, war, governmental 
restrictions or restraints, strike, lockouts, injunctions, fire, flood, acts 
of nature, short or reduced supply of raw materials, or discontinuance 
of the parts by the original part manufacturer.

The  Service  Labor  Contract,  if  applicable,  the  foregoing  is 
exclusive and in lieu of all other warranties, whether written or 
oral, express or implied. This warranty supersedes and excludes 
any  prior  oral  or  written  representations  or  warranties.  McCall 
expressly disclaims any implied warranties of merchantability, 
fitness for a particular purpose, or compliance with any law, treaty, 
rule  or  regulation  relating  to  the  discharge  of  substances  into 
the environment. The sole and exclusive remedies of any person 
relating to the Unit, and the full liability of McCall for any breach 
of this warranty, will be as provided in this warranty.

Other  than  this  McCall  Standard  One  Year  Limited  Warranty,  any 
applicable McCall Additional Three Year Protection Plan or applicable 
McCall  Service  Labor  Contract,  the  Original  Purchaser  agrees  and 
acknowledges  that  no  other  warranties  are  offered  or  provided  in 
connection with or for the Unit or any other part thereof.
In no event will McCall be liable for special, incidental or consequential 
damages, or for damages in the nature of penalties.

IF DURING THE WARRANTY PERIOD, CUSTOMER USES A PART 
FOR THIS McCall EQUIPMENT OTHER THAN AN UNMODIFIED 
NEW  OR  RECYCLED  PART  PURCHASED  DIRECTLY  FROM 
McCall  OR  ANY  OF  ITS  AUTHORIZED  SERVICE  CENTERS 
AND/OR  THE  PART  BEING  USED  IS  MODIFIED  FROM  ITS 
ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. 
FURTHER, McCall AND ITS AFFILIATES WILL NOT BE LIABLE 
FOR ANY CLAIMS DAMAGES OR EXPENSES INCURRED BY THE 
CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE 
OR  IN  PART,  DUE  TO  THE  INSTALLATION  OF  ANY  MODIFIED 
PART  AND/OR  PART  RECEIVED  FROM  AN  UNAUTHORIZED 
SERVICE CENTER. If the warranty becomes void, Customer may 
purchase from McCall, if available, a Service Agreement or service 
at the then current time and materials rate.

For more information on McCall warranty’s log on and check out the 
service section of our web site at www.mccallrefrigeration.com.

Содержание MCCDRL2-G

Страница 1: ...TRUCTIONS Series I Reach Ins with Aluminum Interior Service Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of dam...

Страница 2: ...OTHER APPLIANCE UNLESSALLCOVERANDACCESSPANELSAREINPLACEANDPROPERLYSECURED DO NOT OPERATE THIS EQUIPMENT DAMP OR WET HANDS MAY STICK TO COLD SURFACES ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPT...

Страница 3: ...terior of the package an skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that...

Страница 4: ...CC McCall Reach In R Refrigerator F Freezer H Heated D Dual Temp None Reach in PT Pass Thru RL Refrigerator Left TR Top Refrigerator 1 1 Section 2 2 Section 3 3 Section S Solid Full SH Solid Half SLG...

Страница 5: ...tic expansion valve System is controlled using an electronic temperature control which provides improved pull downtimes reducingcompressorcyclingandlongercompressor lifewithlowerenergyconsumption Cont...

Страница 6: ...Amps Storage Capacity Ft3 Shelf Capacity Ft2 No Of Shelves H P BTU HR R 404A Charge Oz Shipping Weight NEMA Plug Energy KWH MCCDTR1 SH Refrigerator 115 14 0 11 52 4 23 2 1 5 1543 10 525lbs 238kg 5 20P...

Страница 7: ...15P 4 58 MCCRPT2 S SH 115 16 0 55 42 27 54 6 1 2 5465 24 700lbs 318kg 5 20P 5 96 MCCRPT2 G GH 115 16 0 55 42 27 54 6 1 2 5465 24 700lbs 318kg 5 20P 8 16 Reach In Hot Food Cabinets Hinged Doors Standa...

Страница 8: ...lift it up and ease it out of the hinge brackets Leg Caster Utility Base Installation Some cabinets may weigh over 1000 pounds 450 kg Use a lifting device capable of supporting the unit when removing...

Страница 9: ...means to satisfy the authority having jurisdiction The power cords supplied with this equipment are three pronged plugs and must be connected to a three pronged wall outlet for proper grounding Do not...

Страница 10: ...rstheevaporatortemperature and will turn off the compressor and condenser fan motor when needed to allow accumulated frost on the evaporator to clear During this defrost cycle the digital temperature...

Страница 11: ...aise the shroud to access the controls Set the Main POWER ON OFF switch to the ON position Adjust the electronic thermostat to the desired tempera ture Allow unit to warm up before use 1 2 3 4 5 The u...

Страница 12: ...begin to breakdown the steel and begin to form discoloration or rust Proper cleaning of stainless steel requires soft cloths or plastic scouring pads NEVER USE STEEL PADS WIRE BRUSHES OR SCRAPERS Cle...

Страница 13: ...rage area restricting the airflow and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature Preventing blower coil corrosion To help...

Страница 14: ...8 34 24 2 9 30 54 7 2 0 5 02 33 2 2 4 23 4 3 42 2 5 4 2 9 02 33 2 4 3 4 8 42 2 9 3 6 2 5 42 4 0 2 452 7 53 30 9 34 24 7 3 2 7 2 5 6 0 2 4 2 53 4 2 6 0 3 3 2 4 2 6 0 3 3 2 7 7 7 7 34 24 2 5 4 2 02 4 4...

Страница 15: ...15 McCall Refrigerator Wiring Diagrams MCCR2 Solid Doors MCCR2 MCCR2 SL Glass Doors...

Страница 16: ...16 McCall Series I Reach In Manual Refrigerator Wiring Diagrams MCCRPT2 MCCR3 Solid Doors MCCRPT2 MCCR3 Glass Doors...

Страница 17: ...9 5 37 4 7 7 7 02 4 4 2 2 9 4 2 2 9 6 0 2 4 2 2 34 4 2 3 2 MCCF1 Solid Doors 30 9 3 2 2 34 4 2 6 0 2 4 2 2 2 6 4 3 0 4 2 8 5 53 3 2 9 3 6 2 37 4 4 2 2 9 02 33 2 2 9 42 4 0 2 452 30 9 53 6 0 3 3 2 3 3...

Страница 18: ...18 McCall Series I Reach In Manual Freezer Wiring Diagrams PDF created with pdfFactory trial version www pdffactory com MCCF2 Solid Doors MCCF2 MCCF3 Glass Doors...

Страница 19: ...19 McCall Freezer Wiring Diagrams MCCF3 Solid Doors MCCDTR1 Solid Doors Refrigerator Freezer Combination Wiring Diagram...

Страница 20: ...20 McCall Series I Reach In Manual MCCH1 MCCH2 MCCH3 Solid Glass Doors Heated Models Wiring Diagram...

Страница 21: ...mpressor Relay Overload Capacitor start Drier filter Motor fan condensor Switch Control switch Blade fan Motor fan evaporator Coil evaporator Coil condenser Blade fan condenser Guard fan condenser Com...

Страница 22: ...0019 Guard Fan Wire 2162716 Motor Fan 16W 115V CW 3516438 Relay Comp Ovld NF7CLX 2190154 Switch Rocker 20A 125V 3516570 Thermometer Digital 3516429 Valve Therm EXP W O MOP MCCRPT1 Glass Doors Part Num...

Страница 23: ...DR 2194953 Limit High Defrost 2162716 Motor Fan 16W 115V CW 2162715 Motor Fan Bay 3 4ST 2194959 Switch Rocker Snap in 3516570 Thermometer Digital MCCF2 Solid Doors Part Number Description 3516433 Blad...

Страница 24: ...6968 Cond Unit 1 5HP 404A REF 2194782KT Control REF Danfoss 2194536 Control Temp In 40D Out 2194046 Fan Delay Defrost Limit 3516173 Guard Plastic Fan 6 3978197 Guard Wire Evaporator 2194659 Heater 115...

Страница 25: ...our Is Allowed To Replace Thermostat Contactor Relay Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch Microproc...

Страница 26: ...ALLS WILL BE BILLED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE Under no condition...

Страница 27: ...s Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigerat...

Страница 28: ...___ S N ____________________ Installation Date _____________ For a list of McCall s authorized parts depots visit our website at www mccallrefrigeration com 980 S Isabella Rd Mt Pleasant MI 48858 U S...

Отзывы: