8. Operating anomalies
In the event of problems with functioning
, carry out these simple controls to check if repairs are needed.
If the problem still remains after carrying out the suggested controls, consult your
local dealer or contact
MC elettronica
Technical Service.
ANOMALY
CAUSE
REMEDY
The Computer does
not switch on
a. The power cable is
disconnected
a. Check the power cable
The
quantity
of
product
distributed
(Kg/Ha) display is not
constant
a. Speed detected by
the Computer is not
constant (check the
display)
a. Check the electric
connections and the
mechanic position of the
speed sensor
b. The Computer
constantly opens and
closes the actuators
b.
Decrease the “dP”
parameter value set (see
section “
on page 25) or carry out
again the procedure for
calibrating the actuators
(see section “
” on
The quantity of
product distributed
displayed is constant
but does not
correspond to the real
quantity distributed
a. The product type
chosen into parameter
“P” is not correct
a.
See chapter “
b. Calibration of
parameters 1A, 1b
etc. is not correct
b. See reference paragraph
(chapter “
on page 25)