background image

Operating Instructions MBA888 

Operating Instructions MBA888 

11/2017/Item No. 8001705 

Page 5/6

 

MBA Instruments GmbH 

[email protected] 

9.

 

Maintenance 

The MBA888 is maintenance-free. Nevertheless, you should regularly check proper functioning of the device at least 

once per annum. 

 

 

10.

 

Operating data 

 

MBA888 24 V DC 

MBA888 12 V DC 

115 V… 230 V AC 

Operating 

voltage: 

24 V DC 

12 V DC 

115 V … 230 V AC 

Current 

consumption: 

max. 90 mA 

(not including output load) 

max. 120 mA 

not including output 

load) 

6 VA 

Signal: 

24/0 V DC max. 1.2 A 

12/0 V DC max. 1.2 A 

Floating changeover contact max. 6 A 

Connection 

cable: 

LAPP Ölflex Robust 210 5 G 0.5 mm

Standard length: 2 m  

(other lengths on request)

 

LAPP Ölflex Robust 210 7 G 0.75 mm

Standard length: 2 m  

(other lengths on request) 

 

 

  With ATEX: 

 

 

 

 

 

Without ATEX:   

Temperature in container:-20 to +80°C 

 

 

Temperature in container:-30 to +80°C 

Ambient temperature:  -20 to +55°C 

 

 

Ambient temperature:  -30 to +60°C 

Ambient pressure: 

0.8 to +1 bar 

 

 

Ambient pressure: 

0.8 to +3 bar 

 
Housing enclosure: IP65 – Water-tight and dust-tight 
 
Seals and gaskets:  VITON and PTFE gasket  

 

Motor shaft with additional seal (VITON) 

Process connection 

Housing: 

Aluminium or stainless steel 1.4305 

Switching time 

 

Standard 

Quick 

Switch 

if shaft blocked: 

6 s 

1 s 

if shaft not blocked: 

3 s 

1 s 

 

Device marking 

Ex marking: 

 

II 1/2 D   Ex ta/tb IIIC T100°C Da/Db 

 

Type-Examination Certificate: ZELM 15 ATEX 0547 X 

 

11.

 

Rating plate (example) 

 

 

 

 

 

 

 

Serial number: 

Please always specify 

when submitting 

queries/enquiries 

 

 

 

 

 

 

 

 

 

Содержание MBA888

Страница 1: ...88 Level Switch for Bulk Goods Installation and Operation MBA Instruments GmbH Friedrich List Straße 3 7 D 25451 Quickborn GERMANY Phone 49 4106 123 888 80 info mba instruments de www mba instruments de EN ...

Страница 2: ...sponsibility Use the device only as described in these Operating Instructions The manufacturer is unable to assume any liability or warranty for other uses Follow all local legislation technical regulations and in company directives applicable to the device s place of use in addition to these Operating Instructions The housing cannot be opened Comply with the voltage and temperature specifications...

Страница 3: ...ess connection The installation position must be selected such that the vane at the end of the shaft is covered by the bulk material at the switching point Light weight or fluid bulk material must cover the vane a little more than is the case with heavy bulk material Measurement is independent of the MBA888 s installation position 2 Shaft stops 3 Shaft turns CW 4 Shaft stops Signal switches full 1...

Страница 4: ...DC 10 12 V DC 10 2 GND 0 V 0 V 3 Shaft Blocked signal Container full 24V 0 V max 1 2 A 12V 0 V max 1 2A 4 Shaft rotating signal Container empty 24 V 0 V max 1 2 A 12 V 0 V max 1 2 A GN YE PE wire 8 Electrical connection MBA888 115 230 V AC The MBA888 is supplied with a ready to use cable The flexible leads at the end of the cable are numbered 1 to 6 and must be connected in a suitable terminal com...

Страница 5: ...andard length 2 m other lengths on request LAPP Ölflex Robust 210 7 G 0 75 mm 2 Standard length 2 m other lengths on request With ATEX Without ATEX Temperature in container 20 to 80 C Temperature in container 30 to 80 C Ambient temperature 20 to 55 C Ambient temperature 30 to 60 C Ambient pressure 0 8 to 1 bar Ambient pressure 0 8 to 3 bar Housing enclosure IP65 Water tight and dust tight Seals an...

Страница 6: ...Instructions MBA888 11 2017 Item No 8001705 Page 6 6 MBA Instruments GmbH info mba instruments de MBA Instruments GmbH Friedrich List Straße 3 7 25451 Quickborn GERMANY Telefon 49 4106 123 888 80 info mba instruments de www mba instruments de ...

Отзывы: